Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric2/lastSuccessfulBuild/artifact/SRHighAvailability_onos-2.5_20-builds_graph.jpg", alt="SRHighAvailability", style="width:525px;height:350px;border:0">

commit 78b4d6f3c3060bba748e7b51af615abf796e1e94 589398d34b6d22baffaf2ec1b1319195bb01ee47 (HEAD -] onos-2.5, origin/onos-2.5)
Author: pierventre [pier@opennetworking.orgMatteo Scandolo [matteo.scandolo@gmail.com]
AuthorDate: Fri Aug 27 17:20:00 2021 +0200Thu Sep 16 08:35:43 2021 -0700
Commit: Pier Luigi Ventre [pier@opennetworkingMatteo Scandolo [teo@opennetworking.org]
CommitDate: Thu Fri Sep 2 17 16:2916:24 25 2021 +0000
[SDFAB-522] Fix port type for pair ports

Case 1: High Availability tests - ONOS failures 2x2 Leaf-spine - FAIL

  • 1.1 Constructing test variables - PASS (tick)
  • 1.2 Apply cell to environment - PASS (tick)
  • 1.3 Uninstalling Atomix - PASS (tick)
  • 1.4 Uninstalling ONOS package - PASS (tick)
  • 1.5 Creating ONOS package - PASS (tick)
  • 1.6 Installing Atomix - PASS (tick)
  • 1.7 Installing ONOS package - PASS (tick)
  • 1.8 Set up ONOS secure SSH - PASS (tick)
  • 1.9 Checking ONOS service - PASS (tick)
  • 1.10 Starting ONOS CLI sessions - PASS (tick)
  • 1.11 Checking ONOS nodes - PASS (tick)
  • 1.12 Checking ONOS applications - PASS (tick)
  • 1.13 Set logging levels - PASS (tick)
  • 1.14 Set ONOS configurations - PASS (tick)
  • 1.15 Starting Mininet Topology - PASS (tick)
  • 1.16 Check whether the flow count is bigger than 116 - FAIL (error)
    • Flow count looks wrong; found False, expecting at least 116
  • 1.17 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 1.18 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.19 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.20 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.21 Killing ONOS instances with index(es): [0] - PASS (tick)
  • 1.22 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers
  • 1.23 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_ONOS_Failure1 - FAIL (error)
    • IP connectivity failed
  • 1.24 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_ONOS_Failure1 - FAIL (error)
    • IP connectivity failed
  • 1.25 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_ONOS_Failure1 - FAIL (error)
    • IP connectivity failed
  • 1.26 Recovering ONOS instances with index(es): [0] - PASS (tick)
  • 1.27 Checking if ONOS CLI is ready - PASS (tick)
  • 1.28 Checking ONOS nodes - PASS (tick)
  • 1.29 Check number of topology elements - PASS (tick)
  • 1.30 Check whether the flow count is bigger than 116 - PASS (tick)
  • 1.31 Check whether all flow status are ADDED - PASS (tick)
  • 1.32 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_ONOS_Recovery1 - FAIL (error)
    • IP connectivity failed
  • 1.33 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_ONOS_Recovery1 - FAIL (error)
    • IP connectivity failed
  • 1.34 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_ONOS_Recovery1 - FAIL (error)
    • IP connectivity failed
  • 1.35 Killing ONOS instances with index(es): [1] - PASS (tick)
  • 1.36 Check number of topology elements - PASS (tick)
  • 1.37 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_ONOS_Failure2 - FAIL (error)
    • IP connectivity failed
  • 1.38 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_ONOS_Failure2 - FAIL (error)
    • IP connectivity failed
  • 1.39 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_ONOS_Failure2 - FAIL (error)
    • IP connectivity failed
  • 1.40 Recovering ONOS instances with index(es): [1] - PASS (tick)
  • 1.41 Checking if ONOS CLI is ready - PASS (tick)
  • 1.42 Checking ONOS nodes - PASS (tick)
  • 1.43 Check number of topology elements - PASS (tick)
  • 1.44 Check whether the flow count is bigger than 116 - PASS (tick)
  • 1.45 Check whether all flow status are ADDED - PASS (tick)
  • 1.46 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_ONOS_Recovery2 - FAIL (error)
    • IP connectivity failed
  • 1.47 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_ONOS_Recovery2 - FAIL (error)
    • IP connectivity failed
  • 1.48 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_ONOS_Recovery2 - FAIL (error)
    • IP connectivity failed
  • 1.49 Killing ONOS instances with index(es): [2] - PASS (tick)
  • 1.50 Check number of topology elements - PASS (tick)
  • 1.51 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_ONOS_Failure3 - FAIL (error)
    • IP connectivity failed
  • 1.52 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_ONOS_Failure3 - FAIL (error)
    • IP connectivity failed
  • 1.53 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_ONOS_Failure3 - FAIL (error)
    • IP connectivity failed
  • 1.54 Recovering ONOS instances with index(es): [2] - PASS (tick)
  • 1.55 Checking if ONOS CLI is ready - PASS (tick)
  • 1.56 Checking ONOS nodes - PASS (tick)
  • 1.57 Check number of topology elements - PASS (tick)
  • 1.58 Check whether the flow count is bigger than 116 - PASS (tick)
  • 1.59 Check whether all flow status are ADDED - PASS (tick)
  • 1.60 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_ONOS_Recovery3 - FAIL (error)
    • IP connectivity failed
  • 1.61 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_ONOS_Recovery3 - FAIL (error)
    • IP connectivity failed
  • 1.62 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_ONOS_Recovery3 - FAIL (error)
    • IP connectivity failed
  • 1.63 Stopping Mininet - PASS (tick)
  • 1.64 Copying karaf logs - PASS (tick)

Bumping onos-maven-plugin version in onos-dependencies
--
(cherry picked from commit cabf6f84272b2b104f8d517f9994c7d845d992dd)

Case 1: High Availability tests - ONOS

...

failures 2x2 Leaf-spine - FAIL