Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric4/lastSuccessfulBuild/artifact/SRDynamicConf-stratum_master_20-builds_graph.jpg", alt="SRDynamicConf-stratum", style="width:525px;height:350px;border:0">

commit 13b9017465d431d9ad4685dd408a426a151cdad5 8c553eb3170163b85612e6fb01aa5de7ac08c074 (HEAD -] master, origin/master, origin/HEAD)
Author: Thomas Vachuska Jian Li [tom@opennetworkingpyguni@gmail.orgcom]
AuthorDate: Tue Thu Mar 2 174 18:5948:58 39 2021 -0800+0900
Commit: Charles Chan Jian Li [charles@opennetworkingpyguni@gmail.orgcom]
CommitDate: Wed Thu Mar 3 214 10:0730:18 36 2021 +0000
[AETHER-1243] Adding more host icons and changing the default icon.
Fix: resolve a NPE caused by empty name list input in kubevirt CLI

Case 13: Changing port configuration from untagged 10 to tagged 10, with 2x2 leaf-spine topology and 3 ONOS instances - FAIL

...

  • 53.1 Apply cell to environment - PASS (tick)
  • 53.2 Uninstalling Atomix - PASS (tick)
  • 53.3 Uninstalling ONOS package - PASS (tick)
  • 53.4 Create Cluster Config - PASS (tick)
  • 53.5 Installing Atomix via docker containers - PASS (tick)
  • 53.6 Installing ONOS via docker containers - PASS (tick)
  • 53.7 Set up ONOS secure SSH - PASS (tick)
  • 53.8 Starting ONOS CLI sessions - PASS (tick)
  • 53.9 Checking ONOS nodes - PASS (tick)
  • 53.10 Checking ONOS applications - PASS (tick)
  • 53.11 Set logging levels - PASS (tick)
  • 53.12 Set ONOS configurations - PASS (tick)
  • 53.13 Starting Mininet Topology - PASS (tick)
  • 53.14 Configure switches in ONOS - PASS (tick)
  • 53.15 Check whether the flow count is >= 104 - FAIL (error)
    • Flow count looks wrong; found 10, expecting at least 104
  • 53.16 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 53.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE53_Before - PASS (tick)
  • 53.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE53_Before - PASS (tick)
  • 53.19 Check whether the flow count of device device:bmv2:leaf1 >= than 52 - FAIL (error)
    • Flow count looks wrong: 0
  • 53.20 Check whether the flow count of device device:bmv2:leaf2 >= than 52 - FAIL (error)
    • Flow count looks wrong: 10
  • 53.21 Check whether the flow count is >= 104 - FAIL (error)
    • Flow count looks wrong; found 10, expecting at least 104
  • 53.22 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 53.23 Verify full connectivity for [u'h3', u'h4'] with tag CASE53_After - PASS (tick)
  • 53.24 Verify full connectivity for [u'h1', u'h2'] with tag CASE53_After - PASS (tick)
  • 53.25 Stopping Mininet - PASS (tick)
  • 53.26 Copying karaf logs - PASS (tick)

...

  • 63.1 Apply cell to environment - PASS (tick)
  • 63.2 Uninstalling Atomix - PASS (tick)
  • 63.3 Uninstalling ONOS package - PASS (tick)
  • 63.4 Create Cluster Config - PASS (tick)
  • 63.5 Installing Atomix via docker containers - PASS (tick)
  • 63.6 Installing ONOS via docker containers - PASS (tick)
  • 63.7 Set up ONOS secure SSH - PASS (tick)
  • 63.8 Starting ONOS CLI sessions - PASS (tick)
  • 63.9 Checking ONOS nodes - PASS (tick)
  • 63.10 Checking ONOS applications - PASS (tick)
  • 63.11 Set logging levels - PASS (tick)
  • 63.12 Set ONOS configurations - PASS (tick)
  • 63.13 Starting Mininet Topology - PASS (tick)
  • 63.14 Configure switches in ONOS - PASS (tick)
  • 63.15 Check whether the flow count is >= 104 - FAIL (error)
    • Flow count looks wrong; found 10, expecting at least 104
  • 63.16 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 63.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE63_Before - PASS (tick)
  • 63.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE63_Before - PASS (tick)
  • 63.19 Check whether the flow count of device device:bmv2:leaf1 >= than 52 - FAIL (error)
    • Flow count looks wrong: 0
  • 63.20 Check whether the flow count of device device:bmv2:leaf2 >= than 52 - FAIL (error)
    • Flow count looks wrong: 0
  • 63.21 Check whether the flow count is >= 104 - FAIL (error)
    • Flow count looks wrong; found 10, expecting at least 104
  • 63.22 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 63.23 Verify full connectivity for [u'h3', u'h4'] with tag CASE63_After - PASS (tick)
  • 63.24 Verify full connectivity for [u'h1', u'h2'] with tag CASE63_After - PASS (tick)
  • 63.25 Stopping Mininet - PASS (tick)
  • 63.26 Copying karaf logs - PASS (tick)

...