Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Published from Jenkins build: https://jenkins.onosproject.org/job/FUNC-pipeline-master/1188/

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-VM/lastSuccessfulBuild/artifact/FUNCnetCfg_master_20-builds_graph.jpg", alt="FUNCnetCfg", style="width:525px;height:350px;border:0">

commit d1cc1a371fe0bc32d2e020f60edfe4945b5f80ac 7a888e878e734edea3342ad374212c44ba9095df (HEAD -] master, origin/master, origin/HEAD)
Author: Andrea Campanella Charles Chan [andrea@opennetworkingrascov@gmail.orgcom]
AuthorDate: Wed Mar 21 1016:0857:55 47 2018 -0700
Commit: Andrea Campanella Charles Chan [andrea@opennetworkingrascov@gmail.orgcom]
CommitDate: Wed Thu Mar 21 2122 14:0142:22 18 2018 +0000
Adding complete path to failed traces
--
(cherry picked from commit fec00e55291e26984d4af6a4030e99844598fd36)-0700

Move all event handler to a different executor

Case 1: Pull onos branch and build onos on Teststation. - PASS

...

Case 20: Add Network configurations to the cluster - FAIL

Add Network Configurations for devices not discovered yet. One device is allowed, the other disallowed.

  • 20.1 Add Net Cfg for switch1 - PASS (tick)
  • 20.2 Add Net Cfg for switch3 - PASS (tick)
  • 20.3 Check net config - FAIL (error)
    • Check Net Cfg failed. Check above messages.

Case 11: Start Mininet topology with OF 1.3 switches - PASS

Start mininet topology with OF 1.3 switches to test intents, exits out if topology did not start correctly

  • 11.1 Starting Mininet topology with OF 1.3 switches - PASS (tick)

Case 27: Posting network configurations to the top level web resource - PASS

  • 27.1 Get json object from Net Cfg - No Result (warning)
  • 27.2 Posting json object to Net Cfg - No Result (warning)
  • 27.3 Compare device with ONOS - No Result (warning)
  • 27.4 Check net config - PASS (tick)
  • 27.5 ONOS should only show devices S1, S2, S4, S5 and S6 - PASS (tick)
  • 27.6 Modify json object so S6 is disallowed - PASS (tick)

Case 26: Check to see if the pre-startup configurations were set, then remove their allowed status - PASS

  • 26.1 Checking configurations for Switches 5 and 6 - No Result (warning)
  • 26.2 ONOS should only show devices S1, S2, S4, and S5 - PASS (tick)
  • 26.3 Removing allowed status from Switches 5 and 6 - No Result (warning)

Case 21: Check Devices After they initially connect to ONOS - PASS

  • 21.1 Check net config - PASS (tick)
  • 21.2 ONOS should only show devices S1, S2, and S4 - PASS (tick)
  • 21.3 Check device annotations - PASS (tick)

Case 22: Add Network configurations for connected devices to the cluster - PASS

Add Network Configurations for discovered devices. One device is allowed, the other disallowed.

  • 22.1 Add Net Cfg for switch2 - PASS (tick)
  • 22.2 Add Net Cfg for switch4 - PASS (tick)
  • 22.3 Check net config - PASS (tick)

Case 23: Check Devices after all configurations are set - PASS

  • 23.1 Check net config - PASS (tick)
  • 23.2 ONOS should only show devices S1 and S2 - PASS (tick)
  • 23.3 Check device annotations - PASS (tick)

Case 24: Testing removal of configurations - PASS

...