Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
HTML |
---|
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric/lastSuccessfulBuild/artifact/SRDynamicConf_onos-1.12_20-builds_graph.jpg", alt="SRDynamicConf", style="width:525px;height:350px;border:0"> |
commit 95da6491db769b90120eb2638c76cca2ac418289 1cef740e07b21f8b9bfaada5e1dd057de6345e79 (HEAD -] onos-1.12, origin/onos-1.12)
Author: Andrea Campanella Devin Lim [andrea@opennetworkingdevin@opennetworking.org]
AuthorDate: Mon Wed Mar 26 1028 18:3919:22 57 2018 -0700
Commit: Andrea Campanella Devin Lim [andrea@opennetworkingdevin@opennetworking.org]
CommitDate: Mon Wed Mar 26 1128 18:3045:31 24 2018 -0700
T3 Fixes:
[ONOS-7565] Flow rules error while rerouting intents with Flow Objectives 1.12
Case 13: Changing port configuration from untagged 10 to tagged 10, with 2x2 leaf-spine topology and 3 ONOS instances - PASS
...
- 33.1 Apply cell to environment - PASS
- 33.2 Uninstalling ONOS package - PASS
- 33.3 Installing ONOS package - PASS
- 33.4 Set up ONOS secure SSH - PASS
- 33.5 Checking ONOS service - PASS
- 33.6 Starting ONOS CLI sessions - PASS
- 33.7 Starting Mininet Topology - PASS
- 33.8 Check whether the flow count is bigger than 104 - PASS
- 33.9 Check whether all flow status are ADDED - PASS
- 33.10 Verify full connectivity for [u'h3', u'h4'] with tag CASE33_Before - PASS
- 33.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE33_Before - PASS
- 33.12 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 33.13 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 33.14 Check whether the flow count is bigger than 104 - PASS
- 33.15 Check whether all flow status are ADDED - FAIL Flow status is wrong!
- PASS
- 33.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE33_After - PASS
- 33.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE33_After - FAIL
- IP connectivity failed
- 33.18 Stopping Mininet - PASS
- 33.19 Copying karaf logs - PASS
...
- 63.1 Apply cell to environment - PASS
- 63.2 Uninstalling ONOS package - PASS
- 63.3 Installing ONOS package - PASS
- 63.4 Set up ONOS secure SSH - PASS
- 63.5 Checking ONOS service - PASS
- 63.6 Starting ONOS CLI sessions - PASS
- 63.7 Starting Mininet Topology - PASS
- 63.8 Check whether the flow count is bigger than 104 - PASS
- 63.9 Check whether all flow status are ADDED - PASS
- 63.10 Verify full connectivity for [u'h3', u'h4'] with tag CASE63_Before - PASS
- 63.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE63_Before - PASS
- 63.12 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 63.13 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 63.14 Check whether the flow count is bigger than 104 - PASS
- 63.15 Check whether all flow status are ADDED - FAIL
- Flow status is wrong!
- 63.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE63_After - PASS
- 63.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE63_After - FAIL IP connectivity failed
- PASS
- 63.18 Stopping Mininet - PASS
- 63.19 Copying karaf logs - PASS
...
- 163.1 Apply cell to environment - PASS
- 163.2 Uninstalling ONOS package - PASS
- 163.3 Installing ONOS package - PASS
- 163.4 Set up ONOS secure SSH - PASS
- 163.5 Checking ONOS service - PASS
- 163.6 Starting ONOS CLI sessions - PASS
- 163.7 Starting Mininet Topology - PASS
- 163.8 Check whether the flow count is bigger than 106 - PASS
- 163.9 Check whether all flow status are ADDED - PASS
- 163.10 Verify full connectivity for [u'h3', u'h4'] with tag CASE163_Before - PASS
- 163.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE163_Before - PASS
- 163.12 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 163.13 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 163.14 Check whether the flow count is bigger than 106 - PASS
- 163.15 Check whether all flow status are ADDED - PASS
- 163.16 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE163_After - PASS
- 163.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE163_After - PASS
- 163.18 Stopping Mininet - PASS
- 163.19 Copying karaf logs - PASS
Case 173: Changing port configuration from tagged 20 to tagged 120, with 2x2 leaf-spine topology and 3 ONOS instances -
...
FAIL
- 173.1 Apply cell to environment - PASS
- 173.2 Uninstalling ONOS package - PASS
- 173.3 Installing ONOS package - PASS
- 173.4 Set up ONOS secure SSH - PASS
- 173.5 Checking ONOS service - PASS
- 173.6 Starting ONOS CLI sessions - PASS
- 173.7 Starting Mininet Topology - PASS
- 173.8 Check whether the flow count is bigger than 106 - PASS
- 173.9 Check whether all flow status are ADDED - PASS
- 173.10 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE173_Before - PASS
- 173.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE173_Before - PASS
- 173.12 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 173.13 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 173.14 Check whether the flow count is bigger than 106 - PASS
- 173.15 Check whether all flow status are ADDED - PASS FAIL
- Flow status is wrong!
- 173.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE173_After - PASS
- 173.17 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE173_After - PASS
- 173.18 Stopping Mininet - PASS