  • 104.1 Apply cell to environment - PASS (tick)
  • 104.2 Uninstalling Atomix - PASS (tick)
  • 104.3 Uninstalling ONOS package - PASS (tick)
  • 104.4 Installing Atomix - PASS (tick)
  • 104.5 Installing ONOS package - PASS (tick)
  • 104.6 Set up ONOS secure SSH - PASS (tick)
  • 104.7 Checking ONOS service - PASS (tick)
  • 104.8 Starting ONOS CLI sessions - PASS (tick)
  • 104.9 Checking ONOS nodes - PASS (tick)
  • 104.10 Checking ONOS applications - PASS (tick)
  • 104.11 Starting Mininet Topology - PASS (tick)
  • 104.12 Verify host IP address assignment in ONOS - PASS (tick)
  • 104.13 Verify IP address assignment from hosts - PASS (tick)
  • 104.14 Verify reachability of connected internal IPv4 hosts - PASS (tick) 104.15 FAIL (error)
    • Verify reachability
    from
    • of connected internal IPv4 hosts: Fail
  • 104.15 Stopping Mininet to external IPv4 hosts - PASS (tick)
  • 104.16 Killing a batch of links [['spine103', 'spine101'], ['leaf2', 'spine101'], ['leaf3', 'spine101'], ['leaf4', 'spine101'], ['leaf5', 'spine101']] - PASS (tick)
  • 104.17 Verify host IP address assignment in ONOS - PASS (tick)
  • 104.18 Verify IP address assignment from hosts - PASS (tick)
  • 104.19 Verify reachability of connected internal IPv4 hosts - FAIL (error)
    • Verify reachability of connected internal IPv4 hosts: Fail
  • 104.20 Stopping Mininet - PASS (tick)
    • Skipping the rest of this case.

Case 105: Test link failures with IPv6 hosts including external hosts - FAIL

  • 105.1 Apply cell to environment - PASS (tick)
  • 105.2 Uninstalling Atomix - PASS (tick)
  • 105.3 Uninstalling ONOS package - PASS (tick)
  • 105.4 Installing Atomix - PASS (tick)
  • 105.5 Installing ONOS package - PASS (tick)
  • 105.6 Set up ONOS secure SSH - PASS (tick)
  • 105.7 Checking ONOS service - PASS (tick)
  • 105.8 Starting ONOS CLI sessions - PASS (tick)
  • 105.9 Checking ONOS nodes - PASS (tick)
  • 105.10 Checking ONOS applications - PASS (tick)
  • 105.11 Starting Mininet Topology - PASS (tick)
  • 105.12 Verify host IP address assignment in ONOS - PASS (tick)
  • 105.13 Verify IP address assignment from hosts - PASS (tick)
  • 105.14 Verify reachability of connected internal IPv6 hosts - FAIL (error)
    • Verify reachability of connected internal IPv6 hosts: Fail
  • 105.15 Stopping Mininet - PASS (tick)
    • Skipping the rest of this case.

Case 106: Test link failures with IPv4 and IPv6 hosts including external hosts - FAIL

  • 106.1 Apply cell to environment - PASS (tick)
  • 106.2 Uninstalling Atomix - PASS (tick)
  • 106.3 Uninstalling ONOS package - PASS (tick)
  • 106.4 Installing Atomix - PASS (tick)
  • 106.5 Installing ONOS package - PASS (tick)
  • 106.6 Set up ONOS secure SSH - PASS (tick)
  • 106.7 Checking ONOS service - PASS (tick)
  • 106.8 Starting ONOS CLI sessions - PASS (tick)
  • 106.9 Checking ONOS nodes - PASS (tick)
  • 106.10 Checking ONOS applications - PASS (tick)
  • 106.11 Starting Mininet Topology - PASS (tick)
  • 106.12 Verify host IP address assignment in ONOS - PASS (tick)
  • 106.13 Verify IP address assignment from hosts - PASS (tick)
  • 106.14 Verify reachability of connected internal IPv4 hosts - PASS (tick)
  • 106.15 Verify reachability of connected internal IPv6 hosts - FAIL (error)
    • Verify reachability of connected internal IPv6 hosts: Fail
  • 106.16 Stopping Mininet - PASS (tick)
    • Skipping the rest of this case.

Case 107: Test link failures with IPv4 hosts including external hosts configured with route-add command - PASS

  • 107.1 Apply cell to environment - PASS (tick)
  • 107.2 Uninstalling Atomix - PASS (tick)
  • 107.3 Uninstalling ONOS package - PASS (tick)
  • 107.4 Installing Atomix - PASS (tick)
  • 107.5 Installing ONOS package - PASS (tick)
  • 107.6 Set up ONOS secure SSH - PASS (tick)
  • 107.7 Checking ONOS service - PASS (tick)
  • 107.8 Starting ONOS CLI sessions - PASS (tick)
  • 107.9 Checking ONOS nodes - PASS (tick)
  • 107.10 Checking ONOS applications - PASS (tick)
  • 107.11 Starting Mininet Topology - PASS (tick)
  • 107.12 Verify host IP address assignment in ONOS - PASS (tick)
  • 107.13 Verify IP address assignment from hosts - PASS (tick)
  • 107.14 Verify reachability of connected internal IPv4 hosts - PASS (tick)
  • 107.15 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS (tick)
  • 107.16 Killing a batch of links [['spine103', 'spine101'], ['leaf2', 'spine101'], ['leaf3', 'spine101'], ['leaf4', 'spine101'], ['leaf5', 'spine101']] - PASS (tick)
  • 107.17 Verify host IP address assignment in ONOS - PASS (tick)
  • 107.18 Verify IP address assignment from hosts - PASS (tick)
  • 107.19 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS (tick)
  • 107.20 Restoring a batch of links [['spine103', 'spine101'], ['leaf2', 'spine101'], ['leaf3', 'spine101'], ['leaf4', 'spine101'], ['leaf5', 'spine101']] - PASS (tick)
  • 107.21 Verify host IP address assignment in ONOS - PASS (tick)
  • 107.22 Verify IP address assignment from hosts - PASS (tick)
  • 107.23 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS (tick)
  • 107.24 Killing a batch of links [['spine104', 'spine102'], ['leaf2', 'spine102'], ['leaf3', 'spine102'], ['leaf4', 'spine102'], ['leaf5', 'spine102']] - PASS (tick)
  • 107.25 Verify host IP address assignment in ONOS - PASS (tick)
  • 107.26 Verify IP address assignment from hosts - PASS (tick)
  • 107.27 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS (tick)
  • 107.28 Restoring a batch of links [['spine104', 'spine102'], ['leaf2', 'spine102'], ['leaf3', 'spine102'], ['leaf4', 'spine102'], ['leaf5', 'spine102']] - PASS (tick)
  • 107.29 Verify host IP address assignment in ONOS - PASS (tick)
  • 107.30 Verify IP address assignment from hosts - PASS (tick)
  • 107.31 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS (tick)
  • 107.32 Stopping Mininet - PASS (tick)

Case 108: Test link failures with IPv6 hosts including external hosts configured with route-add command - FAIL

  • 108.1 Apply cell to environment - PASS (tick)
  • 108.2 Uninstalling Atomix - PASS (tick)
  • 108.3 Uninstalling ONOS package - PASS (tick)
  • 108.4 Installing Atomix - PASS (tick)
  • 108.5 Installing ONOS package - PASS (tick)
  • 108.6 Set up ONOS secure SSH - PASS (tick)
  • 108.7 Checking ONOS service - PASS (tick)
  • 108.8 Starting ONOS CLI sessions - PASS (tick)
  • 108.9 Checking ONOS nodes - PASS (tick)
  • 108.10 Checking ONOS applications - PASS (tick)
  • 108.11 Starting Mininet Topology - PASS (tick)
  • 108.12 Verify host IP address assignment in ONOS - PASS (tick)
  • 108.13 Verify IP address assignment from hosts - PASS (tick)
  • 108.14 Verify reachability of connected internal IPv6 hosts - FAIL (error)
    • Verify reachability of connected internal IPv6 hosts: Fail
  • 108.15 Stopping Mininet - PASS (tick)
    • Skipping the rest of this case.

Case 109: Test link failures with IPv4 and IPv6 hosts including external hosts configured with route-add command - FAIL

  • 109.1 Apply cell to environment - PASS (tick)
  • 109.2 Uninstalling Atomix - PASS (tick)
  • 109.3 Uninstalling ONOS package - PASS (tick)
  • 109.4 Installing Atomix - PASS (tick)
  • 109.5 Installing ONOS package - PASS (tick)
  • 109.6 Set up ONOS secure SSH - PASS (tick)
  • 109.7 Checking ONOS service - PASS (tick)
  • 109.8 Starting ONOS CLI sessions - PASS (tick)
  • 109.9 Checking ONOS nodes - PASS (tick)
  • 109.10 Checking ONOS applications - PASS (tick)
  • 109.11 Starting Mininet Topology - PASS (tick)
  • 109.12 Verify host IP address assignment in ONOS - PASS (tick)
  • 109.13 Verify IP address assignment from hosts - PASS (tick)
  • 109.14 Verify reachability of connected internal IPv4 hosts - PASS (tick)
  • 109.15 Verify reachability of connected internal IPv6 hosts - FAIL (error)
    • Verify reachability of connected internal IPv6 hosts: Fail
  • 109.16 Stopping Mininet - PASS (tick)
    • Skipping the rest of this case.

Case 201: Test switch failures with IPv4 hosts - PASS

  • 201.1 Apply cell to environment - PASS (tick)
  • 201.2 Uninstalling Atomix - PASS (tick)
  • 201.3 Uninstalling ONOS package - PASS (tick)
  • 201.4 Installing Atomix - PASS (tick)
  • 201.5 Installing ONOS package - PASS (tick)
  • 201.6 Set up ONOS secure SSH - PASS (tick)
  • 201.7 Checking ONOS service - PASS (tick)
  • 201.8 Starting ONOS CLI sessions - PASS (tick)
  • 201.9 Checking ONOS nodes - PASS (tick)
  • 201.10 Checking ONOS applications - PASS (tick)
  • 201.11 Starting Mininet Topology - PASS (tick)
  • 201.12 Verify host IP address assignment in ONOS - PASS (tick)
  • 201.13 Verify IP address assignment from hosts - PASS (tick)
  • 201.14 Verify reachability of connected internal IPv4 hosts - PASS (tick)
  • 201.15 Kill ['spine101'] - PASS (tick)
  • 201.16 Verify host IP address assignment in ONOS - PASS (tick)
  • 201.17 Verify IP address assignment from hosts - PASS (tick)
  • 201.18 Verify reachability of connected internal IPv4 hosts - PASS (tick)
  • 201.19 Recovering ['spine101'] - PASS (tick)
  • 201.20 Verify host IP address assignment in ONOS - PASS (tick)
  • 201.21 Verify IP address assignment from hosts - PASS (tick)
  • 201.22 Verify reachability of connected internal IPv4 hosts - PASS (tick)
  • 201.23 Kill ['spine102'] - PASS (tick)
  • 201.24 Verify host IP address assignment in ONOS - PASS (tick)
  • 201.25 Verify IP address assignment from hosts - PASS (tick)
  • 201.26 Verify reachability of connected internal IPv4 hosts - PASS (tick)
  • 201.27 Recovering ['spine102'] - PASS (tick)
  • 201.28 Verify host IP address assignment in ONOS - PASS (tick)
  • 201.29 Verify IP address assignment from hosts - PASS (tick)
  • 201.30 Verify reachability of connected internal IPv4 hosts - PASS (tick)
  • 201.31 Stopping Mininet - PASS (tick)

Case 202: Test switch failures with IPv6 hosts - FAIL

  • 202.1 Apply cell to environment - PASS (tick)
  • 202.2 Uninstalling Atomix - PASS (tick)
  • 202.3 Uninstalling ONOS package - PASS (tick)
  • 202.4 Installing Atomix - PASS (tick)
  • 202.5 Installing ONOS package - PASS (tick)
  • 202.6 Set up ONOS secure SSH - PASS (tick)
  • 202.7 Checking ONOS service - PASS (tick)
  • 202.8 Starting ONOS CLI sessions - PASS (tick)
  • 202.9 Checking ONOS nodes - PASS (tick)
  • 202.10 Checking ONOS applications - PASS (tick)
  • 202.11 Starting Mininet Topology - PASS (tick)
  • 202.12 Verify host IP address assignment in ONOS - PASS (tick)
  • 202.13 Verify IP address assignment from hosts - PASS (tick)
  • 202.14 Verify reachability of connected internal IPv6 hosts - FAIL (error)
    • Verify reachability of connected internal IPv6 hosts: Fail
  • 202.15 Stopping Mininet - PASS (tick)
    • Skipping the rest of this case.

Case 203: Test switch failures with IPv4 and IPv6 hosts - FAIL

  • 203.1 Apply cell to environment - PASS (tick)
  • 203.2 Uninstalling Atomix - PASS (tick)
  • 203.3 Uninstalling ONOS package - PASS (tick)
  • 203.4 Installing Atomix - PASS (tick)
  • 203.5 Installing ONOS package - PASS (tick)
  • 203.6 Set up ONOS secure SSH - PASS (tick)
  • 203.7 Checking ONOS service - PASS (tick)
  • 203.8 Starting ONOS CLI sessions - PASS (tick)
  • 203.9 Checking ONOS nodes - PASS (tick)
  • 203.10 Checking ONOS applications - PASS (tick)
  • 203.11 Starting Mininet Topology - PASS (tick)
  • 203.12 Verify host IP address assignment in ONOS - PASS (tick)
  • 203.13 Verify IP address assignment from hosts - PASS (tick)
  • 203.14 Verify reachability of connected internal IPv4 hosts - PASS (tick)
  • 203.15 Verify reachability of connected internal IPv6 hosts - FAIL (error)
    • Verify reachability of connected internal IPv6 hosts: Fail
  • 203.16 Stopping Mininet - PASS (tick)
    • Skipping the rest of this case.

Case 204: Test switch failures with IPv4 hosts including external hosts - PASS

  • 204.1 Apply cell to environment - PASS (tick)
  • 204.2 Uninstalling Atomix - PASS (tick)
  • 204.3 Uninstalling ONOS package - PASS (tick)
  • 204.4 Installing Atomix - PASS (tick)
  • 204.5 Installing ONOS package - PASS (tick)
  • 204.6 Set up ONOS secure SSH - PASS (tick)
  • 204.7 Checking ONOS service - PASS (tick)
  • 204.8 Starting ONOS CLI sessions - PASS (tick)
  • 204.9 Checking ONOS nodes - PASS (tick)
  • 204.10 Checking ONOS applications - PASS (tick)
  • 204.11 Starting Mininet Topology - PASS (tick)
  • 204.12 Verify host IP address assignment in ONOS - PASS (tick)
  • 204.13 Verify IP address assignment from hosts - PASS (tick)
  • 204.14 Verify reachability of connected internal IPv4 hosts - PASS (tick)
  • 204.15 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS (tick)
  • 204.16 Kill ['spine101'] - PASS (tick)
  • 204.17 Verify host IP address assignment in ONOS - PASS (tick)
  • 204.18 Verify IP address assignment from hosts - PASS (tick)
  • 204.19 Verify reachability of connected internal IPv4 hosts - PASS (tick)
  • 204.20 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS (tick)
  • 204.21 Recovering ['spine101'] - PASS (tick)
  • 204.22 Verify host IP address assignment in ONOS - PASS (tick)
  • 204.23 Verify IP address assignment from hosts - PASS (tick)
  • 204.24 Verify reachability of connected internal IPv4 hosts - PASS (tick)
  • 204.25 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS (tick)
  • 204.26 Kill ['spine102'] - PASS (tick)
  • 204.27 Verify host IP address assignment in ONOS - PASS (tick)
  • 204.28 Verify IP address assignment from hosts - PASS (tick)
  • 204.29 Verify reachability of connected internal IPv4 hosts - PASS (tick)
  • 204.30 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS (tick)
  • 204.31 Recovering ['spine102'] - PASS (tick)
  • 204.32 Verify host IP address assignment in ONOS - PASS (tick)
  • 204.33 Verify IP address assignment from hosts - PASS (tick)
  • 204.34 Verify reachability of connected internal IPv4 hosts - PASS (tick)
  • 204.35 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS (tick)
  • 204.36 Stopping Mininet - PASS (tick)

Case 205: Test switch failures with IPv6 hosts including external hosts - FAIL

  • 205.1 Apply cell to environment - PASS (tick)
  • 205.2 Uninstalling Atomix - PASS (tick)
  • 205.3 Uninstalling ONOS package - PASS (tick)
  • 205.4 Installing Atomix - PASS (tick)
  • 205.5 Installing ONOS package - PASS (tick)
  • 205.6 Set up ONOS secure SSH - PASS (tick)
  • 205.7 Checking ONOS service - PASS (tick)
  • 205.8 Starting ONOS CLI sessions - PASS (tick)
  • 205.9 Checking ONOS nodes - PASS (tick)
  • 205.10 Checking ONOS applications - PASS (tick)
  • 205.11 Starting Mininet Topology - PASS (tick)
  • 205.12 Verify host IP address assignment in ONOS - PASS (tick)
  • 205.13 Verify IP address assignment from hosts - PASS (tick)
  • 205.14 Verify reachability of connected internal IPv6 hosts - FAIL (error)
    • Verify reachability of connected internal IPv6 hosts: Fail
  • 205.15 Stopping Mininet - PASS (tick)
    • Skipping the rest of this case.

Case 206: Test switch failures with IPv4 and IPv6 hosts including external hosts - FAIL

  • 206.1 Apply cell to environment - PASS (tick)
  • 206.2 Uninstalling Atomix - PASS (tick)
  • 206.3 Uninstalling ONOS package - PASS (tick)
  • 206.4 Installing Atomix - PASS (tick)
  • 206.5 Installing ONOS package - PASS (tick)
  • 206.6 Set up ONOS secure SSH - PASS (tick)
  • 206.7 Checking ONOS service - PASS (tick)
  • 206.8 Starting ONOS CLI sessions - PASS (tick)
  • 206.9 Checking ONOS nodes - PASS (tick)
  • 206.10 Checking ONOS applications - PASS (tick)
  • 206.11 Starting Mininet Topology - PASS (tick)
  • 206.12 Verify host IP address assignment in ONOS - PASS (tick)
  • 206.13 Verify IP address assignment from hosts - PASS (tick)
  • 206.14 Verify reachability of connected internal IPv4 hosts - PASS (tick)
  • 206.15 Verify reachability of connected internal IPv6 hosts - FAIL (error)
    • Verify reachability of connected internal IPv6 hosts: Fail
  • 206.16 Stopping Mininet - PASS (tick)
    • Skipping the rest of this case.

Case 207: Test switch failures with IPv4 hosts including external hosts configured with route-add command - PASS

  • 207.1 Apply cell to environment - PASS (tick)
  • 207.2 Uninstalling Atomix - PASS (tick)
  • 207.3 Uninstalling ONOS package - PASS (tick)
  • 207.4 Installing Atomix - PASS (tick)
  • 207.5 Installing ONOS package - PASS (tick)
  • 207.6 Set up ONOS secure SSH - PASS (tick)
  • 207.7 Checking ONOS service - PASS (tick)
  • 207.8 Starting ONOS CLI sessions - PASS (tick)
  • 207.9 Checking ONOS nodes - PASS (tick)
  • 207.10 Checking ONOS applications - PASS (tick)
  • 207.11 Starting Mininet Topology - PASS (tick)
  • 207.12 Verify host IP address assignment in ONOS - PASS (tick)
  • 207.13 Verify IP address assignment from hosts - PASS (tick)
  • 207.14 Verify reachability of connected internal IPv4 hosts - PASS (tick)
  • 207.15 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS (tick)
  • 207.16 Kill ['spine101'] - PASS (tick)
  • 207.17 Verify host IP address assignment in ONOS - PASS (tick)
  • 207.18 Verify IP address assignment from hosts - PASS (tick)
  • 207.19 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS (tick)
  • 207.20 Recovering ['spine101'] - PASS (tick)
  • 207.21 Verify host IP address assignment in ONOS - PASS (tick)
  • 207.22 Verify IP address assignment from hosts - PASS (tick)
  • 207.23 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS (tick)
  • 207.24 Kill ['spine102'] - PASS (tick)
  • 207.25 Verify host IP address assignment in ONOS - PASS (tick)
  • 207.26 Verify IP address assignment from hosts - PASS (tick)
  • 207.27 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS (tick)
  • 207.28 Recovering ['spine102'] - PASS (tick)
  • 207.29 Verify host IP address assignment in ONOS - PASS (tick)
  • 207.30 Verify IP address assignment from hosts - PASS (tick)
  • 207.31 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS (tick)
  • 207.32 Stopping Mininet - PASS (tick)

Case 208: Test switch failures with IPv6 hosts including external hosts configured with route-add command - FAIL

  • 208.1 Apply cell to environment - PASS (tick)
  • 208.2 Uninstalling Atomix - PASS (tick)
  • 208.3 Uninstalling ONOS package - PASS (tick)
  • 208.4 Installing Atomix - PASS (tick)
  • 208.5 Installing ONOS package - PASS (tick)
  • 208.6 Set up ONOS secure SSH - PASS (tick)
  • 208.7 Checking ONOS service - PASS (tick)
  • 208.8 Starting ONOS CLI sessions - PASS (tick)
  • 208.9 Checking ONOS nodes - PASS (tick)
  • 208.10 Checking ONOS applications - PASS (tick)
  • 208.11 Starting Mininet Topology - PASS (tick)
  • 208.12 Verify host IP address assignment in ONOS - PASS (tick)
  • 208.13 Verify IP address assignment from hosts - PASS (tick)
  • 208.14 Verify reachability of connected internal IPv6 hosts - FAIL (error)
    • Verify reachability of connected internal IPv6 hosts: Fail
  • 208.15 Stopping Mininet - PASS (tick)
    • Skipping the rest of this case.

Case 209: Test switch failures with IPv4 and IPv6 hosts including external hosts configured with route-add command - FAIL

  • 209.1 Apply cell to environment - PASS (tick)
  • 209.2 Uninstalling Atomix - PASS (tick)
  • 209.3 Uninstalling ONOS package - PASS (tick)
  • 209.4 Installing Atomix - PASS (tick)
  • 209.5 Installing ONOS package - PASS (tick)
  • 209.6 Set up ONOS secure SSH - PASS (tick)
  • 209.7 Checking ONOS service - PASS (tick)
  • 209.8 Starting ONOS CLI sessions - PASS (tick)
  • 209.9 Checking ONOS nodes - PASS (tick)
  • 209.10 Checking ONOS applications - PASS (tick)
  • 209.11 Starting Mininet Topology - PASS (tick)
  • 209.12 Verify host IP address assignment in ONOS - PASS (tick)
  • 209.13 Verify IP address assignment from hosts - PASS (tick)
  • 209.14 Verify reachability of connected internal IPv4 hosts - PASS (tick)
  • 209.15 Verify reachability of connected internal IPv6 hosts - FAIL (error)
    • Verify reachability of connected internal IPv6 hosts: Fail
  • 209.16 Stopping Mininet - PASS (tick)
    • Skipping the rest of this case.

Case 301: Test onos failures with IPv4 hosts - PASS

  • 301.1 Apply cell to environment - PASS (tick)
  • 301.2 Uninstalling Atomix - PASS (tick)
  • 301.3 Uninstalling ONOS package - PASS (tick)
  • 301.4 Installing Atomix - PASS (tick)
  • 301.5 Installing ONOS package - PASS (tick)
  • 301.6 Set up ONOS secure SSH - PASS (tick)
  • 301.7 Checking ONOS service - PASS (tick)
  • 301.8 Starting ONOS CLI sessions - PASS (tick)
  • 301.9 Checking ONOS nodes - PASS (tick)
  • 301.10 Checking ONOS applications - PASS (tick)
  • 301.11 Starting Mininet Topology - PASS (tick)
  • 301.12 Verify host IP address assignment in ONOS - PASS (tick)
  • 301.13 Verify IP address assignment from hosts - PASS (tick)
  • 301.14 Verify reachability of connected internal IPv4 hosts - PASS (tick)
  • 301.15 Killing ONOS instances with index(es): [0] - PASS (tick)
  • 301.16 Check number of topology elements - PASS (tick)
  • 301.17 Verify host IP address assignment in ONOS - PASS (tick)
  • 301.18 Verify IP address assignment from hosts - PASS (tick)
  • 301.19 Verify reachability of connected internal IPv4 hosts - PASS (tick)
  • 301.20 Recovering ONOS instances with index(es): [0] - PASS (tick)
  • 301.21 Checking if ONOS CLI is ready - PASS (tick)
  • 301.22 Checking ONOS nodes - PASS (tick)
  • 301.23 Check number of topology elements - PASS (tick)
  • 301.24 Verify host IP address assignment in ONOS - PASS (tick)
  • 301.25 Verify IP address assignment from hosts - PASS (tick)
  • 301.26 Verify reachability of connected internal IPv4 hosts - PASS (tick)
  • 301.27 Killing ONOS instances with index(es): [1] - PASS (tick)
  • 301.28 Check number of topology elements - PASS (tick)
  • 301.29 Verify host IP address assignment in ONOS - PASS (tick)
  • 301.30 Verify IP address assignment from hosts - PASS (tick)
  • 301.31 Verify reachability of connected internal IPv4 hosts - PASS (tick)
  • 301.32 Recovering ONOS instances with index(es): [1] - PASS (tick)
  • 301.33 Checking if ONOS CLI is ready - PASS (tick)
  • 301.34 Checking ONOS nodes - PASS (tick)
  • 301.35 Check number of topology elements - PASS (tick)
  • 301.36 Verify host IP address assignment in ONOS - PASS (tick)
  • 301.37 Verify IP address assignment from hosts - PASS (tick)
  • 301.38 Verify reachability of connected internal IPv4 hosts - PASS (tick)
  • 301.39 Killing ONOS instances with index(es): [2] - PASS (tick)
  • 301.40 Check number of topology elements - PASS (tick)
  • 301.41 Verify host IP address assignment in ONOS - PASS (tick)
  • 301.42 Verify IP address assignment from hosts - PASS (tick)
  • 301.43 Verify reachability of connected internal IPv4 hosts - PASS (tick)
  • 301.44 Recovering ONOS instances with index(es): [2] - PASS (tick)
  • 301.45 Checking if ONOS CLI is ready - PASS (tick)
  • 301.46 Checking ONOS nodes - PASS (tick)
  • 301.47 Check number of topology elements - PASS (tick)
  • 301.48 Verify host IP address assignment in ONOS - PASS (tick)
  • 301.49 Verify IP address assignment from hosts - PASS (tick)
  • 301.50 Verify reachability of connected internal IPv4 hosts - PASS (tick)
  • 301.51 Stopping Mininet - PASS (tick)

Case 302: Test onos failures with IPv6 hosts - FAIL

  • 302.1 Apply cell to environment - PASS (tick)
  • 302.2 Uninstalling Atomix - PASS (tick)
  • 302.3 Uninstalling ONOS package - PASS (tick)
  • 302.4 Installing Atomix - PASS (tick)
  • 302.5 Installing ONOS package - PASS (tick)
  • 302.6 Set up ONOS secure SSH - PASS (tick)
  • 302.7 Checking ONOS service - PASS (tick)
  • 302.8 Starting ONOS CLI sessions - PASS (tick)
  • 302.9 Checking ONOS nodes - PASS (tick)
  • 302.10 Checking ONOS applications - PASS (tick)
  • 302.11 Starting Mininet Topology - PASS (tick)
  • 302.12 Verify host IP address assignment in ONOS - PASS (tick)
  • 302.13 Verify IP address assignment from hosts - PASS (tick)
  • 302.14 Verify reachability of connected internal IPv6 hosts - FAIL (error)
    • Verify reachability of connected internal IPv6 hosts: Fail
  • 302.15 Stopping Mininet - PASS (tick)
    • Skipping the rest of this case.

Case 303: Test onos failures with IPv4 and IPv6 hosts - FAIL

  • 303.1 Apply cell to environment - PASS (tick)
  • 303.2 Uninstalling Atomix - PASS (tick)
  • 303.3 Uninstalling ONOS package - PASS (tick)
  • 303.4 Installing Atomix - PASS (tick)
  • 303.5 Installing ONOS package - PASS (tick)
  • 303.6 Set up ONOS secure SSH - PASS (tick)
  • 303.7 Checking ONOS service - PASS (tick)
  • 303.8 Starting ONOS CLI sessions - PASS (tick)
  • 303.9 Checking ONOS nodes - PASS (tick)
  • 303.10 Checking ONOS applications - PASS (tick)
  • 303.11 Starting Mininet Topology - PASS (tick)
  • 303.12 Verify host IP address assignment in ONOS - PASS (tick)
  • 303.13 Verify IP address assignment from hosts - PASS (tick)
  • 303.14 Verify reachability of connected internal IPv4 hosts - PASS (tick)
  • 303.15 Verify reachability of connected internal IPv6 hosts - FAIL (error)
    • Verify reachability of connected internal IPv6 hosts: Fail
  • 303.16 Stopping Mininet - PASS (tick)
    • Skipping the rest of this case.

Case 304: Test onos failures with IPv4 hosts including external hosts - PASS

  • 304.1 Apply cell to environment - PASS (tick)
  • 304.2 Uninstalling Atomix - PASS (tick)
  • 304.3 Uninstalling ONOS package - PASS (tick)
  • 304.4 Installing Atomix - PASS (tick)
  • 304.5 Installing ONOS package - PASS (tick)
  • 304.6 Set up ONOS secure SSH - PASS (tick)
  • 304.7 Checking ONOS service - PASS (tick)
  • 304.8 Starting ONOS CLI sessions - PASS (tick)
  • 304.9 Checking ONOS nodes - PASS (tick)
  • 304.10 Checking ONOS applications - PASS (tick)
  • 304.11 Starting Mininet Topology - PASS (tick)
  • 304.12 Verify host IP address assignment in ONOS - PASS (tick)
  • 304.13 Verify IP address assignment from hosts - PASS (tick)
  • 304.14 Verify reachability of connected internal IPv4 hosts - PASS (tick)
  • 304.15 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS (tick)
  • 304.16 Killing ONOS instances with index(es): [0] - PASS (tick)
  • 304.17 Check number of topology elements - PASS (tick)
  • 304.18 Verify host IP address assignment in ONOS - PASS (tick)
  • 304.19 Verify IP address assignment from hosts - PASS (tick)
  • 304.20 Verify reachability of connected internal IPv4 hosts - PASS (tick)
  • 304.21 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS (tick)
  • 304.22 Recovering ONOS instances with index(es): [0] - PASS (tick)
  • 304.23 Checking if ONOS CLI is ready - PASS (tick)
  • 304.24 Checking ONOS nodes - PASS (tick)
  • 304.25 Check number of topology elements - PASS (tick)
  • 304.26 Verify host IP address assignment in ONOS - PASS (tick)
  • 304.27 Verify IP address assignment from hosts - PASS (tick)
  • 304.28 Verify reachability of connected internal IPv4 hosts - PASS (tick)
  • 304.29 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS (tick)
  • 304.30 Killing ONOS instances with index(es): [1] - PASS (tick)
  • 304.31 Check number of topology elements - PASS (tick)
  • 304.32 Verify host IP address assignment in ONOS - PASS (tick)
  • 304.33 Verify IP address assignment from hosts - PASS (tick)
  • 304.34 Verify reachability of connected internal IPv4 hosts - PASS (tick)
  • 304.35 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS (tick)
  • 304.36 Recovering ONOS instances with index(es): [1] - PASS (tick)
  • 304.37 Checking if ONOS CLI is ready - PASS (tick)
  • 304.38 Checking ONOS nodes - PASS (tick)
  • 304.39 Check number of topology elements - PASS (tick)
  • 304.40 Verify host IP address assignment in ONOS - PASS (tick)
  • 304.41 Verify IP address assignment from hosts - PASS (tick)
  • 304.42 Verify reachability of connected internal IPv4 hosts - PASS (tick)
  • 304.43 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS (tick)
  • 304.44 Killing ONOS instances with index(es): [2] - PASS (tick)
  • 304.45 Check number of topology elements - PASS (tick)
  • 304.46 Verify host IP address assignment in ONOS - PASS (tick)
  • 304.47 Verify IP address assignment from hosts - PASS (tick)
  • 304.48 Verify reachability of connected internal IPv4 hosts - PASS (tick)
  • 304.49 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS (tick)
  • 304.50 Recovering ONOS instances with index(es): [2] - PASS (tick)
  • 304.51 Checking if ONOS CLI is ready - PASS (tick)
  • 304.52 Checking ONOS nodes - PASS (tick)
  • 304.53 Check number of topology elements - PASS (tick)
  • 304.54 Verify host IP address assignment in ONOS - PASS (tick)
  • 304.55 Verify IP address assignment from hosts - PASS (tick)
  • 304.56 Verify reachability of connected internal IPv4 hosts - PASS (tick)
  • 304.57 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS (tick)
  • 304.58 Stopping Mininet - PASS (tick)

Case 305: Test onos failures with IPv6 hosts including external hosts - FAIL

  • 305.1 Apply cell to environment - PASS (tick)
  • 305.2 Uninstalling Atomix - PASS (tick)
  • 305.3 Uninstalling ONOS package - PASS (tick)
  • 305.4 Installing Atomix - PASS (tick)
  • 305.5 Installing ONOS package - PASS (tick)
  • 305.6 Set up ONOS secure SSH - PASS (tick)
  • 305.7 Checking ONOS service - PASS (tick)
  • 305.8 Starting ONOS CLI sessions - PASS (tick)
  • 305.9 Checking ONOS nodes - PASS (tick)
  • 305.10 Checking ONOS applications - PASS (tick)
  • 305.11 Starting Mininet Topology - PASS (tick)
  • 305.12 Verify host IP address assignment in ONOS - PASS (tick)
  • 305.13 Verify IP address assignment from hosts - PASS (tick)
  • 305.14 Verify reachability of connected internal IPv6 hosts - FAIL (error)
    • Verify reachability of connected internal IPv6 hosts: Fail
  • 305.15 Stopping Mininet - PASS (tick)
    • Skipping the rest of this case.

Case 306: Test onos failures with IPv4 and IPv6 hosts including external hosts - FAIL

  • 306.1 Apply cell to environment - PASS (tick)
  • 306.2 Uninstalling Atomix - PASS (tick)
  • 306.3 Uninstalling ONOS package - PASS (tick)
  • 306.4 Installing Atomix - PASS (tick)
  • 306.5 Installing ONOS package - PASS (tick)
  • 306.6 Set up ONOS secure SSH - PASS (tick)
  • 306.7 Checking ONOS service - PASS (tick)
  • 306.8 Starting ONOS CLI sessions - PASS (tick)
  • 306.9 Checking ONOS nodes - PASS (tick)
  • 306.10 Checking ONOS applications - PASS (tick)
  • 306.11 Starting Mininet Topology - PASS (tick)
  • 306.12 Verify host IP address assignment in ONOS - PASS (tick)
  • 306.13 Verify IP address assignment from hosts - PASS (tick)
  • 306.14 Verify reachability of connected internal IPv4 hosts - PASS (tick)
  • 306.15 Verify reachability of connected internal IPv6 hosts - FAIL (error)
    • Verify reachability of connected internal IPv6 hosts: Fail
  • 306.16 Stopping Mininet - PASS (tick)
    • Skipping the rest of this case.

Case 307: Test onos failures with IPv4 hosts including external hosts configured with route-add command - PASS

  • 307.1 Apply cell to environment - PASS (tick)
  • 307.2 Uninstalling Atomix - PASS (tick)
  • 307.3 Uninstalling ONOS package - PASS (tick)
  • 307.4 Installing Atomix - PASS (tick)
  • 307.5 Installing ONOS package - PASS (tick)
  • 307.6 Set up ONOS secure SSH - PASS (tick)
  • 307.7 Checking ONOS service - PASS (tick)
  • 307.8 Starting ONOS CLI sessions - PASS (tick)
  • 307.9 Checking ONOS nodes - PASS (tick)
  • 307.10 Checking ONOS applications - PASS (tick)
  • 307.11 Starting Mininet Topology - PASS (tick)
  • 307.12 Verify host IP address assignment in ONOS - PASS (tick)
  • 307.13 Verify IP address assignment from hosts - PASS (tick)
  • 307.14 Verify reachability of connected internal IPv4 hosts - PASS (tick)
  • 307.15 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS (tick)
  • 307.16 Killing ONOS instances with index(es): [0] - PASS (tick)
  • 307.17 Check number of topology elements - PASS (tick)
  • 307.18 Verify host IP address assignment in ONOS - PASS (tick)
  • 307.19 Verify IP address assignment from hosts - PASS (tick)
  • 307.20 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS (tick)
  • 307.21 Recovering ONOS instances with index(es): [0] - PASS (tick)
  • 307.22 Checking if ONOS CLI is ready - PASS (tick)
  • 307.23 Checking ONOS nodes - PASS (tick)
  • 307.24 Check number of topology elements - PASS (tick)
  • 307.25 Verify host IP address assignment in ONOS - PASS (tick)
  • 307.26 Verify IP address assignment from hosts - PASS (tick)
  • 307.27 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS (tick)
  • 307.28 Killing ONOS instances with index(es): [1] - PASS (tick)
  • 307.29 Check number of topology elements - PASS (tick)
  • 307.30 Verify host IP address assignment in ONOS - PASS (tick)
  • 307.31 Verify IP address assignment from hosts - PASS (tick)
  • 307.32 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS (tick)
  • 307.33 Recovering ONOS instances with index(es): [1] - PASS (tick)
  • 307.34 Checking if ONOS CLI is ready - PASS (tick)
  • 307.35 Checking ONOS nodes - PASS (tick)
  • 307.36 Check number of topology elements - PASS (tick)
  • 307.37 Verify host IP address assignment in ONOS - PASS (tick)
  • 307.38 Verify IP address assignment from hosts - PASS (tick)
  • 307.39 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS (tick)
  • 307.40 Killing ONOS instances with index(es): [2] - PASS (tick)
  • 307.41 Check number of topology elements - PASS (tick)
  • 307.42 Verify host IP address assignment in ONOS - PASS (tick)
  • 307.43 Verify IP address assignment from hosts - PASS (tick)
  • 307.44 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS (tick)
  • 307.45 Recovering ONOS instances with index(es): [2] - PASS (tick)
  • 307.46 Checking if ONOS CLI is ready - PASS (tick)
  • 307.47 Checking ONOS nodes - PASS (tick)
  • 307.48 Check number of topology elements - PASS (tick)
  • 307.49 Verify host IP address assignment in ONOS - PASS (tick)
  • 307.50 Verify IP address assignment from hosts - PASS (tick)
  • 307.51 Verify reachability from connected internal IPv4 hosts to external IPv4 hosts - PASS (tick)
  • 307.52 Stopping Mininet - PASS (tick)

Case 308: Test onos failures with IPv6 hosts including external hosts configured with route-add command - FAIL

  • 308.1 Apply cell to environment - PASS (tick)
  • 308.2 Uninstalling Atomix - PASS (tick)
  • 308.3 Uninstalling ONOS package - PASS (tick)
  • 308.4 Installing Atomix - PASS (tick)
  • 308.5 Installing ONOS package - PASS (tick)
  • 308.6 Set up ONOS secure SSH - PASS (tick)
  • 308.7 Checking ONOS service - PASS (tick)
  • 308.8 Starting ONOS CLI sessions - PASS (tick)
  • 308.9 Checking ONOS nodes - PASS (tick)
  • 308.10 Checking ONOS applications - PASS (tick)
  • 308.11 Starting Mininet Topology - PASS (tick)
  • 308.12 Verify host IP address assignment in ONOS - PASS (tick)
  • 308.13 Verify IP address assignment from hosts - PASS (tick)
  • 308.14 Verify reachability of connected internal IPv6 hosts - FAIL (error)
    • Verify reachability of connected internal IPv6 hosts: Fail
  • 308.15 Stopping Mininet - PASS (tick)
    • Skipping the rest of this case.

Case 309: Test onos failures with IPv4 and IPv6 hosts including external hosts configured with route-add command - FAIL

  • 309.1 Apply cell to environment - PASS (tick)
  • 309.2 Uninstalling Atomix - PASS (tick)
  • 309.3 Uninstalling ONOS package - PASS (tick)
  • 309.4 Installing Atomix - PASS (tick)
  • 309.5 Installing ONOS package - PASS (tick)
  • 309.6 Set up ONOS secure SSH - PASS (tick)
  • 309.7 Checking ONOS service - PASS (tick)
  • 309.8 Starting ONOS CLI sessions - PASS (tick)
  • 309.9 Checking ONOS nodes - PASS (tick)
  • 309.10 Checking ONOS applications - PASS (tick)
  • 309.11 Starting Mininet Topology - PASS (tick)
  • 309.12 Verify host IP address assignment in ONOS - PASS (tick)
  • 309.13 Verify IP address assignment from hosts - PASS (tick)
  • 309.14 Verify reachability of connected internal IPv4 hosts - PASS (tick)
  • 309.15 Verify reachability of connected internal IPv6 hosts - FAIL (error)
    • Verify reachability of connected internal IPv6 hosts: Fail
  • 309.16 Stopping Mininet - PASS (tick)
    • Skipping the rest of this case.

...

    • Skipping the rest of this case.