Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
HTML |
---|
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric2/lastSuccessfulBuild/artifact/SRDynamicConf_onos-1.13_20-builds_graph.jpg", alt="SRDynamicConf", style="width:525px;height:350px;border:0"> |
commit 8d6edf3216f7bce64b92852ce8e4efd2be46dcd9 d06925c4f05a7458ae9f2bbdf57eb905d11916fb (HEAD -] onos-1.13, origin/onos-1.13)
Author: snehaprem Matteo Scandolo [snehamatteo.prem@infosysscandolo@gmail.com]
AuthorDate: Thu Fri Nov 1 012 16:0209:21 39 2018 -04000700
Commit: Charles Chan [charles@opennetworking.orgSaurav Das [sauravdas@alumni.stanford.edu]
CommitDate: Fri Nov 2 069 00:1234:21 09 2018 +0000
route-remove cli command with source type addition
--
(cherry picked from commit 7828d01ca571190c1c3ba526dd24ef6e7399c79c)
Adding DHCP IpV6 support in VOLTHA Driver
Case 13: Changing port configuration from untagged 10 to tagged 10, with 2x2 leaf-spine topology and 3 ONOS instances - PASS
...
- 23.1 Apply cell to environment - PASS
- 23.2 Uninstalling ONOS package - PASS
- 23.3 Installing ONOS package - PASS
- 23.4 Set up ONOS secure SSH - PASS
- 23.5 Checking ONOS service - PASS
- 23.6 Starting ONOS CLI sessions - PASS
- 23.7 Checking ONOS nodes - PASS
- 23.8 Checking ONOS applications - PASS
- 23.9 Starting Mininet Topology - PASS
- 23.10 Check whether the flow count is bigger than 106 - PASS
- 23.11 Check whether all flow status are ADDED - PASS
- 23.12 Verify full connectivity for [u'h3', u'h4'] with tag CASE23_Before - PASS
- 23.13 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_Before - PASS
- 23.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 23.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 23.16 Check whether the flow count is bigger than 106 - PASS
- 23.17 Check whether all flow status are ADDED - FAIL
- Flow status is wrong!
- 23.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_After - PASS
- 23.19 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE23_After - PASS
- 23.20 Stopping Mininet - PASS
- 23.21 Copying karaf logs - PASS
Case 33: Changing port configuration from untagged 10 to untagged 110, with 2x2 leaf-spine topology and 3 ONOS instances -
...
FAIL
- 33.1 Apply cell to environment - PASS
- 33.2 Uninstalling ONOS package - PASS
- 33.3 Installing ONOS package - PASS
- 33.4 Set up ONOS secure SSH - PASS
- 33.5 Checking ONOS service - PASS
- 33.6 Starting ONOS CLI sessions - PASS
- 33.7 Checking ONOS nodes - PASS
- 33.8 Checking ONOS applications - PASS
- 33.9 Starting Mininet Topology - PASS
- 33.10 Check whether the flow count is bigger than 104 - PASS
- 33.11 Check whether all flow status are ADDED - PASS
- 33.12 Verify full connectivity for [u'h3', u'h4'] with tag CASE33_Before - PASS
- 33.13 Verify full connectivity for [u'h1', u'h2'] with tag CASE33_Before - PASS
- 33.14 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 33.15 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 33.16 Check whether the flow count is bigger than 104 - PASS
- 33.17 Check whether all flow status are ADDED - PASS FAIL
- Flow status is wrong!
- 33.18 Verify full connectivity for [u'h3', u'h4'] with tag CASE33_After - PASS
- 33.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE33_After - PASS
- 33.20 Stopping Mininet - PASS
- 33.21 Copying karaf logs - PASS
...
- 53.1 Apply cell to environment - PASS
- 53.2 Uninstalling ONOS package - PASS
- 53.3 Installing ONOS package - PASS
- 53.4 Set up ONOS secure SSH - PASS
- 53.5 Checking ONOS service - PASS
- 53.6 Starting ONOS CLI sessions - PASS
- 53.7 Checking ONOS nodes - PASS
- 53.8 Checking ONOS applications - PASS
- 53.9 Starting Mininet Topology - PASS
- 53.10 Check whether the flow count is bigger than 104 - PASS
- 53.11 Check whether all flow status are ADDED - PASS
- 53.12 Verify full connectivity for [u'h3', u'h4'] with tag CASE53_Before - PASS
- 53.13 Verify full connectivity for [u'h1', u'h2'] with tag CASE53_Before - PASS
- 53.14 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 53.15 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 53.16 Check whether the flow count is bigger than 104 - PASS
- 53.17 Check whether all flow status are ADDED - PASS
- 53.18 Verify full connectivity for [u'h3', u'h4'] with tag CASE53_After - PASS
- 53.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE53_After - PASS
- 53.20 Stopping Mininet - PASS
- 53.21 Copying karaf logs - PASS
Case 63: Changing port configuration from untagged 10 to tagged 120 with native 110, with 2x2 leaf-spine topology and 3 ONOS instances -
...
FAIL
- 63.1 Apply cell to environment - PASS
- 63.2 Uninstalling ONOS package - PASS
- 63.3 Installing ONOS package - PASS
- 63.4 Set up ONOS secure SSH - PASS
- 63.5 Checking ONOS service - PASS
- 63.6 Starting ONOS CLI sessions - PASS
- 63.7 Checking ONOS nodes - PASS
- 63.8 Checking ONOS applications - PASS
- 63.9 Starting Mininet Topology - PASS
- 63.10 Check whether the flow count is bigger than 104 - PASS
- 63.11 Check whether all flow status are ADDED - PASS
- 63.12 Verify full connectivity for [u'h3', u'h4'] with tag CASE63_Before - PASS
- 63.13 Verify full connectivity for [u'h1', u'h2'] with tag CASE63_Before - PASS
- 63.14 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 63.15 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 63.16 Check whether the flow count is bigger than 104 - PASS
- 63.17 Check whether all flow status are ADDED - PASS FAIL
- Flow status is wrong!
- 63.18 Verify full connectivity for [u'h3', u'h4'] with tag CASE63_After - PASS
- 63.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE63_After - PASS
- 63.20 Stopping Mininet - PASS
- 63.21 Copying karaf logs - PASS
...
- 113.1 Apply cell to environment - PASS
- 113.2 Uninstalling ONOS package - PASS
- 113.3 Installing ONOS package - PASS
- 113.4 Set up ONOS secure SSH - PASS
- 113.5 Checking ONOS service - PASS
- 113.6 Starting ONOS CLI sessions - PASS
- 113.7 Checking ONOS nodes - PASS
- 113.8 Checking ONOS applications - PASS
- 113.9 Starting Mininet Topology - PASS
- 113.10 Check whether the flow count is bigger than 104 - FAIL Flow count looks wrong: False
- PASS
- 113.11 Check whether all flow status are ADDED - PASS
- 113.12 Verify full connectivity for [u'h3', u'h4'] with tag CASE113_Before - FAIL IP connectivity failed
- PASS
- 113.13 Verify full connectivity for [u'h1', u'h2'] with tag CASE113_Before - FAIL IP connectivity failed
- PASS
- 113.14 Check whether the flow count of device of:0000000000000001 is bigger than 52 - FAIL Flow count looks wrong.
- PASS
- 113.15 Check whether the flow count of device of:0000000000000002 is bigger than 52 - FAIL Flow count looks wrong.
- PASS
- 113.16 Check whether the flow count is bigger than 104 - FAIL Flow count looks wrong: False
- PASS
- 113.17 Check whether all flow status are ADDED - PASS FAIL
- Flow status is wrong!
- 113.18 Verify full connectivity for [u'h3', u'h4'] with tag CASE113_After - FAIL IP connectivity failed
- PASS
- 113.19 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE113_After - PASS
- 113.20 Stopping Mininet - PASS
- 113.21 Copying karaf logs - PASS
Case 123: Changing port configuration from tagged 20 and native 10 to tagged 20 and native 110, with 2x2 leaf-spine topology and 3 ONOS instances -
...
FAIL
- 123.1 Apply cell to environment - PASS
- 123.2 Uninstalling ONOS package - PASS
- 123.3 Installing ONOS package - PASS
- 123.4 Set up ONOS secure SSH - PASS
- 123.5 Checking ONOS service - PASS
- 123.6 Starting ONOS CLI sessions - PASS
- 123.7 Checking ONOS nodes - PASS
- 123.8 Checking ONOS applications - PASS
- 123.9 Starting Mininet Topology - PASS
- 123.10 Check whether the flow count is bigger than 104 - PASS
- 123.11 Check whether all flow status are ADDED - PASS
- 123.12 Verify full connectivity for [u'h3', u'h4'] with tag CASE123_Before - PASS
- 123.13 Verify full connectivity for [u'h1', u'h2'] with tag CASE123_Before - PASS
- 123.14 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 123.15 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 123.16 Check whether the flow count is bigger than 104 - PASS
- 123.17 Check whether all flow status are ADDED - PASS FAIL
- Flow status is wrong!
- 123.18 Verify full connectivity for [u'h3', u'h4'] with tag CASE123_After - PASS
- 123.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE123_After - PASS
- 123.20 Stopping Mininet - PASS
- 123.21 Copying karaf logs - PASS
...
- 233.1 Apply cell to environment - PASS
- 233.2 Uninstalling ONOS package - PASS
- 233.3 Installing ONOS package - PASS
- 233.4 Set up ONOS secure SSH - PASS
- 233.5 Checking ONOS service - PASS
- 233.6 Starting ONOS CLI sessions - PASS
- 233.7 Checking ONOS nodes - PASS
- 233.8 Checking ONOS applications - PASS
- 233.9 Starting Mininet Topology - PASS
- 233.10 Check whether the flow count is bigger than 104 - FAIL
- Flow count looks wrong: False
- PASS
- 233. 233.11 Check whether all flow status are ADDED - PASS
- 233.12 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_Before - FAIL IP connectivity failed
- PASS
- 233.13 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_Before - FAIL
- IP connectivity failed
- PASS
- 233.14 Check whether the flow count of device of:0000000000000001 is bigger than 52 - FAIL
- Flow count looks wrong.
- PASS
- 233.15 Check whether the flow count of device of:0000000000000002 is bigger than 52 - FAIL
- Flow count looks wrong.
- PASS
- 233.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - FAIL
- Flow count looks wrong.
- PASS
- 233.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - FAIL Flow count looks wrong.
- PASS
- 233.18 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_1 - FAIL
- IP connectivity failed
- PASS
- 233.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_1 - PASS
- 233.20 Check whether the flow count of device of:0000000000000001 is bigger than 52 - FAIL Flow count looks wrong.
- PASS
- 233.21 Check whether the flow count of device of:0000000000000002 is bigger than 52 - FAIL Flow count looks wrong.
- PASS
- 233.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_2 - FAIL
- IP connectivity failed
- PASS
- 233.23 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_2 - PASS
- 233.24 Check whether the flow count of device of:0000000000000001 is bigger than 52 - FAIL
- Flow count looks wrong.
- PASS
- 233.25 Check whether the flow count of device of:0000000000000002 is bigger than 52 - FAIL
- Flow count looks wrong.
- PASS
- 233.26 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_3 - FAIL
- IP connectivity failed
- PASS
- 233.27 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_3 - PASS
- 233.28 Check whether the flow count of device of:0000000000000001 is bigger than 52 - FAIL Flow count looks wrong.
- PASS
- 233.29 Check whether the flow count of device of:0000000000000002 is bigger than 52 - FAIL
- Flow count looks wrong.
- PASS
- 233.30 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_4 - FAIL IP connectivity failed
- PASS
- 233.31 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_4 - FAIL
- IP connectivity failed
- 233.32 Check whether the flow count of device of:0000000000000001 is bigger than 52 - FAIL Flow count looks wrong.
- PASS
- 233.33 Check whether the flow count of device of:0000000000000002 is bigger than 52 - FAIL Flow count looks wrong.
- PASS
- 233.34 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_5 - FAIL IP connectivity failed
- PASS
- 233.35 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_5 - PASS
- 233.36 Check whether the flow count of device of:0000000000000001 is bigger than 52 - FAIL Flow count looks wrong.
- PASS
- 233.37 Check whether the flow count of device of:0000000000000002 is bigger than 52 - FAIL Flow count looks wrong.
- PASS
- 233.38 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_6 - FAIL IP connectivity failed
- PASS
- 233.39 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_6 - PASS
- 233.40 Check whether the flow count of device of:0000000000000001 is bigger than 52 - FAIL Flow count looks wrong.
- PASS
- 233.41 Check whether the flow count of device of:0000000000000002 is bigger than 52 - FAIL Flow count looks wrong.
- PASS
- 233.42 Check whether the flow count is bigger than 104 - FAIL Flow count looks wrong: False
- PASS
- 233.43 Check whether all flow status are ADDED - PASS
- 233.44 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_After - FAIL IP connectivity failed
- PASS
- 233.45 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_After - FAIL
- IP connectivity failed
- 233.46 Stopping Mininet - PASS
- 233.47 Copying karaf logs - PASS
...