Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric2/lastSuccessfulBuild/artifact/SRBridging_onos-2.5_20-builds_graph.jpg", alt="SRBridging", style="width:525px;height:350px;border:0">

commit b784d9817744798adbeb97948c33bbd09e72e0ca f7489d7de016ee9953dbe9ac5a7b9da82829111c (HEAD -] onos-2.5, origin/onos-2.5)
Author: Daniele Moro [daniele@opennetworking.orgONOS Jenkins User [jenkins@onlab.us]
AuthorDate: Fri May 21 17:08:29 2021 +0200
Commit: Pier Luigi Ventre [pier@opennetworking.org]
CommitDate: Tue May 25 13:07:31 2021 +0000
Fix onos-dependencies snapshots artifacts upload
--
(cherry picked from commit 385cdd7b6302a09fe09a6843127e6c60273123c4)
Mon Sep 20 07:54:42 2021 +0000
Commit: ONOS Jenkins User [jenkins@onlab.us]
CommitDate: Mon Sep 20 07:54:42 2021 +0000

Starting snapshot 2.5.4-SNAPSHOT

Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR, ovs switches and 3 ONOS instances - PASS

...

  • 5.1 Constructing test variables - PASS (tick)
  • 5.2 Apply cell to environment - PASS (tick)
  • 5.3 Uninstalling Atomix - PASS (tick)
  • 5.4 Uninstalling ONOS package - PASS (tick)
  • 5.5 Creating ONOS package - PASS (tick)
  • 5.6 Installing Atomix - PASS (tick)
  • 5.7 Installing ONOS package - PASS (tick)
  • 5.8 Set up ONOS secure SSH - PASS (tick)
  • 5.9 Checking ONOS service - PASS (tick)
  • 5.10 Starting ONOS CLI sessions - PASS (tick)
  • 5.11 Checking ONOS nodes - PASS (tick)
  • 5.12 Checking ONOS applications - PASS (tick)
  • 5.13 Set logging levels - PASS (tick)
  • 5.14 Set ONOS configurations - PASS (tick)
  • 5.15 Starting Mininet Topology - PASS (tick)
  • 5.16 Check whether the flow count is bigger than 28 - PASS (tick)
  • 5.17 Check whether all flow status are ADDED - PASS (tick)
  • 5.18 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS (tick)
  • 5.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE5 - PASS (tick)
  • 5.20 Stopping Mininet - PASS (tick)
  • 5.21 Copying karaf logs - PASS (tick)

Case 6: Bridging test between two untagged hosts on vlan-untagged port, with dual-homed ToR, ovs switches and 3 ONOS instances -

...

FAIL

  • 6.1 Apply cell to environment - PASS (tick)
  • 6.2 Uninstalling Atomix - PASS (tick)
  • 6.3 Uninstalling ONOS package - PASS (tick)
  • 6.4 Installing Atomix - PASS (tick)
  • 6.5 Installing ONOS package - PASS (tick)
  • 6.6 Set up ONOS secure SSH - PASS (tick)
  • 6.7 Checking ONOS service - PASS (tick)
  • 6.8 Starting ONOS CLI sessions - PASS (tick)
  • 6.9 Checking ONOS nodes - PASS (tick)
  • 6.10 Checking ONOS applications - PASS (tick)
  • 6.11 Set logging levels - PASS (tick)
  • 6.12 Set ONOS configurations - PASS (tick)
  • 6.13 Starting Mininet Topology - PASS (tick)
  • 6.14 Check whether the flow count is bigger than 74 - PASS (tick)FAIL (error)
    • Flow count looks wrong; found 37, expecting at least 74
  • 6.15 Check whether all flow status are ADDED - PASS (tick)
  • 6.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 6.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 6.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE6 - PASS (tick)
  • 6.19 Stopping Mininet - PASS (tick)
  • 6.20 Copying karaf logs - PASS (tick)

...

  • 17.1 Apply cell to environment - PASS (tick)
  • 17.2 Uninstalling Atomix - PASS (tick)
  • 17.3 Uninstalling ONOS package - PASS (tick)
  • 17.4 Installing Atomix - PASS (tick)
  • 17.5 Installing ONOS package - PASS (tick)
  • 17.6 Set up ONOS secure SSH - PASS (tick)
  • 17.7 Checking ONOS service - PASS (tick)
  • 17.8 Starting ONOS CLI sessions - PASS (tick)
  • 17.9 Checking ONOS nodes - PASS (tick)
  • 17.10 Checking ONOS applications - PASS (tick)
  • 17.11 Set logging levels - PASS (tick)
  • 17.12 Set ONOS configurations - PASS (tick)
  • 17.13 Starting Mininet Topology - PASS (tick)
  • 17.14 Check whether the flow count is bigger than 74 - PASS (tick)
  • 17.15 Check whether all flow status are ADDED - PASS (tick)
  • 17.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 17.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 17.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE17 - PASS (tick)
  • 17.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE17 - PASS (tick)
  • 17.20 Stopping Mininet - PASS (tick)
  • 17.21 Copying karaf logs - PASS (tick)

Case 18: Bridging test between two tagged hosts, with 2x4 dual-homed leaf-spine topology, ovs switches and 3 ONOS instances -

...

FAIL

  • 18.1 Apply cell to environment - PASS (tick)
  • 18.2 Uninstalling Atomix - PASS (tick)
  • 18.3 Uninstalling ONOS package - PASS (tick)
  • 18.4 Installing Atomix - PASS (tick)
  • 18.5 Installing ONOS package - PASS (tick)
  • 18.6 Set up ONOS secure SSH - PASS (tick)
  • 18.7 Checking ONOS service - PASS (tick)
  • 18.8 Starting ONOS CLI sessions - PASS (tick)
  • 18.9 Checking ONOS nodes - PASS (tick)
  • 18.10 Checking ONOS applications - PASS (tick)
  • 18.11 Set logging levels - PASS (tick)
  • 18.12 Set ONOS configurations - PASS (tick)
  • 18.13 Starting Mininet Topology - PASS (tick)
  • 18.14 Check whether the flow count is bigger than 212 - PASS (tick)
  • 18.15 Check whether all flow status are ADDED - PASS (tick)
  • 18.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 18.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 18.18 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 18
  • 18.19 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)
  • 18.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE18 - PASS (tick)
  • 18.21 Verify full connectivity for [u'h3', u'h4'] with tag CASE18 - PASS (tick)
  • 18.22 Stopping Mininet - PASS (tick)
  • 18.23 Copying karaf logs - PASS (tick)

...

  • 25.1 Apply cell to environment - PASS (tick)
  • 25.2 Uninstalling Atomix - PASS (tick)
  • 25.3 Uninstalling ONOS package - PASS (tick)
  • 25.4 Installing Atomix - PASS (tick)
  • 25.5 Installing ONOS package - PASS (tick)
  • 25.6 Set up ONOS secure SSH - PASS (tick)
  • 25.7 Checking ONOS service - PASS (tick)
  • 25.8 Starting ONOS CLI sessions - PASS (tick)
  • 25.9 Checking ONOS nodes - PASS (tick)
  • 25.10 Checking ONOS applications - PASS (tick)
  • 25.11 Set logging levels - PASS (tick)
  • 25.12 Set ONOS configurations - PASS (tick)
  • 25.13 Starting Mininet Topology - PASS (tick)
  • 25.14 Check whether the flow count is bigger than 28 - PASS (tick)
  • 25.15 Check whether all flow status are ADDED - PASS (tick)
  • 25.16 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS (tick)
  • 25.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE25 - PASS (tick)
  • 25.18 Stopping Mininet - PASS (tick)
  • 25.19 Copying karaf logs - PASS (tick)

Case 26: Bridging test between two untagged hosts on vlan-native port, with dual-homed ToR, ovs switches and 3 ONOS instances -

...

PASS

  • 26.1 Apply cell to environment - PASS (tick)
  • 26.2 Uninstalling Atomix - PASS (tick)
  • 26.3 Uninstalling ONOS package - PASS (tick)
  • 26.4 Installing Atomix - PASS (tick)
  • 26.5 Installing ONOS package - PASS (tick)
  • 26.6 Set up ONOS secure SSH - PASS (tick)
  • 26.7 Checking ONOS service - PASS (tick)
  • 26.8 Starting ONOS CLI sessions - PASS (tick)
  • 26.9 Checking ONOS nodes - PASS (tick)
  • 26.10 Checking ONOS applications - PASS (tick)
  • 26.11 Set logging levels - PASS (tick)
  • 26.12 Set ONOS configurations - PASS (tick)
  • 26.13 Starting Mininet Topology - PASS (tick)
  • 26.14 Check whether the flow count is bigger than 74 - FAIL (error)
  • Flow count looks wrong; found 39, expecting at least 74
  • count is bigger than 74 - PASS (tick)
  • 26.15 Check whether all flow status are ADDED - PASS (tick)
  • 26.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 26.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 26.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE26 - PASS (tick)
  • 26.19 Stopping Mininet - PASS (tick)
  • 26.20 Copying karaf logs - PASS (tick)

...

  • 35.1 Apply cell to environment - PASS (tick)
  • 35.2 Uninstalling Atomix - PASS (tick)
  • 35.3 Uninstalling ONOS package - PASS (tick)
  • 35.4 Installing Atomix - PASS (tick)
  • 35.5 Installing ONOS package - PASS (tick)
  • 35.6 Set up ONOS secure SSH - PASS (tick)
  • 35.7 Checking ONOS service - PASS (tick)
  • 35.8 Starting ONOS CLI sessions - PASS (tick)
  • 35.9 Checking ONOS nodes - PASS (tick)
  • 35.10 Checking ONOS applications - PASS (tick)
  • 35.11 Set logging levels - PASS (tick)
  • 35.12 Set ONOS configurations - PASS (tick)
  • 35.13 Starting Mininet Topology - PASS (tick)
  • 35.14 Check whether the flow count is bigger than 28 - PASS (tick)
  • 35.15 Check whether all flow status are ADDED - PASS (tick)
  • 35.16 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS (tick)
  • 35.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE35 - PASS (tick)
  • 35.18 Stopping Mininet - PASS (tick)
  • 35.19 Copying karaf logs - PASS (tick)

Case 36: Bridging test between two untagged hosts, one on vlan-untagged port and the other on vlan-native port, with dual-homed ToR, ovs switches and 3 ONOS instances -

...

FAIL

  • 36.1 Apply cell to environment - PASS (tick)
  • 36.2 Uninstalling Atomix - PASS (tick)
  • 36.3 Uninstalling ONOS package - PASS (tick)
  • 36.4 Installing Atomix - PASS (tick)
  • 36.5 Installing ONOS package - PASS (tick)
  • 36.6 Set up ONOS secure SSH - PASS (tick)
  • 36.7 Checking ONOS service - PASS (tick)
  • 36.8 Starting ONOS CLI sessions - PASS (tick)
  • 36.9 Checking ONOS nodes - PASS (tick)
  • 36.10 Checking ONOS applications - PASS (tick)
  • 36.11 Set logging levels - PASS (tick)
  • 36.12 Set ONOS configurations - PASS (tick)
  • 36.13 Starting Mininet Topology - PASS (tick)
  • 36.14 Check whether the flow count is bigger than 74 - PASS (tick)FAIL (error)
    • Flow count looks wrong; found 34, expecting at least 74
  • 36.15 Check whether all flow status are ADDED - PASS (tick)
  • 36.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 36.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 36.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE36 - PASS (tick)
  • 36.19 Stopping Mininet - PASS (tick)
  • 36.20 Copying karaf logs - PASS (tick)

...

  • 37.1 Apply cell to environment - PASS (tick)
  • 37.2 Uninstalling Atomix - PASS (tick)
  • 37.3 Uninstalling ONOS package - PASS (tick)
  • 37.4 Installing Atomix - PASS (tick)
  • 37.5 Installing ONOS package - PASS (tick)
  • 37.6 Set up ONOS secure SSH - PASS (tick)
  • 37.7 Checking ONOS service - PASS (tick)
  • 37.8 Starting ONOS CLI sessions - PASS (tick)
  • 37.9 Checking ONOS nodes - PASS (tick)
  • 37.10 Checking ONOS applications - PASS (tick)
  • 37.11 Set logging levels - PASS (tick)
  • 37.12 Set ONOS configurations - PASS (tick)
  • 37.13 Starting Mininet Topology - PASS (tick)
  • 37.14 Check whether the flow count is bigger than 74 - PASS (tick)
  • 37.15 Check whether all flow status are ADDED - PASS (tick)
  • 37.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 37.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 37.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE37 - PASS (tick)
  • 37.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE37 - PASS (tick)
  • 37.20 Stopping Mininet - PASS (tick)
  • 37.21 Copying karaf logs - PASS (tick)

Case 38: Bridging test between two untagged hosts, one on vlan-untagged port and the other on vlan-native port, with 2x4 dual-homed leaf-spine topology, ovs switches and 3 ONOS instances -

...

FAIL

  • 38.1 Apply cell to environment - PASS (tick)
  • 38.2 Uninstalling Atomix - PASS (tick)
  • 38.3 Uninstalling ONOS package - PASS (tick)
  • 38.4 Installing Atomix - PASS (tick)
  • 38.5 Installing ONOS package - PASS (tick)
  • 38.6 Set up ONOS secure SSH - PASS (tick)
  • 38.7 Checking ONOS service - PASS (tick)
  • 38.8 Starting ONOS CLI sessions - PASS (tick)
  • 38.9 Checking ONOS nodes - PASS (tick)
  • 38.10 Checking ONOS applications - PASS (tick)
  • 38.11 Set logging levels - PASS (tick)
  • 38.12 Set ONOS configurations - PASS (tick)
  • 38.13 Starting Mininet Topology - PASS (tick)
  • 38.14 Check whether the flow count is bigger than 212 - PASS (tick)FAIL (error)
    • Flow count looks wrong; found 104, expecting at least 212
  • 38.15 Check whether all flow status are ADDED - PASS (tick)
  • 38.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 38.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 38.18 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 38.19 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)
  • 38.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE38 - PASS (tick)
  • 38.21 Verify full connectivity for [u'h3', u'h4'] with tag CASE38 - PASS (tick)
  • 38.22 Stopping Mininet - PASS (tick)
  • 38.23 Copying karaf logs - PASS (tick)

...

  • 45.1 Apply cell to environment - PASS (tick)
  • 45.2 Uninstalling Atomix - PASS (tick)
  • 45.3 Uninstalling ONOS package - PASS (tick)
  • 45.4 Installing Atomix - PASS (tick)
  • 45.5 Installing ONOS package - PASS (tick)
  • 45.6 Set up ONOS secure SSH - PASS (tick)
  • 45.7 Checking ONOS service - PASS (tick)
  • 45.8 Starting ONOS CLI sessions - PASS (tick)
  • 45.9 Checking ONOS nodes - PASS (tick)
  • 45.10 Checking ONOS applications - PASS (tick)
  • 45.11 Set logging levels - PASS (tick)
  • 45.12 Set ONOS configurations - PASS (tick)
  • 45.13 Starting Mininet Topology - PASS (tick)
  • 45.14 Check whether the flow count is bigger than 28 - PASS (tick)
  • 45.15 Check whether all flow status are ADDED - PASS (tick)
  • 45.16 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS (tick)
  • 45.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE45 - PASS (tick)
  • 45.18 Stopping Mininet - PASS (tick)
  • 45.19 Copying karaf logs - PASS (tick)

Case 46: Bridging test between untagged host and tagged host, with dual-homed ToR, ovs switches and 3 ONOS instances -

...

FAIL

  • 46.1 Apply cell to environment - PASS (tick)
  • 46.2 Uninstalling Atomix - PASS (tick)
  • 46.3 Uninstalling ONOS package - PASS (tick)
  • 46.4 Installing Atomix - PASS (tick)
  • 46.5 Installing ONOS package - PASS (tick)
  • 46.6 Set up ONOS secure SSH - PASS (tick)
  • 46.7 Checking ONOS service - PASS (tick)
  • 46.8 Starting ONOS CLI sessions - PASS (tick)
  • 46.9 Checking ONOS nodes - PASS (tick)
  • 46.10 Checking ONOS applications - PASS (tick)
  • 46.11 Set logging levels - PASS (tick)
  • 46.12 Set ONOS configurations - PASS (tick)
  • 46.13 Starting Mininet Topology - PASS (tick)
  • 46.14 Check whether the flow count is bigger than 74 - PASS (tick)FAIL (error)
    • Flow count looks wrong; found 34, expecting at least 74
  • 46.15 Check whether all flow status are ADDED - PASS (tick)
  • 46.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 46.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 46.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE46 - PASS (tick)
  • 46.19 Stopping Mininet - PASS (tick)
  • 46.20 Copying karaf logs - PASS (tick)

Case 47: Bridging test between untagged host and tagged host, with 2x2 leaf-spine topology, ovs switches and 3 ONOS instances -

...

FAIL

  • 47.1 Apply cell to environment - PASS (tick)
  • 47.2 Uninstalling Atomix - PASS (tick)
  • 47.3 Uninstalling ONOS package - PASS (tick)
  • 47.4 Installing Atomix - PASS (tick)
  • 47.5 Installing ONOS package - PASS (tick)
  • 47.6 Set up ONOS secure SSH - PASS (tick)
  • 47.7 Checking ONOS service - PASS (tick)
  • 47.8 Starting ONOS CLI sessions - PASS (tick)
  • 47.9 Checking ONOS nodes - PASS (tick)
  • 47.10 Checking ONOS applications - PASS (tick)
  • 47.11 Set logging levels - PASS (tick)
  • 47.12 Set ONOS configurations - PASS (tick)
  • 47.13 Starting Mininet Topology - PASS (tick)
  • 47.14 Check whether the flow count is bigger than 74 - PASS (tick)
  • 47.15 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 47.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 47.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 47.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE47 - PASS (tick)
  • 47.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE47 - PASS (tick)
  • 47.20 Stopping Mininet - PASS (tick)
  • 47.21 Copying karaf logs - PASS (tick)

...

  • 67.1 Apply cell to environment - PASS (tick)
  • 67.2 Uninstalling Atomix - PASS (tick)
  • 67.3 Uninstalling ONOS package - PASS (tick)
  • 67.4 Installing Atomix - PASS (tick)
  • 67.5 Installing ONOS package - PASS (tick)
  • 67.6 Set up ONOS secure SSH - PASS (tick)
  • 67.7 Checking ONOS service - PASS (tick)
  • 67.8 Starting ONOS CLI sessions - PASS (tick)
  • 67.9 Checking ONOS nodes - PASS (tick)
  • 67.10 Checking ONOS applications - PASS (tick)
  • 67.11 Set logging levels - PASS (tick)
  • 67.12 Set ONOS configurations - PASS (tick)
  • 67.13 Starting Mininet Topology - PASS (tick)
  • 67.14 Check whether the flow count is bigger than 74 - PASS (tick)
  • 67.15 Check whether all flow status are ADDED - PASS (tick)
  • 67.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 67.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 67.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE67 - PASS (tick)
  • 67.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE67 - PASS (tick)
  • 67.20 Stopping Mininet - PASS (tick)
  • 67.21 Copying karaf logs - PASS (tick)

Case 68: Bridging test between two tagged hosts with different vlan id, with 2x4 dual-homed leaf-spine topology, ovs switches and 3 ONOS instances -

...

PASS

  • 68.1 Apply cell to environment - PASS (tick)
  • 68.2 Uninstalling Atomix - PASS (tick)
  • 68.3 Uninstalling ONOS package - PASS (tick)
  • 68.4 Installing Atomix - PASS (tick)
  • 68.5 Installing ONOS package - PASS (tick)
  • 68.6 Set up ONOS secure SSH - PASS (tick)
  • 68.7 Checking ONOS service - PASS (tick)
  • 68.8 Starting ONOS CLI sessions - PASS (tick)
  • 68.9 Checking ONOS nodes - PASS (tick)
  • 68.10 Checking ONOS applications - PASS (tick)
  • 68.11 Set logging levels - PASS (tick)
  • 68.12 Set ONOS configurations - PASS (tick)
  • 68.13 Starting Mininet Topology - PASS (tick)
  • 68.14 Check whether the flow count is bigger than 212 - PASS (tick)
  • 68.15 Check whether all flow status are ADDED - PASS (tick)
  • 68.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 68.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - FAIL (error)
  • Flow count looks wrong: 23
  • PASS (tick)
  • 68.18 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 68.19 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)
  • 68.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE68 - PASS (tick)
  • 68.21 Verify full connectivity for [u'h3', u'h4'] with tag CASE68 - PASS (tick)
  • 68.22 Stopping Mininet - PASS (tick)
  • 68.23 Copying karaf logs - PASS (tick)

...