- 104.1 Apply cell to environment - PASS
- 104.2 Uninstalling Atomix - PASS
- 104.3 Uninstalling ONOS package - PASS
- 104.4 Installing Atomix - PASS
- 104.5 Installing ONOS package - PASS
- 104.6 Set up ONOS secure SSH - PASS
- 104.7 Checking ONOS service - PASS
- 104.8 Starting ONOS CLI sessions - PASS
- 104.9 Checking ONOS nodes - PASS
- 104.10 Checking ONOS applications - PASS
- 104.11 Starting Mininet Topology - PASS
- 104.12 Verify host IP address assignment in ONOS - PASS
- 104.13 Verify IP address assignment from hosts - PASS
- 104.14 Verify reachability of connected internal IPv4 hosts - PASS 104.15 FAIL
- Verify reachability
- of connected internal IPv4 hosts: Fail
- 104.15 Stopping Mininet to external IPv4 hosts - PASS
- 104.16 Killing a batch of links [['spine103', 'spine101'], ['leaf2', 'spine101'], ['leaf3', 'spine101'], ['leaf4', 'spine101'], ['leaf5', 'spine101']] - PASS
- 104.17 Verify host IP address assignment in ONOS - PASS
- 104.18 Verify IP address assignment from hosts - PASS
- 104.19 Verify reachability of connected internal IPv4 hosts - FAIL
- Verify reachability of connected internal IPv4 hosts: Fail
- 104.20 Stopping Mininet - PASS
- Skipping the rest of this case.
Case 105: Test link failures with IPv6 hosts including external hosts - FAIL
- 105.1 Apply cell to environment - PASS
- 105.2 Uninstalling Atomix - PASS
- 105.3 Uninstalling ONOS package - PASS
- 105.4 Installing Atomix - PASS
- 105.5 Installing ONOS package - PASS
- 105.6 Set up ONOS secure SSH - PASS
- 105.7 Checking ONOS service - PASS
- 105.8 Starting ONOS CLI sessions - PASS
- 105.9 Checking ONOS nodes - PASS
- 105.10 Checking ONOS applications - PASS
- 105.11 Starting Mininet Topology - PASS
- 105.12 Verify host IP address assignment in ONOS - PASS
- 105.13 Verify IP address assignment from hosts - PASS
- 105.14 Verify reachability of connected internal IPv6 hosts - FAIL
- Verify reachability of connected internal IPv6 hosts: Fail
- 105.15 Stopping Mininet - PASS
- Skipping the rest of this case.
Case 106: Test link failures with IPv4 and IPv6 hosts including external hosts - FAIL
- 106.1 Apply cell to environment - PASS
- 106.2 Uninstalling Atomix - PASS
- 106.3 Uninstalling ONOS package - PASS
- 106.4 Installing Atomix - PASS
- 106.5 Installing ONOS package - PASS
- 106.6 Set up ONOS secure SSH - PASS
- 106.7 Checking ONOS service - PASS
- 106.8 Starting ONOS CLI sessions - PASS
- 106.9 Checking ONOS nodes - PASS
- 106.10 Checking ONOS applications - PASS
- 106.11 Starting Mininet Topology - PASS
- 106.12 Verify host IP address assignment in ONOS - PASS
- 106.13 Verify IP address assignment from hosts - PASS
- 106.14 Verify reachability of connected internal IPv4 hosts - PASS
- 106.15 Verify reachability of connected internal IPv6 hosts - FAIL
- Verify reachability of connected internal IPv6 hosts: Fail
- 106.16 Stopping Mininet - PASS
- Skipping the rest of this case.
Case 107: Test link failures with IPv4 hosts including external hosts configured with route-add command - PASS
- 107.1 Apply cell to environment - PASS
- 107.2 Uninstalling Atomix - PASS
- 107.3 Uninstalling ONOS package - PASS
- 107.4 Installing Atomix - PASS
- 107.5 Installing ONOS package - PASS
- 107.6 Set up ONOS secure SSH - PASS
- 107.7 Checking ONOS service - PASS
- 107.8 Starting ONOS CLI sessions - PASS
- 107.9 Checking ONOS nodes - PASS
- 107.10 Checking ONOS applications - PASS
- 107.11 Starting Mininet Topology - PASS
- 107.12 Verify host IP address assignment in ONOS - PASS
- 107.13 Verify IP address assignment from hosts - PASS
- 107.14 Verify reachability of connected internal IPv4 hosts - PASS
- 107.15 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 107.16 Killing a batch of links [['spine103', 'spine101'], ['leaf2', 'spine101'], ['leaf3', 'spine101'], ['leaf4', 'spine101'], ['leaf5', 'spine101']] - PASS
- 107.17 Verify host IP address assignment in ONOS - PASS
- 107.18 Verify IP address assignment from hosts - PASS
- 107.19 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 107.20 Restoring a batch of links [['spine103', 'spine101'], ['leaf2', 'spine101'], ['leaf3', 'spine101'], ['leaf4', 'spine101'], ['leaf5', 'spine101']] - PASS
- 107.21 Verify host IP address assignment in ONOS - PASS
- 107.22 Verify IP address assignment from hosts - PASS
- 107.23 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 107.24 Killing a batch of links [['spine104', 'spine102'], ['leaf2', 'spine102'], ['leaf3', 'spine102'], ['leaf4', 'spine102'], ['leaf5', 'spine102']] - PASS
- 107.25 Verify host IP address assignment in ONOS - PASS
- 107.26 Verify IP address assignment from hosts - PASS
- 107.27 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 107.28 Restoring a batch of links [['spine104', 'spine102'], ['leaf2', 'spine102'], ['leaf3', 'spine102'], ['leaf4', 'spine102'], ['leaf5', 'spine102']] - PASS
- 107.29 Verify host IP address assignment in ONOS - PASS
- 107.30 Verify IP address assignment from hosts - PASS
- 107.31 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 107.32 Stopping Mininet - PASS
Case 108: Test link failures with IPv6 hosts including external hosts configured with route-add command - FAIL
- 108.1 Apply cell to environment - PASS
- 108.2 Uninstalling Atomix - PASS
- 108.3 Uninstalling ONOS package - PASS
- 108.4 Installing Atomix - PASS
- 108.5 Installing ONOS package - PASS
- 108.6 Set up ONOS secure SSH - PASS
- 108.7 Checking ONOS service - PASS
- 108.8 Starting ONOS CLI sessions - PASS
- 108.9 Checking ONOS nodes - PASS
- 108.10 Checking ONOS applications - PASS
- 108.11 Starting Mininet Topology - PASS
- 108.12 Verify host IP address assignment in ONOS - PASS
- 108.13 Verify IP address assignment from hosts - PASS
- 108.14 Verify reachability of connected internal IPv6 hosts - FAIL
- Verify reachability of connected internal IPv6 hosts: Fail
- 108.15 Stopping Mininet - PASS
- Skipping the rest of this case.
Case 109: Test link failures with IPv4 and IPv6 hosts including external hosts configured with route-add command - FAIL
- 109.1 Apply cell to environment - PASS
- 109.2 Uninstalling Atomix - PASS
- 109.3 Uninstalling ONOS package - PASS
- 109.4 Installing Atomix - PASS
- 109.5 Installing ONOS package - PASS
- 109.6 Set up ONOS secure SSH - PASS
- 109.7 Checking ONOS service - PASS
- 109.8 Starting ONOS CLI sessions - PASS
- 109.9 Checking ONOS nodes - PASS
- 109.10 Checking ONOS applications - PASS
- 109.11 Starting Mininet Topology - PASS
- 109.12 Verify host IP address assignment in ONOS - PASS
- 109.13 Verify IP address assignment from hosts - PASS
- 109.14 Verify reachability of connected internal IPv4 hosts - PASS
- 109.15 Verify reachability of connected internal IPv6 hosts - FAIL
- Verify reachability of connected internal IPv6 hosts: Fail
- 109.16 Stopping Mininet - PASS
- Skipping the rest of this case.
Case 201: Test switch failures with IPv4 hosts - PASS
- 201.1 Apply cell to environment - PASS
- 201.2 Uninstalling Atomix - PASS
- 201.3 Uninstalling ONOS package - PASS
- 201.4 Installing Atomix - PASS
- 201.5 Installing ONOS package - PASS
- 201.6 Set up ONOS secure SSH - PASS
- 201.7 Checking ONOS service - PASS
- 201.8 Starting ONOS CLI sessions - PASS
- 201.9 Checking ONOS nodes - PASS
- 201.10 Checking ONOS applications - PASS
- 201.11 Starting Mininet Topology - PASS
- 201.12 Verify host IP address assignment in ONOS - PASS
- 201.13 Verify IP address assignment from hosts - PASS
- 201.14 Verify reachability of connected internal IPv4 hosts - PASS
- 201.15 Kill ['spine101'] - PASS
- 201.16 Verify host IP address assignment in ONOS - PASS
- 201.17 Verify IP address assignment from hosts - PASS
- 201.18 Verify reachability of connected internal IPv4 hosts - PASS
- 201.19 Recovering ['spine101'] - PASS
- 201.20 Verify host IP address assignment in ONOS - PASS
- 201.21 Verify IP address assignment from hosts - PASS
- 201.22 Verify reachability of connected internal IPv4 hosts - PASS
- 201.23 Kill ['spine102'] - PASS
- 201.24 Verify host IP address assignment in ONOS - PASS
- 201.25 Verify IP address assignment from hosts - PASS
- 201.26 Verify reachability of connected internal IPv4 hosts - PASS
- 201.27 Recovering ['spine102'] - PASS
- 201.28 Verify host IP address assignment in ONOS - PASS
- 201.29 Verify IP address assignment from hosts - PASS
- 201.30 Verify reachability of connected internal IPv4 hosts - PASS
- 201.31 Stopping Mininet - PASS
Case 202: Test switch failures with IPv6 hosts - FAIL
- 202.1 Apply cell to environment - PASS
- 202.2 Uninstalling Atomix - PASS
- 202.3 Uninstalling ONOS package - PASS
- 202.4 Installing Atomix - PASS
- 202.5 Installing ONOS package - PASS
- 202.6 Set up ONOS secure SSH - PASS
- 202.7 Checking ONOS service - PASS
- 202.8 Starting ONOS CLI sessions - PASS
- 202.9 Checking ONOS nodes - PASS
- 202.10 Checking ONOS applications - PASS
- 202.11 Starting Mininet Topology - PASS
- 202.12 Verify host IP address assignment in ONOS - PASS
- 202.13 Verify IP address assignment from hosts - PASS
- 202.14 Verify reachability of connected internal IPv6 hosts - FAIL
- Verify reachability of connected internal IPv6 hosts: Fail
- 202.15 Stopping Mininet - PASS
- Skipping the rest of this case.
Case 203: Test switch failures with IPv4 and IPv6 hosts - FAIL
- 203.1 Apply cell to environment - PASS
- 203.2 Uninstalling Atomix - PASS
- 203.3 Uninstalling ONOS package - PASS
- 203.4 Installing Atomix - PASS
- 203.5 Installing ONOS package - PASS
- 203.6 Set up ONOS secure SSH - PASS
- 203.7 Checking ONOS service - PASS
- 203.8 Starting ONOS CLI sessions - PASS
- 203.9 Checking ONOS nodes - PASS
- 203.10 Checking ONOS applications - PASS
- 203.11 Starting Mininet Topology - PASS
- 203.12 Verify host IP address assignment in ONOS - PASS
- 203.13 Verify IP address assignment from hosts - PASS
- 203.14 Verify reachability of connected internal IPv4 hosts - PASS
- 203.15 Verify reachability of connected internal IPv6 hosts - FAIL
- Verify reachability of connected internal IPv6 hosts: Fail
- 203.16 Stopping Mininet - PASS
- Skipping the rest of this case.
Case 204: Test switch failures with IPv4 hosts including external hosts - PASS
- 204.1 Apply cell to environment - PASS
- 204.2 Uninstalling Atomix - PASS
- 204.3 Uninstalling ONOS package - PASS
- 204.4 Installing Atomix - PASS
- 204.5 Installing ONOS package - PASS
- 204.6 Set up ONOS secure SSH - PASS
- 204.7 Checking ONOS service - PASS
- 204.8 Starting ONOS CLI sessions - PASS
- 204.9 Checking ONOS nodes - PASS
- 204.10 Checking ONOS applications - PASS
- 204.11 Starting Mininet Topology - PASS
- 204.12 Verify host IP address assignment in ONOS - PASS
- 204.13 Verify IP address assignment from hosts - PASS
- 204.14 Verify reachability of connected internal IPv4 hosts - PASS
- 204.15 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 204.16 Kill ['spine101'] - PASS
- 204.17 Verify host IP address assignment in ONOS - PASS
- 204.18 Verify IP address assignment from hosts - PASS
- 204.19 Verify reachability of connected internal IPv4 hosts - PASS
- 204.20 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 204.21 Recovering ['spine101'] - PASS
- 204.22 Verify host IP address assignment in ONOS - PASS
- 204.23 Verify IP address assignment from hosts - PASS
- 204.24 Verify reachability of connected internal IPv4 hosts - PASS
- 204.25 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 204.26 Kill ['spine102'] - PASS
- 204.27 Verify host IP address assignment in ONOS - PASS
- 204.28 Verify IP address assignment from hosts - PASS
- 204.29 Verify reachability of connected internal IPv4 hosts - PASS
- 204.30 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 204.31 Recovering ['spine102'] - PASS
- 204.32 Verify host IP address assignment in ONOS - PASS
- 204.33 Verify IP address assignment from hosts - PASS
- 204.34 Verify reachability of connected internal IPv4 hosts - PASS
- 204.35 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 204.36 Stopping Mininet - PASS
Case 205: Test switch failures with IPv6 hosts including external hosts - FAIL
- 205.1 Apply cell to environment - PASS
- 205.2 Uninstalling Atomix - PASS
- 205.3 Uninstalling ONOS package - PASS
- 205.4 Installing Atomix - PASS
- 205.5 Installing ONOS package - PASS
- 205.6 Set up ONOS secure SSH - PASS
- 205.7 Checking ONOS service - PASS
- 205.8 Starting ONOS CLI sessions - PASS
- 205.9 Checking ONOS nodes - PASS
- 205.10 Checking ONOS applications - PASS
- 205.11 Starting Mininet Topology - PASS
- 205.12 Verify host IP address assignment in ONOS - PASS
- 205.13 Verify IP address assignment from hosts - PASS
- 205.14 Verify reachability of connected internal IPv6 hosts - FAIL
- Verify reachability of connected internal IPv6 hosts: Fail
- 205.15 Stopping Mininet - PASS
- Skipping the rest of this case.
Case 206: Test switch failures with IPv4 and IPv6 hosts including external hosts - FAIL
- 206.1 Apply cell to environment - PASS
- 206.2 Uninstalling Atomix - PASS
- 206.3 Uninstalling ONOS package - PASS
- 206.4 Installing Atomix - PASS
- 206.5 Installing ONOS package - PASS
- 206.6 Set up ONOS secure SSH - PASS
- 206.7 Checking ONOS service - PASS
- 206.8 Starting ONOS CLI sessions - PASS
- 206.9 Checking ONOS nodes - PASS
- 206.10 Checking ONOS applications - PASS
- 206.11 Starting Mininet Topology - PASS
- 206.12 Verify host IP address assignment in ONOS - PASS
- 206.13 Verify IP address assignment from hosts - PASS
- 206.14 Verify reachability of connected internal IPv4 hosts - PASS
- 206.15 Verify reachability of connected internal IPv6 hosts - FAIL
- Verify reachability of connected internal IPv6 hosts: Fail
- 206.16 Stopping Mininet - PASS
- Skipping the rest of this case.
Case 207: Test switch failures with IPv4 hosts including external hosts configured with route-add command - PASS
- 207.1 Apply cell to environment - PASS
- 207.2 Uninstalling Atomix - PASS
- 207.3 Uninstalling ONOS package - PASS
- 207.4 Installing Atomix - PASS
- 207.5 Installing ONOS package - PASS
- 207.6 Set up ONOS secure SSH - PASS
- 207.7 Checking ONOS service - PASS
- 207.8 Starting ONOS CLI sessions - PASS
- 207.9 Checking ONOS nodes - PASS
- 207.10 Checking ONOS applications - PASS
- 207.11 Starting Mininet Topology - PASS
- 207.12 Verify host IP address assignment in ONOS - PASS
- 207.13 Verify IP address assignment from hosts - PASS
- 207.14 Verify reachability of connected internal IPv4 hosts - PASS
- 207.15 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 207.16 Kill ['spine101'] - PASS
- 207.17 Verify host IP address assignment in ONOS - PASS
- 207.18 Verify IP address assignment from hosts - PASS
- 207.19 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 207.20 Recovering ['spine101'] - PASS
- 207.21 Verify host IP address assignment in ONOS - PASS
- 207.22 Verify IP address assignment from hosts - PASS
- 207.23 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 207.24 Kill ['spine102'] - PASS
- 207.25 Verify host IP address assignment in ONOS - PASS
- 207.26 Verify IP address assignment from hosts - PASS
- 207.27 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 207.28 Recovering ['spine102'] - PASS
- 207.29 Verify host IP address assignment in ONOS - PASS
- 207.30 Verify IP address assignment from hosts - PASS
- 207.31 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 207.32 Stopping Mininet - PASS
Case 208: Test switch failures with IPv6 hosts including external hosts configured with route-add command - FAIL
- 208.1 Apply cell to environment - PASS
- 208.2 Uninstalling Atomix - PASS
- 208.3 Uninstalling ONOS package - PASS
- 208.4 Installing Atomix - PASS
- 208.5 Installing ONOS package - PASS
- 208.6 Set up ONOS secure SSH - PASS
- 208.7 Checking ONOS service - PASS
- 208.8 Starting ONOS CLI sessions - PASS
- 208.9 Checking ONOS nodes - PASS
- 208.10 Checking ONOS applications - PASS
- 208.11 Starting Mininet Topology - PASS
- 208.12 Verify host IP address assignment in ONOS - PASS
- 208.13 Verify IP address assignment from hosts - PASS
- 208.14 Verify reachability of connected internal IPv6 hosts - FAIL
- Verify reachability of connected internal IPv6 hosts: Fail
- 208.15 Stopping Mininet - PASS
- Skipping the rest of this case.
Case 209: Test switch failures with IPv4 and IPv6 hosts including external hosts configured with route-add command - FAIL
- 209.1 Apply cell to environment - PASS
- 209.2 Uninstalling Atomix - PASS
- 209.3 Uninstalling ONOS package - PASS
- 209.4 Installing Atomix - PASS
- 209.5 Installing ONOS package - PASS
- 209.6 Set up ONOS secure SSH - PASS
- 209.7 Checking ONOS service - PASS
- 209.8 Starting ONOS CLI sessions - PASS
- 209.9 Checking ONOS nodes - PASS
- 209.10 Checking ONOS applications - PASS
- 209.11 Starting Mininet Topology - PASS
- 209.12 Verify host IP address assignment in ONOS - PASS
- 209.13 Verify IP address assignment from hosts - PASS
- 209.14 Verify reachability of connected internal IPv4 hosts - PASS
- 209.15 Verify reachability of connected internal IPv6 hosts - FAIL
- Verify reachability of connected internal IPv6 hosts: Fail
- 209.16 Stopping Mininet - PASS
- Skipping the rest of this case.
Case 301: Test onos failures with IPv4 hosts - PASS
- 301.1 Apply cell to environment - PASS
- 301.2 Uninstalling Atomix - PASS
- 301.3 Uninstalling ONOS package - PASS
- 301.4 Installing Atomix - PASS
- 301.5 Installing ONOS package - PASS
- 301.6 Set up ONOS secure SSH - PASS
- 301.7 Checking ONOS service - PASS
- 301.8 Starting ONOS CLI sessions - PASS
- 301.9 Checking ONOS nodes - PASS
- 301.10 Checking ONOS applications - PASS
- 301.11 Starting Mininet Topology - PASS
- 301.12 Verify host IP address assignment in ONOS - PASS
- 301.13 Verify IP address assignment from hosts - PASS
- 301.14 Verify reachability of connected internal IPv4 hosts - PASS
- 301.15 Killing ONOS instances with index(es): [0] - PASS
- 301.16 Check number of topology elements - PASS
- 301.17 Verify host IP address assignment in ONOS - PASS
- 301.18 Verify IP address assignment from hosts - PASS
- 301.19 Verify reachability of connected internal IPv4 hosts - PASS
- 301.20 Recovering ONOS instances with index(es): [0] - PASS
- 301.21 Checking if ONOS CLI is ready - PASS
- 301.22 Checking ONOS nodes - PASS
- 301.23 Check number of topology elements - PASS
- 301.24 Verify host IP address assignment in ONOS - PASS
- 301.25 Verify IP address assignment from hosts - PASS
- 301.26 Verify reachability of connected internal IPv4 hosts - PASS
- 301.27 Killing ONOS instances with index(es): [1] - PASS
- 301.28 Check number of topology elements - PASS
- 301.29 Verify host IP address assignment in ONOS - PASS
- 301.30 Verify IP address assignment from hosts - PASS
- 301.31 Verify reachability of connected internal IPv4 hosts - PASS
- 301.32 Recovering ONOS instances with index(es): [1] - PASS
- 301.33 Checking if ONOS CLI is ready - PASS
- 301.34 Checking ONOS nodes - PASS
- 301.35 Check number of topology elements - PASS
- 301.36 Verify host IP address assignment in ONOS - PASS
- 301.37 Verify IP address assignment from hosts - PASS
- 301.38 Verify reachability of connected internal IPv4 hosts - PASS
- 301.39 Killing ONOS instances with index(es): [2] - PASS
- 301.40 Check number of topology elements - PASS
- 301.41 Verify host IP address assignment in ONOS - PASS
- 301.42 Verify IP address assignment from hosts - PASS
- 301.43 Verify reachability of connected internal IPv4 hosts - PASS
- 301.44 Recovering ONOS instances with index(es): [2] - PASS
- 301.45 Checking if ONOS CLI is ready - PASS
- 301.46 Checking ONOS nodes - PASS
- 301.47 Check number of topology elements - PASS
- 301.48 Verify host IP address assignment in ONOS - PASS
- 301.49 Verify IP address assignment from hosts - PASS
- 301.50 Verify reachability of connected internal IPv4 hosts - PASS
- 301.51 Stopping Mininet - PASS
Case 302: Test onos failures with IPv6 hosts - FAIL
- 302.1 Apply cell to environment - PASS
- 302.2 Uninstalling Atomix - PASS
- 302.3 Uninstalling ONOS package - PASS
- 302.4 Installing Atomix - PASS
- 302.5 Installing ONOS package - PASS
- 302.6 Set up ONOS secure SSH - PASS
- 302.7 Checking ONOS service - PASS
- 302.8 Starting ONOS CLI sessions - PASS
- 302.9 Checking ONOS nodes - PASS
- 302.10 Checking ONOS applications - PASS
- 302.11 Starting Mininet Topology - PASS
- 302.12 Verify host IP address assignment in ONOS - PASS
- 302.13 Verify IP address assignment from hosts - PASS
- 302.14 Verify reachability of connected internal IPv6 hosts - FAIL
- Verify reachability of connected internal IPv6 hosts: Fail
- 302.15 Stopping Mininet - PASS
- Skipping the rest of this case.
Case 303: Test onos failures with IPv4 and IPv6 hosts - FAIL
- 303.1 Apply cell to environment - PASS
- 303.2 Uninstalling Atomix - PASS
- 303.3 Uninstalling ONOS package - PASS
- 303.4 Installing Atomix - PASS
- 303.5 Installing ONOS package - PASS
- 303.6 Set up ONOS secure SSH - PASS
- 303.7 Checking ONOS service - PASS
- 303.8 Starting ONOS CLI sessions - PASS
- 303.9 Checking ONOS nodes - PASS
- 303.10 Checking ONOS applications - PASS
- 303.11 Starting Mininet Topology - PASS
- 303.12 Verify host IP address assignment in ONOS - PASS
- 303.13 Verify IP address assignment from hosts - PASS
- 303.14 Verify reachability of connected internal IPv4 hosts - PASS
- 303.15 Verify reachability of connected internal IPv6 hosts - FAIL
- Verify reachability of connected internal IPv6 hosts: Fail
- 303.16 Stopping Mininet - PASS
- Skipping the rest of this case.
Case 304: Test onos failures with IPv4 hosts including external hosts - PASS
- 304.1 Apply cell to environment - PASS
- 304.2 Uninstalling Atomix - PASS
- 304.3 Uninstalling ONOS package - PASS
- 304.4 Installing Atomix - PASS
- 304.5 Installing ONOS package - PASS
- 304.6 Set up ONOS secure SSH - PASS
- 304.7 Checking ONOS service - PASS
- 304.8 Starting ONOS CLI sessions - PASS
- 304.9 Checking ONOS nodes - PASS
- 304.10 Checking ONOS applications - PASS
- 304.11 Starting Mininet Topology - PASS
- 304.12 Verify host IP address assignment in ONOS - PASS
- 304.13 Verify IP address assignment from hosts - PASS
- 304.14 Verify reachability of connected internal IPv4 hosts - PASS
- 304.15 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 304.16 Killing ONOS instances with index(es): [0] - PASS
- 304.17 Check number of topology elements - PASS
- 304.18 Verify host IP address assignment in ONOS - PASS
- 304.19 Verify IP address assignment from hosts - PASS
- 304.20 Verify reachability of connected internal IPv4 hosts - PASS
- 304.21 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 304.22 Recovering ONOS instances with index(es): [0] - PASS
- 304.23 Checking if ONOS CLI is ready - PASS
- 304.24 Checking ONOS nodes - PASS
- 304.25 Check number of topology elements - PASS
- 304.26 Verify host IP address assignment in ONOS - PASS
- 304.27 Verify IP address assignment from hosts - PASS
- 304.28 Verify reachability of connected internal IPv4 hosts - PASS
- 304.29 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 304.30 Killing ONOS instances with index(es): [1] - PASS
- 304.31 Check number of topology elements - PASS
- 304.32 Verify host IP address assignment in ONOS - PASS
- 304.33 Verify IP address assignment from hosts - PASS
- 304.34 Verify reachability of connected internal IPv4 hosts - PASS
- 304.35 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 304.36 Recovering ONOS instances with index(es): [1] - PASS
- 304.37 Checking if ONOS CLI is ready - PASS
- 304.38 Checking ONOS nodes - PASS
- 304.39 Check number of topology elements - PASS
- 304.40 Verify host IP address assignment in ONOS - PASS
- 304.41 Verify IP address assignment from hosts - PASS
- 304.42 Verify reachability of connected internal IPv4 hosts - PASS
- 304.43 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 304.44 Killing ONOS instances with index(es): [2] - PASS
- 304.45 Check number of topology elements - PASS
- 304.46 Verify host IP address assignment in ONOS - PASS
- 304.47 Verify IP address assignment from hosts - PASS
- 304.48 Verify reachability of connected internal IPv4 hosts - PASS
- 304.49 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 304.50 Recovering ONOS instances with index(es): [2] - PASS
- 304.51 Checking if ONOS CLI is ready - PASS
- 304.52 Checking ONOS nodes - PASS
- 304.53 Check number of topology elements - PASS
- 304.54 Verify host IP address assignment in ONOS - PASS
- 304.55 Verify IP address assignment from hosts - PASS
- 304.56 Verify reachability of connected internal IPv4 hosts - PASS
- 304.57 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 304.58 Stopping Mininet - PASS
Case 305: Test onos failures with IPv6 hosts including external hosts - FAIL
- 305.1 Apply cell to environment - PASS
- 305.2 Uninstalling Atomix - PASS
- 305.3 Uninstalling ONOS package - PASS
- 305.4 Installing Atomix - PASS
- 305.5 Installing ONOS package - PASS
- 305.6 Set up ONOS secure SSH - PASS
- 305.7 Checking ONOS service - PASS
- 305.8 Starting ONOS CLI sessions - PASS
- 305.9 Checking ONOS nodes - PASS
- 305.10 Checking ONOS applications - PASS
- 305.11 Starting Mininet Topology - PASS
- 305.12 Verify host IP address assignment in ONOS - PASS
- 305.13 Verify IP address assignment from hosts - PASS
- 305.14 Verify reachability of connected internal IPv6 hosts - FAIL
- Verify reachability of connected internal IPv6 hosts: Fail
- 305.15 Stopping Mininet - PASS
- Skipping the rest of this case.
Case 306: Test onos failures with IPv4 and IPv6 hosts including external hosts - FAIL
- 306.1 Apply cell to environment - PASS
- 306.2 Uninstalling Atomix - PASS
- 306.3 Uninstalling ONOS package - PASS
- 306.4 Installing Atomix - PASS
- 306.5 Installing ONOS package - PASS
- 306.6 Set up ONOS secure SSH - PASS
- 306.7 Checking ONOS service - PASS
- 306.8 Starting ONOS CLI sessions - PASS
- 306.9 Checking ONOS nodes - PASS
- 306.10 Checking ONOS applications - PASS
- 306.11 Starting Mininet Topology - PASS
- 306.12 Verify host IP address assignment in ONOS - PASS
- 306.13 Verify IP address assignment from hosts - PASS
- 306.14 Verify reachability of connected internal IPv4 hosts - PASS
- 306.15 Verify reachability of connected internal IPv6 hosts - FAIL
- Verify reachability of connected internal IPv6 hosts: Fail
- 306.16 Stopping Mininet - PASS
- Skipping the rest of this case.
Case 307: Test onos failures with IPv4 hosts including external hosts configured with route-add command - PASS
- 307.1 Apply cell to environment - PASS
- 307.2 Uninstalling Atomix - PASS
- 307.3 Uninstalling ONOS package - PASS
- 307.4 Installing Atomix - PASS
- 307.5 Installing ONOS package - PASS
- 307.6 Set up ONOS secure SSH - PASS
- 307.7 Checking ONOS service - PASS
- 307.8 Starting ONOS CLI sessions - PASS
- 307.9 Checking ONOS nodes - PASS
- 307.10 Checking ONOS applications - PASS
- 307.11 Starting Mininet Topology - PASS
- 307.12 Verify host IP address assignment in ONOS - PASS
- 307.13 Verify IP address assignment from hosts - PASS
- 307.14 Verify reachability of connected internal IPv4 hosts - PASS
- 307.15 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 307.16 Killing ONOS instances with index(es): [0] - PASS
- 307.17 Check number of topology elements - PASS
- 307.18 Verify host IP address assignment in ONOS - PASS
- 307.19 Verify IP address assignment from hosts - PASS
- 307.20 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 307.21 Recovering ONOS instances with index(es): [0] - PASS
- 307.22 Checking if ONOS CLI is ready - PASS
- 307.23 Checking ONOS nodes - PASS
- 307.24 Check number of topology elements - PASS
- 307.25 Verify host IP address assignment in ONOS - PASS
- 307.26 Verify IP address assignment from hosts - PASS
- 307.27 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 307.28 Killing ONOS instances with index(es): [1] - PASS
- 307.29 Check number of topology elements - PASS
- 307.30 Verify host IP address assignment in ONOS - PASS
- 307.31 Verify IP address assignment from hosts - PASS
- 307.32 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 307.33 Recovering ONOS instances with index(es): [1] - PASS
- 307.34 Checking if ONOS CLI is ready - PASS
- 307.35 Checking ONOS nodes - PASS
- 307.36 Check number of topology elements - PASS
- 307.37 Verify host IP address assignment in ONOS - PASS
- 307.38 Verify IP address assignment from hosts - PASS
- 307.39 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 307.40 Killing ONOS instances with index(es): [2] - PASS
- 307.41 Check number of topology elements - PASS
- 307.42 Verify host IP address assignment in ONOS - PASS
- 307.43 Verify IP address assignment from hosts - PASS
- 307.44 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 307.45 Recovering ONOS instances with index(es): [2] - PASS
- 307.46 Checking if ONOS CLI is ready - PASS
- 307.47 Checking ONOS nodes - PASS
- 307.48 Check number of topology elements - PASS
- 307.49 Verify host IP address assignment in ONOS - PASS
- 307.50 Verify IP address assignment from hosts - PASS
- 307.51 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS
- 307.52 Stopping Mininet - PASS
Case 308: Test onos failures with IPv6 hosts including external hosts configured with route-add command - FAIL
- 308.1 Apply cell to environment - PASS
- 308.2 Uninstalling Atomix - PASS
- 308.3 Uninstalling ONOS package - PASS
- 308.4 Installing Atomix - PASS
- 308.5 Installing ONOS package - PASS
- 308.6 Set up ONOS secure SSH - PASS
- 308.7 Checking ONOS service - PASS
- 308.8 Starting ONOS CLI sessions - PASS
- 308.9 Checking ONOS nodes - PASS
- 308.10 Checking ONOS applications - PASS
- 308.11 Starting Mininet Topology - PASS
- 308.12 Verify host IP address assignment in ONOS - PASS
- 308.13 Verify IP address assignment from hosts - PASS
- 308.14 Verify reachability of connected internal IPv6 hosts - FAIL
- Verify reachability of connected internal IPv6 hosts: Fail
- 308.15 Stopping Mininet - PASS
- Skipping the rest of this case.
Case 309: Test onos failures with IPv4 and IPv6 hosts including external hosts configured with route-add command - FAIL
- 309.1 Apply cell to environment - PASS
- 309.2 Uninstalling Atomix - PASS
- 309.3 Uninstalling ONOS package - PASS
- 309.4 Installing Atomix - PASS
- 309.5 Installing ONOS package - PASS
- 309.6 Set up ONOS secure SSH - PASS
- 309.7 Checking ONOS service - PASS
- 309.8 Starting ONOS CLI sessions - PASS
- 309.9 Checking ONOS nodes - PASS
- 309.10 Checking ONOS applications - PASS
- 309.11 Starting Mininet Topology - PASS
- 309.12 Verify host IP address assignment in ONOS - PASS
- 309.13 Verify IP address assignment from hosts - PASS
- 309.14 Verify reachability of connected internal IPv4 hosts - PASS
- 309.15 Verify reachability of connected internal IPv6 hosts - FAIL
- Verify reachability of connected internal IPv6 hosts: Fail
- 309.16 Stopping Mininet - PASS
- Skipping the rest of this case.
...
- Skipping the rest of this case.