Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
HTML |
---|
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric2/lastSuccessfulBuild/artifact/SRBridging_onos-2.5_20-builds_graph.jpg", alt="SRBridging", style="width:525px;height:350px;border:0"> |
commit a465c31a476f79843d7e502a0e944439bd860952 f7489d7de016ee9953dbe9ac5a7b9da82829111c (HEAD -] onos-2.5, origin/onos-2.5)
Author: Daniele Moro [daniele@opennetworking.orgONOS Jenkins User [jenkins@onlab.us]
AuthorDate: Wed May 19 12:52:45 2021 +0200Mon Sep 20 07:54:42 2021 +0000
Commit: Daniele Moro [daniele@opennetworking.orgONOS Jenkins User [jenkins@onlab.us]
CommitDate: Thu May Mon Sep 20 1707:1854:06 42 2021 +0200
Fix typo on readme0000
Starting snapshot 2.5.4-SNAPSHOT
Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR, ovs switches and 3 ONOS instances - PASS
...
- 5.1 Constructing test variables - PASS
- 5.2 Apply cell to environment - PASS
- 5.3 Uninstalling Atomix - PASS
- 5.4 Uninstalling ONOS package - PASS
- 5.5 Creating ONOS package - PASS
- 5.6 Installing Atomix - PASS
- 5.7 Installing ONOS package - PASS
- 5.8 Set up ONOS secure SSH - PASS
- 5.9 Checking ONOS service - PASS
- 5.10 Starting ONOS CLI sessions - PASS
- 5.11 Checking ONOS nodes - PASS
- 5.12 Checking ONOS applications - PASS
- 5.13 Set logging levels - PASS
- 5.14 Set ONOS configurations - PASS
- 5.15 Starting Mininet Topology - PASS
- 5.16 Check whether the flow count is bigger than 28 - PASS
- 5.17 Check whether all flow status are ADDED - PASS
- 5.18 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS
- 5.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE5 - PASS
- 5.20 Stopping Mininet - PASS
- 5.21 Copying karaf logs - PASS
Case 6: Bridging test between two untagged hosts on vlan-untagged port, with dual-homed ToR, ovs switches and 3 ONOS instances -
...
FAIL
- 6.1 Apply cell to environment - PASS
- 6.2 Uninstalling Atomix - PASS
- 6.3 Uninstalling ONOS package - PASS
- 6.4 Installing Atomix - PASS
- 6.5 Installing ONOS package - PASS
- 6.6 Set up ONOS secure SSH - PASS
- 6.7 Checking ONOS service - PASS
- 6.8 Starting ONOS CLI sessions - PASS
- 6.9 Checking ONOS nodes - PASS
- 6.10 Checking ONOS applications - PASS
- 6.11 Set logging levels - PASS
- 6.12 Set ONOS configurations - PASS
- 6.13 Starting Mininet Topology - PASS
- 6.14 Check whether the flow count is bigger than 74 - PASS FAIL
- Flow count looks wrong; found 37, expecting at least 74
- 6.15 Check whether all flow status are ADDED - PASS
- 6.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 6.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 6.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE6 - PASS
- 6.19 Stopping Mininet - PASS
- 6.20 Copying karaf logs - PASS
...
- 17.1 Apply cell to environment - PASS
- 17.2 Uninstalling Atomix - PASS
- 17.3 Uninstalling ONOS package - PASS
- 17.4 Installing Atomix - PASS
- 17.5 Installing ONOS package - PASS
- 17.6 Set up ONOS secure SSH - PASS
- 17.7 Checking ONOS service - PASS
- 17.8 Starting ONOS CLI sessions - PASS
- 17.9 Checking ONOS nodes - PASS
- 17.10 Checking ONOS applications - PASS
- 17.11 Set logging levels - PASS
- 17.12 Set ONOS configurations - PASS
- 17.13 Starting Mininet Topology - PASS
- 17.14 Check whether the flow count is bigger than 74 - PASS
- 17.15 Check whether all flow status are ADDED - PASS
- 17.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 17.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 17.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE17 - PASS
- 17.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE17 - PASS
- 17.20 Stopping Mininet - PASS
- 17.21 Copying karaf logs - PASS
Case 18: Bridging test between two tagged hosts, with 2x4 dual-homed leaf-spine topology, ovs switches and 3 ONOS instances -
...
FAIL
- 18.1 Apply cell to environment - PASS
- 18.2 Uninstalling Atomix - PASS
- 18.3 Uninstalling ONOS package - PASS
- 18.4 Installing Atomix - PASS
- 18.5 Installing ONOS package - PASS
- 18.6 Set up ONOS secure SSH - PASS
- 18.7 Checking ONOS service - PASS
- 18.8 Starting ONOS CLI sessions - PASS
- 18.9 Checking ONOS nodes - PASS
- 18.10 Checking ONOS applications - PASS
- 18.11 Set logging levels - PASS
- 18.12 Set ONOS configurations - PASS
- 18.13 Starting Mininet Topology - PASS
- 18.14 Check whether the flow count is bigger than 212 - PASS
- 18.15 Check whether all flow status are ADDED - PASS
- 18.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 18.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 18.18 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS FAIL
- Flow count looks wrong: 18
- 18.19 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS
- 18.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE18 - PASS
- 18.21 Verify full connectivity for [u'h3', u'h4'] with tag CASE18 - PASS
- 18.22 Stopping Mininet - PASS
- 18.23 Copying karaf logs - PASS
...
- 36.1 Apply cell to environment - PASS
- 36.2 Uninstalling Atomix - PASS
- 36.3 Uninstalling ONOS package - PASS
- 36.4 Installing Atomix - PASS
- 36.5 Installing ONOS package - PASS
- 36.6 Set up ONOS secure SSH - PASS
- 36.7 Checking ONOS service - PASS
- 36.8 Starting ONOS CLI sessions - PASS
- 36.9 Checking ONOS nodes - PASS
- 36.10 Checking ONOS applications - PASS
- 36.11 Set logging levels - PASS
- 36.12 Set ONOS configurations - PASS
- 36.13 Starting Mininet Topology - PASS
- 36.14 Check whether the flow count is bigger than 74 - PASS FAIL
- Flow count looks wrong; found 34, expecting at least 74
- 36.15 Check whether all flow status are ADDED - FAIL Flow status is wrong!
- PASS
- 36.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - FAIL
- Flow count looks wrong: 27
- PASS
- 36.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 36.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE36 - FAIL
- IP connectivity failed
- PASS
- 36.19 Stopping Mininet - PASS
- 36.20 Copying karaf logs - PASS
Case 37: Bridging test between two untagged hosts, one on vlan-untagged port and the other on vlan-native port, with 2x2 leaf-spine topology, ovs switches and 3 ONOS instances -
...
PASS
- 37.1 Apply cell to environment - PASS
- 37.2 Uninstalling Atomix - PASS
- 37.3 Uninstalling ONOS package - PASS
- 37.4 Installing Atomix - PASS
- 37.5 Installing ONOS package - PASS
- 37.6 Set up ONOS secure SSH - PASS
- 37.7 Checking ONOS service - PASS
- 37.8 Starting ONOS CLI sessions - PASS
- 37.9 Checking ONOS nodes - PASS
- 37.10 Checking ONOS applications - PASS
- 37.11 Set logging levels - PASS
- 37.12 Set ONOS configurations - PASS
- 37.13 Starting Mininet Topology - PASS
- 37.14 Check whether the flow count is bigger than 74 - PASS
- 37.15 Check whether all flow status are ADDED - PASS
- 37.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 37.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 37.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE37 - FAIL
- IP connectivity failed
- PASS
- 37.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE37 - PASS
- 37.20 Stopping Mininet - PASS
- 37.21 Copying karaf logs - PASS
...
- 38.1 Apply cell to environment - PASS
- 38.2 Uninstalling Atomix - PASS
- 38.3 Uninstalling ONOS package - PASS
- 38.4 Installing Atomix - PASS
- 38.5 Installing ONOS package - PASS
- 38.6 Set up ONOS secure SSH - PASS
- 38.7 Checking ONOS service - PASS
- 38.8 Starting ONOS CLI sessions - PASS
- 38.9 Checking ONOS nodes - PASS
- 38.10 Checking ONOS applications - PASS
- 38.11 Set logging levels - PASS
- 38.12 Set ONOS configurations - PASS
- 38.13 Starting Mininet Topology - PASS
- 38.14 Check whether the flow count is bigger than 212 - PASS FAIL
- Flow count looks wrong; found 104, expecting at least 212
- 38.15 Check whether all flow status are ADDED - PASS
- 38.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 38.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 38.18 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS
- 38.19 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS
- 38.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE38 - FAIL
- IP connectivity failed
- PASS
- 38.21 Verify full connectivity for [u'h3', u'h4'] with tag CASE38 - PASS
- 38.22 Stopping Mininet - PASS
- 38.23 Copying karaf logs - PASS
...
- 45.1 Apply cell to environment - PASS
- 45.2 Uninstalling Atomix - PASS
- 45.3 Uninstalling ONOS package - PASS
- 45.4 Installing Atomix - PASS
- 45.5 Installing ONOS package - PASS
- 45.6 Set up ONOS secure SSH - PASS
- 45.7 Checking ONOS service - PASS
- 45.8 Starting ONOS CLI sessions - PASS
- 45.9 Checking ONOS nodes - PASS
- 45.10 Checking ONOS applications - PASS
- 45.11 Set logging levels - PASS
- 45.12 Set ONOS configurations - PASS
- 45.13 Starting Mininet Topology - PASS
- 45.14 Check whether the flow count is bigger than 28 - PASS
- 45.15 Check whether all flow status are ADDED - PASS
- 45.16 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS
- 45.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE45 - PASS
- 45.18 Stopping Mininet - PASS
- 45.19 Copying karaf logs - PASS
Case 46: Bridging test between untagged host and tagged host, with dual-homed ToR, ovs switches and 3 ONOS instances -
...
FAIL
- 46.1 Apply cell to environment - PASS
- 46.2 Uninstalling Atomix - PASS
- 46.3 Uninstalling ONOS package - PASS
- 46.4 Installing Atomix - PASS
- 46.5 Installing ONOS package - PASS
- 46.6 Set up ONOS secure SSH - PASS
- 46.7 Checking ONOS service - PASS
- 46.8 Starting ONOS CLI sessions - PASS
- 46.9 Checking ONOS nodes - PASS
- 46.10 Checking ONOS applications - PASS
- 46.11 Set logging levels - PASS
- 46.12 Set ONOS configurations - PASS
- 46.13 Starting Mininet Topology - PASS
- 46.14 Check whether the flow count is bigger than 74 - PASS FAIL
- Flow count looks wrong; found 34, expecting at least 74
- 46.15 Check whether all flow status are ADDED - PASS
- 46.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 46.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 46.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE46 - PASS
- 46.19 Stopping Mininet - PASS
- 46.20 Copying karaf logs - PASS
Case 47: Bridging test between untagged host and tagged host, with 2x2 leaf-spine topology, ovs switches and 3 ONOS instances -
...
FAIL
- 47.1 Apply cell to environment - PASS
- 47.2 Uninstalling Atomix - PASS
- 47.3 Uninstalling ONOS package - PASS
- 47.4 Installing Atomix - PASS
- 47.5 Installing ONOS package - PASS
- 47.6 Set up ONOS secure SSH - PASS
- 47.7 Checking ONOS service - PASS
- 47.8 Starting ONOS CLI sessions - PASS
- 47.9 Checking ONOS nodes - PASS
- 47.10 Checking ONOS applications - PASS
- 47.11 Set logging levels - PASS
- 47.12 Set ONOS configurations - PASS
- 47.13 Starting Mininet Topology - PASS
- 47.14 Check whether the flow count is bigger than 74 - PASS
- 47.15 Check whether all flow status are ADDED - PASS FAIL
- Flow status is wrong!
- 47.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 47.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 47.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE47 - PASS
- 47.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE47 - PASS
- 47.20 Stopping Mininet - PASS
- 47.21 Copying karaf logs - PASS
...