Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric4/lastSuccessfulBuild/artifact/SROnosFailure-stratum_master_20-builds_graph.jpg", alt="SROnosFailure-stratum", style="width:525px;height:350px;border:0">

commit e326c7218f2982378716f6496bf7fbed75ebbd47 d37181d7d105f276cf8ee8b5d464f62968f1e443 (HEAD -] master, origin/master, origin/HEAD)
Author: ersuneetsingh pierventre [erpier@opennetworking.suneetsingh@gmail.comorg]
AuthorDate: Thu Mon Mar 25 2129 22:1707:29 32 2021 -0300+0200
Commit: Carmelo Cascone [carmelo@opennetworkingPier Luigi Ventre [pier@opennetworking.org]
CommitDate: Tue Wed Mar 30 2031 06:0352:28 38 2021 +0000
Add action in pdrs tables to pass qid parameter

Enable read counters with table entries for stratum-tofino driver
--
(cherry picked from commit e4d1294c3006079f37bc493258df60a51698e338)

Case 1: ONOS Failure test with 2x2 Leaf-spine - FAIL

...

  • 1.1 Constructing test variables - PASS (tick)
  • 1.2 Apply cell to environment - PASS (tick)
  • 1.3 Uninstalling Atomix - PASS (tick)
  • 1.4 Uninstalling ONOS package - PASS (tick)
  • 1.5 Building ONOS Docker image - PASS (tick)
  • 1.6 Create Cluster Config - PASS (tick)
  • 1.7 Installing Atomix via docker containers - PASS (tick)
  • 1.8 Installing ONOS via docker containers - PASS (tick)
  • 1.9 Set up ONOS secure SSH - PASS (tick)
  • 1.10 Starting ONOS CLI sessions - PASS (tick)
  • 1.11 Checking ONOS nodes - PASS (tick)
  • 1.12 Checking ONOS applications - PASS (tick)
  • 1.13 Set logging levels - PASS (tick)
  • 1.14 Set ONOS configurations - PASS (tick)
  • 1.15 Starting Mininet Topology - PASS (tick)
  • 1.16 Configure switches in ONOS - PASS (tick)
  • 1.17 Check number of topology elements - PASS (tick)
  • 1.18 Check whether the flow count is >= 116 - FAIL (error)
    • Flow count looks wrong; found 0, expecting at least 116
  • 1.19 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 1.20 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 1.21 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.22 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.23 Killing ONOS instances with index(es): [0] - PASS (tick)
  • 1.24 Check number of topology elements - PASS (tick)
  • 1.25 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 1.26 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.27 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.28 Recovering ONOS instances with index(es): [0] - PASS (tick)
  • 1.29 Checking if ONOS CLI is ready - PASS (tick)
  • 1.30 Checking ONOS nodes - PASS (tick)
  • 1.31 Check number of topology elements - PASS (tick)
  • 1.32 Check whether the flow count is >= 116 - FAIL (error)
    • Flow count looks wrong; found 0, expecting at least 116
  • 1.33 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 1.34 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_Recovery - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 1.35 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_Recovery - FAIL (error)
    • IP connectivity failed
  • 1.36 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_Recovery - FAIL (error)
    • IP connectivity failed
  • 1.37 Check number of topology elements - PASS (tick)
  • 1.38 Stopping Mininet - PASS (tick)
  • 1.39 Copying karaf logs - PASS (tick)

...