Case 183: Changing port configuration from tagged 20 to tagged 20 and native 10, with 2x2 leaf-spine topology and 3 ONOS instances - FAIL

  • 183.1 Apply cell to environment - PASS (tick)
  • 183.2 Uninstalling Atomix - PASS (tick)
  • 183.3 Uninstalling ONOS package - PASS (tick)
  • 183.4 Create Cluster Config - PASS (tick)
  • 183.5 Installing Atomix via docker containers - PASS (tick)
  • 183.6 Installing ONOS via docker containers - PASS (tick)
  • 183.7 Set up ONOS secure SSH - PASS (tick)
  • 183.8 Starting ONOS CLI sessions - PASS (tick)
  • 183.9 Checking ONOS nodes - PASS (tick)
  • 183.10 Checking ONOS applications - PASS (tick)
  • 183.11 Set logging levels - PASS (tick)
  • 183.12 Set ONOS configurations - PASS (tick)
  • 183.13 Starting Mininet Topology - PASS (tick)
  • 183.14 Configure switches in ONOS - PASS (tick)
  • 183.15 Check whether the flow count is >= 106 - PASS (tick)
  • 183.16 Check whether all flow status are ADDED - PASS (tick)
  • 183.17 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE183_Before - PASS (tick)
  • 183.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE183_Before - PASS (tick)
  • 183.19 Check whether the flow count of device device:bmv2:leaf1 >= than 53 - PASS (tick)
  • 183.20 Check whether the flow count of device device:bmv2:leaf2 >= than 53 - PASS (tick)
  • 183.21 Check whether the flow count is >= 106 - PASS (tick)
  • 183.22 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 183.23 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE183_After - PASS (tick)
  • 183.24 Verify full connectivity for [u'h1', u'h2'] with tag CASE183_After - PASS (tick)
  • 183.25 Stopping Mininet - PASS (tick)
  • 183.26 Copying karaf logs - PASS (tick)

Case 193: Changing port configuration from tagged 20 and native 10 to untagged 20, with 2x2 leaf-spine topology and 3 ONOS instances - FAIL

  • 193.1 Apply cell to environment - PASS (tick)
  • 193.2 Uninstalling Atomix - PASS (tick)
  • 193.3 Uninstalling ONOS package - PASS (tick)
  • 193.4 Create Cluster Config - PASS (tick)
  • 193.5 Installing Atomix via docker containers - PASS (tick)
  • 193.6 Installing ONOS via docker containers - PASS (tick)
  • 193.7 Set up ONOS secure SSH - PASS (tick)
  • 193.8 Starting ONOS CLI sessions - PASS (tick)
  • 193.9 Checking ONOS nodes - PASS (tick)
  • 193.10 Checking ONOS applications - PASS (tick)
  • 193.11 Set logging levels - PASS (tick)
  • 193.12 Set ONOS configurations - PASS (tick)
  • 193.13 Starting Mininet Topology - PASS (tick)
  • 193.14 Configure switches in ONOS - PASS (tick)
  • 193.15 Check whether the flow count is >= 106 - PASS (tick)
  • 193.16 Check whether all flow status are ADDED - PASS (tick)
  • 193.17 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE193_Before - PASS (tick)
  • 193.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE193_Before - PASS (tick)
  • 193.19 Check whether the flow count of device device:bmv2:leaf1 >= than 53 - PASS (tick)
  • 193.20 Check whether the flow count of device device:bmv2:leaf2 >= than 53 - PASS (tick)
  • 193.21 Check whether the flow count is >= 106 - PASS (tick)
  • 193.22 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 193.23 Verify full connectivity for [u'h3', u'h4'] with tag CASE193_After - PASS (tick)
  • 193.24 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE193_After - PASS (tick)
  • 193.25 Stopping Mininet - PASS (tick)
  • 193.26 Copying karaf logs - PASS (tick)

Case 203: Changing port configuration from tagged 20 and native 10 to tagged 20, with 2x2 leaf-spine topology and 3 ONOS instances - PASS

  • 203.1 Apply cell to environment - PASS (tick)
  • 203.2 Uninstalling Atomix - PASS (tick)
  • 203.3 Uninstalling ONOS package - PASS (tick)
  • 203.4 Create Cluster Config - PASS (tick)
  • 203.5 Installing Atomix via docker containers - PASS (tick)
  • 203.6 Installing ONOS via docker containers - PASS (tick)
  • 203.7 Set up ONOS secure SSH - PASS (tick)
  • 203.8 Starting ONOS CLI sessions - PASS (tick)
  • 203.9 Checking ONOS nodes - PASS (tick)
  • 203.10 Checking ONOS applications - PASS (tick)
  • 203.11 Set logging levels - PASS (tick)
  • 203.12 Set ONOS configurations - PASS (tick)
  • 203.13 Starting Mininet Topology - PASS (tick)
  • 203.14 Configure switches in ONOS - PASS (tick)
  • 203.15 Check whether the flow count is >= 106 - PASS (tick)
  • 203.16 Check whether all flow status are ADDED - PASS (tick)
  • 203.17 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE203_Before - PASS (tick)
  • 203.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE203_Before - PASS (tick)
  • 203.19 Check whether the flow count of device device:bmv2:leaf1 >= than 53 - PASS (tick)
  • 203.20 Check whether the flow count of device device:bmv2:leaf2 >= than 53 - PASS (tick)
  • 203.21 Check whether the flow count is >= 106 - PASS (tick)
  • 203.22 Check whether all flow status are ADDED - PASS (tick)
  • 203.23 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE203_After - PASS (tick)
  • 203.24 Verify full connectivity for [u'h1', u'h2'] with tag CASE203_After - PASS (tick)
  • 203.25 Stopping Mininet - PASS (tick)
  • 203.26 Copying karaf logs - PASS (tick)

Case 213: Changing port configuration from tagged 20 and native 10 to tagged 20 and native 110, with 2x2 leaf-spine topology and 3 ONOS instances - FAIL

  • 213.1 Apply cell to environment - PASS (tick)
  • 213.2 Uninstalling Atomix - PASS (tick)
  • 213.3 Uninstalling ONOS package - PASS (tick)
  • 213.4 Create Cluster Config - PASS (tick)
  • 213.5 Installing Atomix via docker containers - PASS (tick)
  • 213.6 Installing ONOS via docker containers - PASS (tick)
  • 213.7 Set up ONOS secure SSH - PASS (tick)
  • 213.8 Starting ONOS CLI sessions - PASS (tick)
  • 213.9 Checking ONOS nodes - PASS (tick)
  • 213.10 Checking ONOS applications - PASS (tick)
  • 213.11 Set logging levels - PASS (tick)
  • 213.12 Set ONOS configurations - PASS (tick)
  • 213.13 Starting Mininet Topology - PASS (tick)
  • 213.14 Configure switches in ONOS - PASS (tick)
  • 213.15 Check whether the flow count is >= 106 - PASS (tick)
  • 213.16 Check whether all flow status are ADDED - PASS (tick)
  • 213.17 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE213_Before - PASS (tick)
  • 213.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE213_Before - PASS (tick)
  • 213.19 Check whether the flow count of device device:bmv2:leaf1 >= than 53 - PASS (tick)
  • 213.20 Check whether the flow count of device device:bmv2:leaf2 >= than 53 - PASS (tick)
  • 213.21 Check whether the flow count is >= 106 - PASS (tick)
  • 213.22 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 213.23 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE213_After - PASS (tick)
  • 213.24 Verify full connectivity for [u'h1', u'h2'] with tag CASE213_After - PASS (tick)
  • 213.25 Stopping Mininet - PASS (tick)
  • 213.26 Copying karaf logs - PASS (tick)

Case 223: Changing port configuration from tagged 20 and native 10 to tagged 120 and native 10, with 2x2 leaf-spine topology and 3 ONOS instances - FAIL

  • 223.1 Apply cell to environment - PASS (tick)
  • 223.2 Uninstalling Atomix - PASS (tick)
  • 223.3 Uninstalling ONOS package - PASS (tick)
  • 223.4 Create Cluster Config - PASS (tick)
  • 223.5 Installing Atomix via docker containers - PASS (tick)
  • 223.6 Installing ONOS via docker containers - PASS (tick)
  • 223.7 Set up ONOS secure SSH - PASS (tick)
  • 223.8 Starting ONOS CLI sessions - PASS (tick)
  • 223.9 Checking ONOS nodes - PASS (tick)
  • 223.10 Checking ONOS applications - PASS (tick)
  • 223.11 Set logging levels - PASS (tick)
  • 223.12 Set ONOS configurations - PASS (tick)
  • 223.13 Starting Mininet Topology - PASS (tick)
  • 223.14 Configure switches in ONOS - PASS (tick)
  • 223.15 Check whether the flow count is >= 106 - PASS (tick)
  • 223.16 Check whether all flow status are ADDED - PASS (tick)
  • 223.17 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE223_Before - PASS (tick)
  • 223.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE223_Before - PASS (tick)
  • 223.19 Check whether the flow count of device device:bmv2:leaf1 >= than 53 - PASS (tick)
  • 223.20 Check whether the flow count of device device:bmv2:leaf2 >= than 53 - PASS (tick)
  • 223.21 Check whether the flow count is >= 106 - PASS (tick)
  • 223.22 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 223.23 Verify full connectivity for [u'h3', u'h4'] with tag CASE223_After - PASS (tick)
  • 223.24 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE223_After - PASS (tick)
  • 223.25 Stopping Mininet - PASS (tick)
  • 223.26 Copying karaf logs - PASS (tick)

Case 233: Consecutive configuration changes, with 2x2 leaf-spine topology and 3 ONOS instances - FAIL