Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric4/lastSuccessfulBuild/artifact/SRSwitchFailure_master_20-builds_graph.jpg", alt="SRSwitchFailure", style="width:525px;height:350px;border:0">

commit d14f1a3f22a212ae2a0f5e97fa416264a1c5903d 13a72357d151b567e0e2678f376f7a68642ef8e9 (HEAD -] master, origin/master, origin/HEAD)
Author: Yi Tseng pierventre [yi@opennetworkingpier@opennetworking.org]
AuthorDate: Tue Oct 13 1927 16:1508:12 48 2020 -0700+0100
Commit: Yi Tseng pierventre [yi@opennetworkingpier@opennetworking.org]
CommitDate: Fri Thu Oct 23 0129 11:0937:40 46 2020 -0700
Support install IntIntents to device with postcard mode+0100

[ONOS-8123] Fix an issue related to the component properties.

Case 1: Switch Failure test with 2x2 Leaf-spine and 1 Onos - FAIL

...

  • 5.1 Apply cell to environment - PASS (tick)
  • 5.2 Uninstalling Atomix - PASS (tick)
  • 5.3 Uninstalling ONOS package - PASS (tick)
  • 5.4 Creating ONOS package - PASS (tick)
  • 5.5 Installing Atomix - PASS (tick)
  • 5.6 Installing ONOS package - PASS (tick)
  • 5.7 Set up ONOS secure SSH - PASS (tick)
  • 5.8 Checking ONOS service - PASS (tick)
  • 5.9 Starting ONOS CLI sessions - PASS (tick)
  • 5.10 Checking ONOS nodes - PASS (tick)
  • 5.11 Checking ONOS applications - PASS (tick)
  • 5.12 Set logging levels - PASS (tick)
  • 5.13 Set ONOS configurations - PASS (tick)
  • 5.14 Starting Mininet Topology - PASS (tick)
  • 5.15 Check whether the flow count is bigger than 350 - PASS (tick)
  • 5.16 Check whether all flow status are ADDED - PASS (tick)
  • 5.17 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE5 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 5.18 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE5 - FAIL (error)
    • IP connectivity failed
  • 5.19 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE5 - FAIL (error)
    • IP connectivity failed
  • 5.20 Kill ['spine101'] - PASS (tick)
  • 5.21 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE5_Failure - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 5.22 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE5_Failure - FAIL (error)
    • IP connectivity failed
  • 5.23 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE5_Failure - FAIL (error)
    • IP connectivity failed
  • 5.24 Recovering ['spine101'] - PASS (tick)
  • 5.25 Check whether the flow count is bigger than 350 - PASS (tick)
  • 5.26 Check whether all flow status are ADDED - PASS (tick)
  • 5.27 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE5_Recovery - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 5.28 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE5_Recovery - FAIL (error)
    • IP connectivity failed
  • 5.29 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE5_Recovery - FAIL (error)
    • IP connectivity failed
  • 5.30 Stopping Mininet - PASS (tick)
  • 5.31 Copying karaf logs - PASS (tick)