Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Published from Jenkins build: https://jenkins.onosproject.org/job/SR-pipeline-1.13/203/

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric2/lastSuccessfulBuild/artifact/SRClusterRestart_onos-1.13_20-builds_graph.jpg", alt="SRClusterRestart", style="width:525px;height:350px;border:0">

commit ed4f9e2214d35ec730818c8a58be210ac63068b3 8d6edf3216f7bce64b92852ce8e4efd2be46dcd9 (HEAD -] onos-1.13, origin/onos-1.13)
Author: Charles Chan [rascov@gmailsnehaprem [sneha.prem@infosys.com]
AuthorDate: Fri Oct 26 15:54:32 2018 -0700Thu Nov 1 01:02:21 2018 -0400
Commit: Charles Chan [charles@opennetworking.org]
CommitDate: Fri Oct 26 22:56:42 Nov 2 06:12:21 2018 +0000
Update onos-diagnostics to include the latest SR commands

route-remove cli command with source type addition
--
(cherry picked from commit 7828d01ca571190c1c3ba526dd24ef6e7399c79c)

Case 1: Cluster Restart test with 2x2 Leaf-spine - FAIL

...

  • 2.1 Apply cell to environment - PASS (tick)
  • 2.2 Uninstalling ONOS package - PASS (tick)
  • 2.3 Creating ONOS package - PASS (tick)
  • 2.4 Installing ONOS package - PASS (tick)
  • 2.5 Set up ONOS secure SSH - PASS (tick)
  • 2.6 Checking ONOS service - PASS (tick)
  • 2.7 Starting ONOS CLI sessions - PASS (tick)
  • 2.8 Checking ONOS nodes - PASS (tick)
  • 2.9 Checking ONOS applications - PASS (tick)
  • 2.10 Starting Mininet Topology - PASS (tick)
  • 2.11 Check whether the flow count is bigger than 350 - PASS (tick)
  • 2.12 Check whether all flow status are ADDED - PASS (tick)
  • 2.13 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.14 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2 - PASS (tick)
  • 2.15 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2 - PASS (tick)
  • 2.16 Killing ONOS instances with index(es): [0, 1, 2] - PASS (tick)
  • 2.17 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2_Failure - FAIL (error)
    • IP connectivity failed
  • 2.18 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_Failure - PASS (tick)
  • 2.19 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_Failure - PASS (tick)
  • 2.20 Recovering ONOS instances with index(es): [0, 1, 2] - PASS (tick)
  • 2.21 Checking if ONOS CLI is ready - PASS (tick)
  • 2.22 Checking if ONOS CLI is ready - PASS (tick)
  • 2.23 Checking if ONOS CLI is ready - PASS (tick)
  • 2.24 Checking ONOS nodes - PASS (tick)
  • 2.25 Check number of topology elements - PASS (tick)
  • 2.26 Check whether the flow count is bigger than 350 - PASS (tick)
  • 2.27 Check whether all flow status are ADDED - PASS (tick)
  • 2.28 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2_Failure - FAIL (error)
    • IP connectivity failed
  • 2.29 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_Failure - PASS (tick)
  • 2.30 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_Failure - PASS (tick)
  • 2.31 Stopping Mininet - PASS (tick)
  • 2.32 Copying karaf logs - PASS (tick)

Case 3: Cluster Restart test with single switch -

...

FAIL

  • 3.1 Apply cell to environment - PASS (tick)
  • 3.2 Uninstalling ONOS package - PASS (tick)
  • 3.3 Creating ONOS package - PASS (tick)
  • 3.4 Installing ONOS package - PASS (tick)
  • 3.5 Set up ONOS secure SSH - PASS (tick)
  • 3.6 Checking ONOS service - PASS (tick)
  • 3.7 Starting ONOS CLI sessions - PASS (tick)
  • 3.8 Checking ONOS nodes - PASS (tick)
  • 3.9 Checking ONOS applications - PASS (tick)
  • 3.10 Starting Mininet Topology - PASS (tick)
  • 3.11 Check whether the flow count is bigger than 15 - PASS (tick)
  • 3.12 Check whether all flow status are ADDED - PASS (tick)
  • 3.13 Verify full connectivity for [u'h1', u'h2'] with tag CASE3 - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 3.14 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3 - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 3.15 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3 - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 3.16 Killing ONOS instances with index(es): [0, 1, 2] - PASS (tick)
  • 3.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE3_Failure - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 3.18 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3_Failure - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 3.19 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3_Failure - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 3.20 Recovering ONOS instances with index(es): [0, 1, 2] - PASS (tick)
  • 3.21 Checking if ONOS CLI is ready - PASS (tick)
  • 3.22 Checking if ONOS CLI is ready - PASS (tick)
  • 3.23 Checking if ONOS CLI is ready - PASS (tick)
  • 3.24 Checking ONOS nodes - PASS (tick)
  • 3.25 Check number of topology elements - PASS (tick)
  • 3.26 Check whether the flow count is bigger than 15 - PASS (tick)
  • 3.27 Check whether all flow status are ADDED - PASS (tick)
  • 3.28 Verify full connectivity for [u'h1', u'h2'] with tag CASE3_Failure - PASS (tick)
  • 3.29 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3_Failure - PASS (tick)
  • 3.30 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3_Failure - PASS (tick)
  • 3.31 Stopping Mininet - PASS (tick)
  • 3.32 Copying karaf logs - PASS (tick)