Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric4/lastSuccessfulBuild/artifact/SRDynamicConf-stratum_master_20-builds_graph.jpg", alt="SRDynamicConf-stratum", style="width:525px;height:350px;border:0">

commit 8c553eb3170163b85612e6fb01aa5de7ac08c074 da7ec1571d66602b64b526e833ce09358ca63e3a (HEAD -] master, origin/master, origin/HEAD)
Author: Jian Li [pyguni@gmail.com]
AuthorDate: Thu Fri Mar 4 185 12:4821:39 50 2021 +0900
Commit: Jian Li [pyguni@gmail.com]
CommitDate: Thu Fri Mar 4 105 04:3000:36 18 2021 +0000

Fix: resolve a NPE caused by empty name list input in kubevirt CLIallow to obtains the added or removed internal on router event

Case 13: Changing port configuration from untagged 10 to tagged 10, with 2x2 leaf-spine topology and 3 ONOS instances - FAIL

...

  • 93.1 Apply cell to environment - PASS (tick)
  • 93.2 Uninstalling Atomix - PASS (tick)
  • 93.3 Uninstalling ONOS package - PASS (tick)
  • 93.4 Create Cluster Config - PASS (tick)
  • 93.5 Installing Atomix via docker containers - PASS (tick)
  • 93.6 Installing ONOS via docker containers - PASS (tick)
  • 93.7 Set up ONOS secure SSH - PASS (tick)
  • 93.8 Starting ONOS CLI sessions - PASS (tick)
  • 93.9 Checking ONOS nodes - PASS (tick)
  • 93.10 Checking ONOS applications - PASS (tick)
  • 93.11 Set logging levels - PASS (tick)
  • 93.12 Set ONOS configurations - PASS (tick)
  • 93.13 Starting Mininet Topology - PASS (tick)
  • 93.14 Configure switches in ONOS - PASS (tick)
  • 93.15 Check whether the flow count is >= 106 - FAIL (error)
    • Flow count looks wrong; found 0, expecting at least 106
  • 93.16 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 93.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE93_Before - PASS (tick)
  • 93.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE93_Before - PASS (tick)
  • 93.19 Check whether the flow count of device device:bmv2:leaf1 >= than 53 - FAIL (error)
    • Flow count looks wrong: 0
  • 93.20 Check whether the flow count of device device:bmv2:leaf2 >= than 53 - FAIL (error)
    • Flow count looks wrong: 0
  • 93.21 Check whether the flow count is >= 106 - FAIL (error)
    • Flow count looks wrong; found 0, expecting at least 106
  • 93.22 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 93.23 Verify full connectivity for [u'h3', u'h4'] with tag CASE93_After - PASS (tick)
  • 93.24 Verify full connectivity for [u'h1', u'h2'] with tag CASE93_After - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 93.25 Stopping Mininet - PASS (tick)
  • 93.26 Copying karaf logs - PASS (tick)

...