Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric2/lastSuccessfulBuild/artifact/SRDynamicConf_onos-2.5_20-builds_graph.jpg", alt="SRDynamicConf", style="width:525px;height:350px;border:0">

commit 2ca1c3ccf990220acd3985a9ccfd7d8fa860b8f6 f7489d7de016ee9953dbe9ac5a7b9da82829111c (HEAD -] onos-2.5, origin/onos-2.5)
Author: Daniele Moro [daniele@opennetworking.orgONOS Jenkins User [jenkins@onlab.us]
AuthorDate: Thu Jul 8 12:53:26 2021 +0200
Commit: Pier Luigi Ventre [pier@opennetworking.orgMon Sep 20 07:54:42 2021 +0000
Commit: ONOS Jenkins User [jenkins@onlab.us]
CommitDate: Mon Jul 12 17:29:49 Sep 20 07:54:42 2021 +0000
Fix bug when parsing gtp traffic and inner headers
--
(cherry picked from commit ae26f0aaf30b4d5cb4729f69b6810d11de7653ac)

Starting snapshot 2.5.4-SNAPSHOT

Case 13: Changing port configuration from untagged 10 to tagged 10, with 2x2 leaf-spine topology and 3 ONOS instances - PASS

...

  • 33.1 Apply cell to environment - PASS (tick)
  • 33.2 Uninstalling Atomix - PASS (tick)
  • 33.3 Uninstalling ONOS package - PASS (tick)
  • 33.4 Installing Atomix - PASS (tick)
  • 33.5 Installing ONOS package - PASS (tick)
  • 33.6 Set up ONOS secure SSH - PASS (tick)
  • 33.7 Checking ONOS service - PASS (tick)
  • 33.8 Starting ONOS CLI sessions - PASS (tick)
  • 33.9 Checking ONOS nodes - PASS (tick)
  • 33.10 Checking ONOS applications - PASS (tick)
  • 33.11 Set logging levels - PASS (tick)
  • 33.12 Set ONOS configurations - PASS (tick)
  • 33.13 Starting Mininet Topology - PASS (tick)
  • 33.14 Check whether the flow count is bigger than 104 - PASS (tick)
  • 33.15 Check whether all flow status are ADDED - PASS (tick)
  • 33.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE33_Before - PASS (tick)
  • 33.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE33_Before - PASS (tick)
  • 33.18 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 33.19 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 33.20 Check whether the flow count is bigger than 104 - PASS (tick)
  • 33.21 Check whether all flow status are ADDED - PASS (tick)
  • 33.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE33_After - PASS (tick)
  • 33.23 Verify full connectivity for [u'h1', u'h2'] with tag CASE33_After - PASS (tick)
  • 33.24 Stopping Mininet - PASS (tick)
  • 33.25 Copying karaf logs - PASS (tick)

Case 43: Changing port configuration from untagged 10 to tagged 20, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 43.1 Apply cell to environment - PASS (tick)
  • 43.2 Uninstalling Atomix - PASS (tick)
  • 43.3 Uninstalling ONOS package - PASS (tick)
  • 43.4 Installing Atomix - PASS (tick)
  • 43.5 Installing ONOS package - PASS (tick)
  • 43.6 Set up ONOS secure SSH - PASS (tick)
  • 43.7 Checking ONOS service - PASS (tick)
  • 43.8 Starting ONOS CLI sessions - PASS (tick)
  • 43.9 Checking ONOS nodes - PASS (tick)
  • 43.10 Checking ONOS applications - PASS (tick)
  • 43.11 Set logging levels - PASS (tick)
  • 43.12 Set ONOS configurations - PASS (tick)
  • 43.13 Starting Mininet Topology - PASS (tick)
  • 43.14 Check whether the flow count is bigger than 104 - PASS (tick)
  • 43.15 Check whether all flow status are ADDED - PASS (tick)
  • 43.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE43_Before - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 43.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE43_Before - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 43.18 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 43.19 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 43.20 Check whether the flow count is bigger than 104 - PASS (tick)
  • 43.21 Check whether all flow status are ADDED - PASS (tick)
  • 43.22 Verify full connectivity for [u'h1', u'h2'] with tag CASE43_After - PASS (tick)
  • 43.23 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE43_After - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 43.24 Stopping Mininet - PASS (tick)
  • 43.25 Copying karaf logs - PASS (tick)

...

  • 73.1 Apply cell to environment - PASS (tick)
  • 73.2 Uninstalling Atomix - PASS (tick)
  • 73.3 Uninstalling ONOS package - PASS (tick)
  • 73.4 Installing Atomix - PASS (tick)
  • 73.5 Installing ONOS package - PASS (tick)
  • 73.6 Set up ONOS secure SSH - PASS (tick)
  • 73.7 Checking ONOS service - PASS (tick)
  • 73.8 Starting ONOS CLI sessions - PASS (tick)
  • 73.9 Checking ONOS nodes - PASS (tick)
  • 73.10 Checking ONOS applications - PASS (tick)
  • 73.11 Set logging levels - PASS (tick)
  • 73.12 Set ONOS configurations - PASS (tick)
  • 73.13 Starting Mininet Topology - PASS (tick)
  • 73.14 Check whether the flow count is bigger than 106 - PASS (tick)
  • 73.15 Check whether all flow status are ADDED - PASS (tick)
  • 73.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE73_Before - PASS (tick)
  • 73.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE73_Before - PASS (tick)
  • 73.18 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 73.19 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 73.20 Check whether the flow count is bigger than 106 - PASS (tick)
  • 73.21 Check whether all flow status are ADDED - PASS (tick)
  • 73.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE73_After - PASS (tick)
  • 73.23 Verify full connectivity for [u'h1', u'h2'] with tag CASE73_After - PASS (tick)
  • 73.24 Stopping Mininet - PASS (tick)
  • 73.25 Copying karaf logs - PASS (tick)

Case 83: Changing port configuration from tagged 20 to tagged 20 and native 10, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 83.1 Apply cell to environment - PASS (tick)
  • 83.2 Uninstalling Atomix - PASS (tick)
  • 83.3 Uninstalling ONOS package - PASS (tick)
  • 83.4 Installing Atomix - PASS (tick)
  • 83.5 Installing ONOS package - PASS (tick)
  • 83.6 Set up ONOS secure SSH - PASS (tick)
  • 83.7 Checking ONOS service - PASS (tick)
  • 83.8 Starting ONOS CLI sessions - PASS (tick)
  • 83.9 Checking ONOS nodes - PASS (tick)
  • 83.10 Checking ONOS applications - PASS (tick)
  • 83.11 Set logging levels - PASS (tick)
  • 83.12 Set ONOS configurations - PASS (tick)
  • 83.13 Starting Mininet Topology - PASS (tick)
  • 83.14 Check whether the flow count is bigger than 104 - PASS (tick)
  • 83.15 Check whether all flow status are ADDED - PASS (tick)
  • 83.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE83_Before - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 83.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE83_Before - PASS (tick)
  • 83.18 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 83.19 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 83.20 Check whether the flow count is bigger than 104 - PASS (tick)
  • 83.21 Check whether all flow status are ADDED - PASS (tick)
  • 83.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE83_After - PASS (tick)
  • 83.23 Verify full connectivity for [u'h1', u'h2'] with tag CASE83_After - PASS (tick)
  • 83.24 Stopping Mininet - PASS (tick)
  • 83.25 Copying karaf logs - PASS (tick)

...

  • 193.1 Apply cell to environment - PASS (tick)
  • 193.2 Uninstalling Atomix - PASS (tick)
  • 193.3 Uninstalling ONOS package - PASS (tick)
  • 193.4 Installing Atomix - PASS (tick)
  • 193.5 Installing ONOS package - PASS (tick)
  • 193.6 Set up ONOS secure SSH - PASS (tick)
  • 193.7 Checking ONOS service - PASS (tick)
  • 193.8 Starting ONOS CLI sessions - PASS (tick)
  • 193.9 Checking ONOS nodes - PASS (tick)
  • 193.10 Checking ONOS applications - PASS (tick)
  • 193.11 Set logging levels - PASS (tick)
  • 193.12 Set ONOS configurations - PASS (tick)
  • 193.13 Starting Mininet Topology - PASS (tick)
  • 193.14 Check whether the flow count is bigger than 106 - PASS (tick)
  • 193.15 Check whether all flow status are ADDED - PASS (tick)
  • 193.16 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE193_Before - PASS (tick)
  • 193.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE193_Before - PASS (tick)
  • 193.18 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 193.19 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 193.20 Check whether the flow count is bigger than 106 - PASS (tick)
  • 193.21 Check whether all flow status are ADDED - PASS (tick)
  • 193.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE193_After - PASS (tick)
  • 193.23 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE193_After - PASS (tick)
  • 193.24 Stopping Mininet - PASS (tick)
  • 193.25 Copying karaf logs - PASS (tick)

Case 203: Changing port configuration from tagged 20 and native 10 to tagged 20, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 203.1 Apply cell to environment - PASS (tick)
  • 203.2 Uninstalling Atomix - PASS (tick)
  • 203.3 Uninstalling ONOS package - PASS (tick)
  • 203.4 Installing Atomix - PASS (tick)
  • 203.5 Installing ONOS package - PASS (tick)
  • 203.6 Set up ONOS secure SSH - PASS (tick)
  • 203.7 Checking ONOS service - PASS (tick)
  • 203.8 Starting ONOS CLI sessions - PASS (tick)
  • 203.9 Checking ONOS nodes - PASS (tick)
  • 203.10 Checking ONOS applications - PASS (tick)
  • 203.11 Set logging levels - PASS (tick)
  • 203.12 Set ONOS configurations - PASS (tick)
  • 203.13 Starting Mininet Topology - PASS (tick)
  • 203.14 Check whether the flow count is bigger than 106 - PASS (tick)
  • 203.15 Check whether all flow status are ADDED - PASS (tick)
  • 203.16 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE203_Before - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 203.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE203_Before - PASS (tick)
  • 203.18 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 203.19 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 203.20 Check whether the flow count is bigger than 106 - PASS (tick)
  • 203.21 Check whether all flow status are ADDED - PASS (tick)
  • 203.22 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE203_After - PASS (tick)
  • 203.23 Verify full connectivity for [u'h1', u'h2'] with tag CASE203_After - PASS (tick)
  • 203.24 Stopping Mininet - PASS (tick)
  • 203.25 Copying karaf logs - PASS (tick)

Case 213: Changing port configuration from tagged 20 and native 10 to tagged 20 and native 110, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 213.1 Apply cell to environment - PASS (tick)
  • 213.2 Uninstalling Atomix - PASS (tick)
  • 213.3 Uninstalling ONOS package - PASS (tick)
  • 213.4 Installing Atomix - PASS (tick)
  • 213.5 Installing ONOS package - PASS (tick)
  • 213.6 Set up ONOS secure SSH - PASS (tick)
  • 213.7 Checking ONOS service - PASS (tick)
  • 213.8 Starting ONOS CLI sessions - PASS (tick)
  • 213.9 Checking ONOS nodes - PASS (tick)
  • 213.10 Checking ONOS applications - PASS (tick)
  • 213.11 Set logging levels - PASS (tick)
  • 213.12 Set ONOS configurations - PASS (tick)
  • 213.13 Starting Mininet Topology - PASS (tick)
  • 213.14 Check whether the flow count is bigger than 106 - PASS (tick)
  • 213.15 Check whether all flow status are ADDED - PASS (tick)
  • 213.16 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE213_Before - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 213.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE213_Before - PASS (tick)
  • 213.18 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 213.19 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 213.20 Check whether the flow count is bigger than 106 - PASS (tick)
  • 213.21 Check whether all flow status are ADDED - PASS (tick)
  • 213.22 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE213_After - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 213.23 Verify full connectivity for [u'h1', u'h2'] with tag CASE213_After - PASS (tick)
  • 213.24 Stopping Mininet - PASS (tick)
  • 213.25 Copying karaf logs - PASS (tick)

Case 223: Changing port configuration from tagged 20 and native 10 to tagged 120 and native 10, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 223.1 Apply cell to environment - PASS (tick)
  • 223.2 Uninstalling Atomix - PASS (tick)
  • 223.3 Uninstalling ONOS package - PASS (tick)
  • 223.4 Installing Atomix - PASS (tick)
  • 223.5 Installing ONOS package - PASS (tick)
  • 223.6 Set up ONOS secure SSH - PASS (tick)
  • 223.7 Checking ONOS service - PASS (tick)
  • 223.8 Starting ONOS CLI sessions - PASS (tick)
  • 223.9 Checking ONOS nodes - PASS (tick)
  • 223.10 Checking ONOS applications - PASS (tick)
  • 223.11 Set logging levels - PASS (tick)
  • 223.12 Set ONOS configurations - PASS (tick)
  • 223.13 Starting Mininet Topology - PASS (tick)
  • 223.14 Check whether the flow count is bigger than 106 - PASS (tick)
  • 223.15 Check whether all flow status are ADDED - PASS (tick)
  • 223.16 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE223_Before - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 223.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE223_Before - PASS (tick)
  • 223.18 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 223.19 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 223.20 Check whether the flow count is bigger than 106 - PASS (tick)
  • 223.21 Check whether all flow status are ADDED - PASS (tick)
  • 223.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE223_After - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 223.23 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE223_After - PASS (tick)
  • 223.24 Stopping Mininet - PASS (tick)
  • 223.25 Copying karaf logs - PASS (tick)

...

  • 233.1 Apply cell to environment - PASS (tick)
  • 233.2 Uninstalling Atomix - PASS (tick)
  • 233.3 Uninstalling ONOS package - PASS (tick)
  • 233.4 Installing Atomix - PASS (tick)
  • 233.5 Installing ONOS package - PASS (tick)
  • 233.6 Set up ONOS secure SSH - PASS (tick)
  • 233.7 Checking ONOS service - PASS (tick)
  • 233.8 Starting ONOS CLI sessions - PASS (tick)
  • 233.9 Checking ONOS nodes - PASS (tick)
  • 233.10 Checking ONOS applications - PASS (tick)
  • 233.11 Set logging levels - PASS (tick)
  • 233.12 Set ONOS configurations - PASS (tick)
  • 233.13 Starting Mininet Topology - PASS (tick)
  • 233.14 Check whether the flow count is bigger than 104 - PASS (tick)
  • 233.15 Check whether all flow status are ADDED - PASS (tick)
  • 233.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_Before - PASS (tick)
  • 233.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_Before - PASS (tick)
  • 233.18 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 233.19 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 233.20 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 233.21 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 233.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_1 - PASS (tick)
  • 233.23 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_1 - PASS (tick)
  • 233.24 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 233.25 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 233.26 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_2 - PASS (tick)
  • 233.27 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_2 - PASS (tick)
  • 233.28 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 233.29 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 233.30 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_3 - PASS (tick)
  • 233.31 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_3 - PASS (tick)
  • 233.32 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 233.33 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 233.34 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_4 - PASS (tick)
  • 233.35 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_4 - FAIL (error)
    • IP connectivity failed
  • 233.36 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 233.37 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 233.38 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_5 - PASS (tick)
  • 233.39 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_5 - PASS (tick)
  • 233.40 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 233.41 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 233.42 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_6 - PASS (tick)
  • 233.43 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_6 - PASS (tick)
  • 233.44 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 233.45 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 233.46 Check whether the flow count is bigger than 104 - PASS (tick)
  • 233.47 Check whether all flow status are ADDED - FAIL (error)
  • Flow status is wrong!
  • PASS (tick)
  • 233.48 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_After - PASS (tick)
  • 233.49 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_After - PASS (tick)
  • 233.50 Stopping Mininet - PASS (tick)
  • 233.51 Copying karaf logs - PASS (tick)

...