Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Published from Jenkins build: https://jenkins.onosproject.org/job/SR-pipeline-1.13/183/

...

  • 23.1 Apply cell to environment - PASS (tick)
  • 23.2 Uninstalling ONOS package - PASS (tick)
  • 23.3 Installing ONOS package - PASS (tick)
  • 23.4 Set up ONOS secure SSH - PASS (tick)
  • 23.5 Checking ONOS service - PASS (tick)
  • 23.6 Starting ONOS CLI sessions - PASS (tick)
  • 23.7 Checking ONOS nodes - PASS (tick)
  • 23.8 Checking ONOS applications - PASS (tick)
  • 23.9 Starting Mininet Topology - PASS (tick)
  • 23.10 Check whether the flow count is bigger than 106 - PASS (tick)
  • 23.11 Check whether all flow status are ADDED - PASS (tick)
  • 23.12 Verify full connectivity for [u'h3', u'h4'] with tag CASE23_Before - PASS (tick)
  • 23.13 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_Before - PASS (tick)
  • 23.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 23.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 23.16 Check whether the flow count is bigger than 106 - PASS (tick)
  • 23.17 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 23.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_After - PASS (tick)
  • 23.19 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE23_After - PASS (tick)
  • 23.20 Stopping Mininet - PASS (tick)
  • 23.21 Copying karaf logs - PASS (tick)

Case 33: Changing port configuration from untagged 10 to untagged 110, with 2x2 leaf-spine topology and 3 ONOS instances -

...

PASS

  • 33.1 Apply cell to environment - PASS (tick)
  • 33.2 Uninstalling ONOS package - PASS (tick)
  • 33.3 Installing ONOS package - PASS (tick)
  • 33.4 Set up ONOS secure SSH - PASS (tick)
  • 33.5 Checking ONOS service - PASS (tick)
  • 33.6 Starting ONOS CLI sessions - PASS (tick)
  • 33.7 Checking ONOS nodes - PASS (tick)
  • 33.8 Checking ONOS applications - PASS (tick)
  • 33.9 Starting Mininet Topology - PASS (tick)
  • 33.10 Check whether the flow count is bigger than 104 - PASS (tick)
  • 33.11 Check whether all flow status are ADDED - PASS (tick)
  • 33.12 Verify full connectivity for [u'h3', u'h4'] with tag CASE33_Before - PASS (tick)
  • 33.13 Verify full connectivity for [u'h1', u'h2'] with tag CASE33_Before - PASS (tick)
  • 33.14 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 33.15 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 33.16 Check whether the flow count is bigger than 104 - PASS (tick)
  • 33.17 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • PASS (tick)
  • 33.18 Verify full connectivity for [u'h3', u'h4'] with tag CASE33_After - PASS (tick)
  • 33.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE33_After - PASS (tick)
  • 33.20 Stopping Mininet - PASS (tick)
  • 33.21 Copying karaf logs - PASS (tick)

...

  • 53.1 Apply cell to environment - PASS (tick)
  • 53.2 Uninstalling ONOS package - PASS (tick)
  • 53.3 Installing ONOS package - PASS (tick)
  • 53.4 Set up ONOS secure SSH - PASS (tick)
  • 53.5 Checking ONOS service - PASS (tick)
  • 53.6 Starting ONOS CLI sessions - PASS (tick)
  • 53.7 Checking ONOS nodes - PASS (tick)
  • 53.8 Checking ONOS applications - PASS (tick)
  • 53.9 Starting Mininet Topology - PASS (tick)
  • 53.10 Check whether the flow count is bigger than 104 - PASS (tick)
  • 53.11 Check whether all flow status are ADDED - PASS (tick)
  • 53.12 Verify full connectivity for [u'h3', u'h4'] with tag CASE53_Before - PASS (tick)
  • 53.13 Verify full connectivity for [u'h1', u'h2'] with tag CASE53_Before - PASS (tick)
  • 53.14 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 53.15 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 53.16 Check whether the flow count is bigger than 104 - PASS (tick)
  • 53.17 Check whether all flow status are ADDED - PASS (tick)
  • 53.18 Verify full connectivity for [u'h3', u'h4'] with tag CASE53_After - PASS (tick)
  • 53.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE53_After - PASS (tick)
  • 53.20 Stopping Mininet - PASS (tick)
  • 53.21 Copying karaf logs - PASS (tick)

Case 63: Changing port configuration from untagged 10 to tagged 120 with native 110, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 63.1 Apply cell to environment - PASS (tick)
  • 63.2 Uninstalling ONOS package - PASS (tick)
  • 63.3 Installing ONOS package - PASS (tick)
  • 63.4 Set up ONOS secure SSH - PASS (tick)
  • 63.5 Checking ONOS service - PASS (tick)
  • 63.6 Starting ONOS CLI sessions - PASS (tick)
  • 63.7 Checking ONOS nodes - PASS (tick)
  • 63.8 Checking ONOS applications - PASS (tick)
  • 63.9 Starting Mininet Topology - PASS (tick)
  • 63.10 Check whether the flow count is bigger than 104 - PASS (tick)
  • 63.11 Check whether all flow status are ADDED - PASS (tick)
  • 63.12 Verify full connectivity for [u'h3', u'h4'] with tag CASE63_Before - PASS (tick)
  • 63.13 Verify full connectivity for [u'h1', u'h2'] with tag CASE63_Before - PASS (tick)
  • 63.14 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 63.15 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 63.16 Check whether the flow count is bigger than 104 - PASS (tick)
  • 63.17 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 63.18 Verify full connectivity for [u'h3', u'h4'] with tag CASE63_After - PASS (tick)
  • 63.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE63_After - PASS (tick)
  • 63.20 Stopping Mininet - PASS (tick)
  • 63.21 Copying karaf logs - PASS (tick)

...

  • 103.1 Apply cell to environment - PASS (tick)
  • 103.2 Uninstalling ONOS package - PASS (tick)
  • 103.3 Installing ONOS package - PASS (tick)
  • 103.4 Set up ONOS secure SSH - PASS (tick)
  • 103.5 Checking ONOS service - PASS (tick)
  • 103.6 Starting ONOS CLI sessions - PASS (tick)
  • 103.7 Checking ONOS nodes - PASS (tick)
  • 103.8 Checking ONOS applications - PASS (tick)
  • 103.9 Starting Mininet Topology - PASS (tick)
  • 103.10 Check whether the flow count is bigger than 104 - PASS (tick)
  • 103.11 Check whether all flow status are ADDED - PASS (tick)
  • 103.12 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE103_Before - PASS (tick)
  • 103.13 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 103.14 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 103.15 Check whether the flow count is bigger than 104 - PASS (tick)
  • 103.16 Check whether all flow status are ADDED - PASS (tick)
  • 103.17 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE103_After - PASS (tick)
  • 103.18 Stopping Mininet - PASS (tick)
  • 103.19 Copying karaf logs - PASS (tick)

Case 113: Changing port configuration from tagged 20 and native 10 to tagged 20, with 2x2 leaf-spine topology and 3 ONOS instances -

...

PASS

  • 113.1 Apply cell to environment - PASS (tick)
  • 113.2 Uninstalling ONOS package - PASS (tick)
  • 113.3 Installing ONOS package - PASS (tick)
  • 113.4 Set up ONOS secure SSH - PASS (tick)
  • 113.5 Checking ONOS service - PASS (tick)
  • 113.6 Starting ONOS CLI sessions - PASS (tick)
  • 113.7 Checking ONOS nodes - PASS (tick)
  • 113.8 Checking ONOS applications - PASS (tick)
  • 113.9 Starting Mininet Topology - PASS (tick)
  • 113.10 Check whether the flow count is bigger than 104 - PASS (tick)
  • 113.11 Check whether all flow status are ADDED - PASS (tick)
  • 113.12 Verify full connectivity for [u'h3', u'h4'] with tag CASE113_Before - PASS (tick)
  • 113.13 Verify full connectivity for [u'h1', u'h2'] with tag CASE113_Before - PASS (tick)
  • 113.14 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 113.15 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 113.16 Check whether the flow count is bigger than 104 - PASS (tick)
  • 113.17 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • PASS (tick)
  • 113.18 Verify full connectivity for [u'h3', u'h4'] with tag CASE113_After - PASS (tick)
  • 113.19 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE113_After - PASS (tick)
  • 113.20 Stopping Mininet - PASS (tick)
  • 113.21 Copying karaf logs - PASS (tick)

...

  • 133.1 Apply cell to environment - PASS (tick)
  • 133.2 Uninstalling ONOS package - PASS (tick)
  • 133.3 Installing ONOS package - PASS (tick)
  • 133.4 Set up ONOS secure SSH - PASS (tick)
  • 133.5 Checking ONOS service - PASS (tick)
  • 133.6 Starting ONOS CLI sessions - PASS (tick)
  • 133.7 Checking ONOS nodes - PASS (tick)
  • 133.8 Checking ONOS applications - PASS (tick)
  • 133.9 Starting Mininet Topology - PASS (tick)
  • 133.10 Check whether the flow count is bigger than 104 - PASS (tick)
  • 133.11 Check whether all flow status are ADDED - PASS (tick)
  • 133.12 Verify full connectivity for [u'h3', u'h4'] with tag CASE133_Before - PASS (tick)
  • 133.13 Verify full connectivity for [u'h1', u'h2'] with tag CASE133_Before - PASS (tick)
  • 133.14 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 133.15 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 133.16 Check whether the flow count is bigger than 104 - PASS (tick)
  • 133.17 Check whether all flow status are ADDED - PASS (tick)
  • 133.18 Verify full connectivity for [u'h3', u'h4'] with tag CASE133_After - PASS (tick)
  • 133.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE133_After - PASS (tick)
  • 133.20 Stopping Mininet - PASS (tick)
  • 133.21 Copying karaf logs - PASS (tick)

Case 143: Changing port configuration from untagged 10 to tagged 20, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 143.1 Apply cell to environment - PASS (tick)
  • 143.2 Uninstalling ONOS package - PASS (tick)
  • 143.3 Installing ONOS package - PASS (tick)
  • 143.4 Set up ONOS secure SSH - PASS (tick)
  • 143.5 Checking ONOS service - PASS (tick)
  • 143.6 Starting ONOS CLI sessions - PASS (tick)
  • 143.7 Checking ONOS nodes - PASS (tick)
  • 143.8 Checking ONOS applications - PASS (tick)
  • 143.9 Starting Mininet Topology - PASS (tick)
  • 143.10 Check whether the flow count is bigger than 106 - PASS (tick)
  • 143.11 Check whether all flow status are ADDED - PASS (tick)
  • 143.12 Verify full connectivity for [u'h3', u'h4'] with tag CASE143_Before - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 143.13 Verify full connectivity for [u'h1', u'h2'] with tag CASE143_Before - PASS (tick)
  • 143.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 143.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 143.16 Check whether the flow count is bigger than 106 - PASS (tick)
  • 143.17 Check whether all flow status are ADDED - PASS (tick)
  • 143.18 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE143_After - PASS (tick)
  • 143.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE143_After - PASS (tick)
  • 143.20 Stopping Mininet - PASS (tick)
  • 143.21 Copying karaf logs - PASS (tick)

...

  • 173.1 Apply cell to environment - PASS (tick)
  • 173.2 Uninstalling ONOS package - PASS (tick)
  • 173.3 Installing ONOS package - PASS (tick)
  • 173.4 Set up ONOS secure SSH - PASS (tick)
  • 173.5 Checking ONOS service - PASS (tick)
  • 173.6 Starting ONOS CLI sessions - PASS (tick)
  • 173.7 Checking ONOS nodes - PASS (tick)
  • 173.8 Checking ONOS applications - PASS (tick)
  • 173.9 Starting Mininet Topology - PASS (tick)
  • 173.10 Check whether the flow count is bigger than 106 - PASS (tick)
  • 173.11 Check whether all flow status are ADDED - PASS (tick)
  • 173.12 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE173_Before - PASS (tick)
  • 173.13 Verify full connectivity for [u'h1', u'h2'] with tag CASE173_Before - PASS (tick)
  • 173.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 173.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 173.16 Check whether the flow count is bigger than 106 - PASS (tick)
  • 173.17 Check whether all flow status are ADDED - PASS (tick)
  • 173.18 Verify full connectivity for [u'h3', u'h4'] with tag CASE173_After - PASS (tick)
  • 173.19 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE173_After - PASS (tick)
  • 173.20 Stopping Mininet - PASS (tick)
  • 173.21 Copying karaf logs - PASS (tick)

Case 183: Changing port configuration from tagged 20 to tagged 20 and native 10, with 2x2 leaf-spine topology and 3 ONOS instances -

...

PASS

  • 183.1 Apply cell to environment - PASS (tick)
  • 183.2 Uninstalling ONOS package - PASS (tick)
  • 183.3 Installing ONOS package - PASS (tick)
  • 183.4 Set up ONOS secure SSH - PASS (tick)
  • 183.5 Checking ONOS service - PASS (tick)
  • 183.6 Starting ONOS CLI sessions - PASS (tick)
  • 183.7 Checking ONOS nodes - PASS (tick)
  • 183.8 Checking ONOS applications - PASS (tick)
  • 183.9 Starting Mininet Topology - PASS (tick)
  • 183.10 Check whether the flow count is bigger than 106 - FAIL (error)
    • Flow count looks wrong: False
  • PASS (tick)
  • 183.11 Check whether all flow status are ADDED - PASS (tick)
  • 183.12 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE183_Before - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 183.13 Verify full connectivity for [u'h1', u'h2'] with tag CASE183_Before - PASS (tick)
  • 183.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - FAIL (error)
  • Flow count looks wrong.
  • PASS (tick)
  • 183.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - FAIL (error)
  • Flow count looks wrong.
  • PASS (tick)
  • 183.16 Check whether the flow count is bigger than 106 - FAIL (error)
    • Flow count looks wrong: False
  • PASS (tick)
  • 183.17 Check whether all flow status are ADDED - PASS (tick)
  • 183.18 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE183_After - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 183.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE183_After - PASS (tick)
  • 183.20 Stopping Mininet - PASS (tick)
  • 183.21 Copying karaf logs - PASS (tick)

...

  • 193.1 Apply cell to environment - PASS (tick)
  • 193.2 Uninstalling ONOS package - PASS (tick)
  • 193.3 Installing ONOS package - PASS (tick)
  • 193.4 Set up ONOS secure SSH - PASS (tick)
  • 193.5 Checking ONOS service - PASS (tick)
  • 193.6 Starting ONOS CLI sessions - PASS (tick)
  • 193.7 Checking ONOS nodes - PASS (tick)
  • 193.8 Checking ONOS applications - PASS (tick)
  • 193.9 Starting Mininet Topology - PASS (tick)
  • 193.10 Check whether the flow count is bigger than 106 - PASS (tick)
  • 193.11 Check whether all flow status are ADDED - PASS (tick)
  • 193.12 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE193_Before - PASS (tick)
  • 193.13 Verify full connectivity for [u'h1', u'h2'] with tag CASE193_Before - PASS (tick)
  • 193.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 193.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 193.16 Check whether the flow count is bigger than 106 - PASS (tick)
  • 193.17 Check whether all flow status are ADDED - PASS (tick)
  • 193.18 Verify full connectivity for [u'h3', u'h4'] with tag CASE193_After - PASS (tick)
  • 193.19 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE193_After - PASS (tick)
  • 193.20 Stopping Mininet - PASS (tick)
  • 193.21 Copying karaf logs - PASS (tick)

Case 203: Changing port configuration from tagged 20 and native 10 to tagged 20, with 2x2 leaf-spine topology and 3 ONOS instances -

...

PASS

  • 203.1 Apply cell to environment - PASS (tick)
  • 203.2 Uninstalling ONOS package - PASS (tick)
  • 203.3 Installing ONOS package - PASS (tick)
  • 203.4 Set up ONOS secure SSH - PASS (tick)
  • 203.5 Checking ONOS service - PASS (tick)
  • 203.6 Starting ONOS CLI sessions - PASS (tick)
  • 203.7 Checking ONOS nodes - PASS (tick)
  • 203.8 Checking ONOS applications - PASS (tick)
  • 203.9 Starting Mininet Topology - PASS (tick)
  • 203.10 Check whether the flow count is bigger than 106 - FAIL (error)
  • Flow count looks wrong: False
  • PASS (tick)
  • 203.11 Check whether all flow status are ADDED - PASS (tick)
  • 203.12 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE203_Before - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 203.13 Verify full connectivity for [u'h1', u'h2'] with tag CASE203_Before - PASS (tick)
  • 203.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - FAIL (error)
  • Flow count looks wrong.
  • PASS (tick)
  • 203.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - FAIL (error)
    • Flow count looks wrong.
  • PASS (tick)
  • 203.16 Check whether the flow count is bigger than 106 - FAIL (error)
    • Flow count looks wrong: False
  • PASS (tick)
  • 203.17 Check whether all flow status are ADDED - PASS (tick)
  • 203.18 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE203_After - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 203.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE203_After - PASS (tick)
  • 203.20 Stopping Mininet - PASS (tick)
  • 203.21 Copying karaf logs - PASS (tick)

...

  • 233.1 Apply cell to environment - PASS (tick)
  • 233.2 Uninstalling ONOS package - PASS (tick)
  • 233.3 Installing ONOS package - PASS (tick)
  • 233.4 Set up ONOS secure SSH - PASS (tick)
  • 233.5 Checking ONOS service - PASS (tick)
  • 233.6 Starting ONOS CLI sessions - PASS (tick)
  • 233.7 Checking ONOS nodes - PASS (tick)
  • 233.8 Checking ONOS applications - PASS (tick)
  • 233.9 Starting Mininet Topology - PASS (tick)
  • 233.10 Check whether the flow count is bigger than 104 - PASS (tick)
  • 233.11 Check whether all flow status are ADDED - PASS (tick)
  • 233.12 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_Before - PASS (tick)
  • 233.13 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_Before - PASS (tick)
  • 233.14 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 233.15 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 233.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 233.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 233.18 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_1 - PASS (tick)
  • 233.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_1 - PASS (tick)
  • 233.20 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 233.21 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 233.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_2 - PASS (tick)
  • 233.23 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_2 - PASS (tick)
  • 233.24 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 233.25 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 233.26 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_3 - PASS (tick)
  • 233.27 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_3 - PASS (tick)
  • 233.28 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 233.29 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 233.30 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_4 - PASS (tick)
  • 233.31 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_4 - FAIL (error)
    • IP connectivity failed
  • 233.32 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 233.33 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 233.34 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_5 - PASS (tick)
  • 233.35 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_5 - PASS (tick)
  • 233.36 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 233.37 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 233.38 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_6 - PASS (tick)
  • 233.39 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_6 - PASS (tick)
  • 233.40 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 233.41 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 233.42 Check whether the flow count is bigger than 104 - PASS (tick)
  • 233.43 Check whether all flow status are ADDED - PASS (tick)
  • 233.44 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_After - PASS (tick)
  • 233.45 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_After - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 233.46 Stopping Mininet - PASS (tick)
  • 233.47 Copying karaf logs - PASS (tick)

...