- 53.1 Apply cell to environment - PASS
- 53.2 Uninstalling Atomix - PASS
- 53.3 Uninstalling ONOS package - PASS
- 53.4 Create Cluster Config - PASS
- 53.5 Installing Atomix via docker containers - PASS
- 53.6 Installing ONOS via docker containers - PASS
- 53.7 Set up ONOS secure SSH - PASS
- 53.8 Starting ONOS CLI sessions - PASS
- 53.9 Checking ONOS nodes - PASS
- 53.10 Checking ONOS applications - PASS
- 53.11 Set logging levels - PASS
- 53.12 Set ONOS configurations - PASS
- 53.13 Starting Mininet Topology - PASS
- 53.14 Configure switches in ONOS - PASS
- 53.15 Check whether the flow count is >= 104 - FAIL
- Flow count looks wrong; found 01, expecting at least 104
- 53.16 Check whether all flow status are ADDED - FAIL
- Flow status is wrong!
- 53.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE53_Before - PASS
- 53.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE53_Before - PASS
- 53.19 Check whether the flow count of device device:bmv2:leaf1 >= than 52 - FAIL
- Flow count looks wrong: 0
- 53.20 Check whether the flow count of device device:bmv2:leaf2 >= than 52 - FAIL
- Flow count looks wrong: 01
- 53.21 Check whether the flow count is >= 104 - FAIL
- Flow count looks wrong; found 01, expecting at least 104
- 53.22 Check whether all flow status are ADDED - FAIL
- Flow status is wrong!
- 53.23 Verify full connectivity for [u'h3', u'h4'] with tag CASE53_After - PASS
- 53.24 Verify full connectivity for [u'h1', u'h2'] with tag CASE53_After - PASS
- 53.25 Stopping Mininet - PASS
- 53.26 Copying karaf logs - PASS
...
- 63.1 Apply cell to environment - PASS
- 63.2 Uninstalling Atomix - PASS
- 63.3 Uninstalling ONOS package - PASS
- 63.4 Create Cluster Config - PASS
- 63.5 Installing Atomix via docker containers - PASS
- 63.6 Installing ONOS via docker containers - PASS
- 63.7 Set up ONOS secure SSH - PASS
- 63.8 Starting ONOS CLI sessions - PASS
- 63.9 Checking ONOS nodes - PASS
- 63.10 Checking ONOS applications - PASS
- 63.11 Set logging levels - PASS
- 63.12 Set ONOS configurations - PASS
- 63.13 Starting Mininet Topology - PASS
- 63.14 Configure switches in ONOS - PASS
- 63.15 Check whether the flow count is >= 104 - FAIL
- Flow count looks wrong; found 01, expecting at least 104
- 63.16 Check whether all flow status are ADDED - FAIL
- Flow status is wrong!
- 63.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE63_Before - PASS
- 63.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE63_Before - PASS
- 63.19 Check whether the flow count of device device:bmv2:leaf1 >= than 52 - FAIL
- Flow count looks wrong: 0
- 63.20 Check whether the flow count of device device:bmv2:leaf2 >= than 52 - FAIL
- Flow count looks wrong: 0
- 63.21 Check whether the flow count is >= 104 - FAIL
- Flow count looks wrong; found 01, expecting at least 104
- 63.22 Check whether all flow status are ADDED - FAIL
- Flow status is wrong!
- 63.23 Verify full connectivity for [u'h3', u'h4'] with tag CASE63_After - PASS
- 63.24 Verify full connectivity for [u'h1', u'h2'] with tag CASE63_After - PASS
- 63.25 Stopping Mininet - PASS
- 63.26 Copying karaf logs - PASS
...