Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric4/lastSuccessfulBuild/artifact/SRSwitchFailure_master_20-builds_graph.jpg", alt="SRSwitchFailure", style="width:525px;height:350px;border:0">

commit 31551b0c9116e3ff7507bd0f44c9d2220a753241 304b6644a1ac82c8929d1e04dc55ab69fffd65f4 (HEAD -] master, origin/master, origin/HEAD)
Author: Charles Chan Carmelo Cascone [charles@opennetworkingcarmelo@opennetworking.org]
AuthorDate: Tue Thu Jan 5 0228 17:0025:28 16 2021 +0000-0800
Commit: pierventre Carmelo Cascone [pier@opennetworkingcarmelo@opennetworking.org]
CommitDate: Wed Jan 13 16:52:16 2021 +0100
Lower LLDP log message when an unknown source is foundFri Feb 5 18:02:04 2021 +0000

Add digest to P4InfoBrowser
--
(cherry picked from commit 08be25533d09c3ba8023f4d34e07f4555d6013aa)

Case 1: Switch Failure test with 2x2 Leaf-spine and 1 Onos - PASS

...

  • 4.1 Apply cell to environment - PASS (tick)
  • 4.2 Uninstalling Atomix - PASS (tick)
  • 4.3 Uninstalling ONOS package - PASS (tick)
  • 4.4 Creating ONOS package - PASS (tick)
  • 4.5 Installing Atomix - PASS (tick)
  • 4.6 Installing ONOS package - PASS (tick)
  • 4.7 Set up ONOS secure SSH - PASS (tick)
  • 4.8 Checking ONOS service - PASS (tick)
  • 4.9 Starting ONOS CLI sessions - PASS (tick)
  • 4.10 Checking ONOS nodes - PASS (tick)
  • 4.11 Checking ONOS applications - PASS (tick)
  • 4.12 Set logging levels - PASS (tick)
  • 4.13 Set ONOS configurations - PASS (tick)
  • 4.14 Starting Mininet Topology - PASS (tick)
  • 4.15 Check whether the flow count is >= 116 - PASS (tick)
  • 4.16 Check whether all flow status are ADDED - PASS (tick)
  • 4.17 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE4 - PASS (tick)
  • 4.18 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE4 - PASS (tick)
  • 4.19 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE4 - PASS (tick)
  • 4.20 Kill ['spine101'] - PASS (tick)
  • 4.21 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE4_Failure - PASS (tick)
  • 4.22 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE4_Failure - PASS (tick)
  • 4.23 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE4_Failure - PASS (tick)
  • 4.24 Recovering ['spine101'] - PASS (tick)
  • 4.25 Check whether the flow count is >= 116 - PASS (tick)
  • 4.26 Check whether all flow status are ADDED - PASS (tick)
  • 4.27 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE4_Recovery - PASS (tick)
  • 4.28 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE4_Recovery - PASS (tick)
  • 4.29 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE4_Recovery - PASS (tick)
  • 4.30 Stopping Mininet - PASS (tick)
  • 4.31 Copying karaf logs - PASS (tick)

Case 5: Switch Failure test with 4x4 Leaf-spine and 3 Onos -

...

PASS

  • 5.1 Apply cell to environment - PASS (tick)
  • 5.2 Uninstalling Atomix - PASS (tick)
  • 5.3 Uninstalling ONOS package - PASS (tick)
  • 5.4 Creating ONOS package - PASS (tick)
  • 5.5 Installing Atomix - PASS (tick)
  • 5.6 Installing ONOS package - PASS (tick)
  • 5.7 Set up ONOS secure SSH - PASS (tick)
  • 5.8 Checking ONOS service - PASS (tick)
  • 5.9 Starting ONOS CLI sessions - PASS (tick)
  • 5.10 Checking ONOS nodes - PASS (tick)
  • 5.11 Checking ONOS applications - PASS (tick)
  • 5.12 Set logging levels - PASS (tick)
  • 5.13 Set ONOS configurations - PASS (tick)
  • 5.14 Starting Mininet Topology - PASS (tick)
  • 5.15 Check whether the flow count is >= 350 - PASS (tick)
  • 5.16 Check whether all flow status are ADDED - PASS (tick)
  • 5.17 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE5 - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 5.18 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE5 - PASS (tick)
  • 5.19 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE5 - PASS (tick)
  • 5.20 Kill ['spine101'] - PASS (tick)
  • 5.21 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE5_Failure - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 5.22 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE5_Failure - PASS (tick)
  • 5.23 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE5_Failure - PASS (tick)
  • 5.24 Recovering ['spine101'] - PASS (tick)
  • 5.25 Check whether the flow count is >= 350 - PASS (tick)
  • 5.26 Check whether all flow status are ADDED - PASS (tick)
  • 5.27 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE5_Recovery - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 5.28 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE5_Recovery - PASS (tick)
  • 5.29 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE5_Recovery - PASS (tick)
  • 5.30 Stopping Mininet - PASS (tick)
  • 5.31 Copying karaf logs - PASS (tick)