Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
HTML |
---|
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric3/lastSuccessfulBuild/artifact/SRSwitchFailure_onos-2.2_20-builds_graph.jpg", alt="SRSwitchFailure", style="width:525px;height:350px;border:0"> |
commit cf3284174edba18f921995fe01fb0e5f802caf7e 18ad45bfc79f02d01226a47a7367d850a06335eb (HEAD -] onos-2.2, origin/onos-2.2)
Author: Andrea Campanella [andrea@opennetworking.orgONOS Jenkins User [jenkins@onlab.us]
AuthorDate: Wed Fri Oct 7 16 07:4427:21 30 2020 +02000000
Commit: Andrea Campanella [andrea@opennetworking.orgONOS Jenkins User [jenkins@onlab.us]
CommitDate: Fri Oct 9 16 07:3527:10 30 2020 +0000
[ONOS-8121][VOL-3259] Fixing null filter for felix fileinstall
Starting snapshot 2.2.7-SNAPSHOT
Case 1: Switch Failure test with 2x2 Leaf-spine and 1 Onos - FAIL
...
- 2.1 Apply cell to environment - PASS
- 2.2 Uninstalling Atomix - PASS
- 2.3 Uninstalling ONOS package - PASS
- 2.4 Creating ONOS package - PASS
- 2.5 Installing Atomix - PASS
- 2.6 Installing ONOS package - PASS
- 2.7 Set up ONOS secure SSH - PASS
- 2.8 Checking ONOS service - PASS
- 2.9 Starting ONOS CLI sessions - PASS
- 2.10 Checking ONOS nodes - PASS
- 2.11 Checking ONOS applications - PASS
- 2.12 Set logging levels - PASS
- 2.13 Set ONOS configurations - PASS
- 2.14 Starting Mininet Topology - PASS
- 2.15 Check whether the flow count is bigger than 350 - PASS
- 2.16 Check whether all flow status are ADDED - PASS
- 2.17 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2 - PASS FAIL
- IP connectivity failed
- 2.18 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2 - FAIL
- IP connectivity failed
- 2.19 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2 - FAIL
- IP connectivity failed
- 2.20 Kill ['spine101'] - PASS
- 2.21 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2_Failure - PASS FAIL
- IP connectivity failed
- 2.22 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_Failure - FAIL
- IP connectivity failed
- 2.23 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_Failure - FAIL
- IP connectivity failed
- 2.24 Recovering ['spine101'] - PASS
- 2.25 Check whether the flow count is bigger than 350 - PASS
- 2.26 Check whether all flow status are ADDED - PASS
- 2.27 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2_Recovery - PASS FAIL
- IP connectivity failed
- 2.28 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_Recovery - FAIL
- IP connectivity failed
- 2.29 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_Recovery - FAIL
- IP connectivity failed
- 2.30 Stopping Mininet - PASS
- 2.31 Copying karaf logs - PASS
...