Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Published from Jenkins build: https://jenkins.onosproject.org/job/SR-pipeline-1.12/104/

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric3/lastSuccessfulBuild/artifact/SRDynamicConf_onos-1.12_20-builds_graph.jpg", alt="SRDynamicConf", style="width:525px;height:350px;border:0">

commit eeeab1f6050fd39ad555f33946af43af2c36bf7a 1c188d3f2e89774974451e2283aab2cb3ed525a0 (HEAD -] onos-1.12, origin/onos-1.12)
Author: Andrea Campanella Thomas Vachuska [andrea@opennetworkingtom@opennetworking.org]
AuthorDate: Fri Mon Apr 13 1216 14:1402:48 18 2018 +0200-0700
Commit: Andrea Campanella Thomas Vachuska [andrea@opennetworkingtom@opennetworking.org]
CommitDate: Fri Mon Apr 13 1216 22:30:02 16 2018 +0200
T3: tracing only through flows in ADDED state0000

Making REST API port as a command-line option for various admin commands.
--
(cherry picked from commit a7be50dc8856d223d49ef3157f763461cade2a8c)

Case 13: Changing port configuration from untagged 10 to tagged 10, with 2x2 leaf-spine topology and 3 ONOS instances - PASS

...

  • 13.1 Constructing test variables - No Result (warning)
  • 13.2 Constructing test variables - PASS (tick)
  • 13.3 Apply cell to environment - PASS (tick)
  • 13.4 Uninstalling ONOS package - PASS (tick)
  • 13.5 Creating ONOS package - PASS (tick)
  • 13.6 Installing ONOS package - PASS (tick)
  • 13.7 Set up ONOS secure SSH - PASS (tick)
  • 13.8 Checking ONOS service - PASS (tick)
  • 13.9 Starting ONOS CLI sessions - PASS (tick)
  • 13.10 Starting Mininet Topology - PASS (tick)
  • 13.11 Check whether the flow count is bigger than 104 - PASS (tick)
  • 13.12 Check whether all flow status are ADDED - PASS (tick)
  • 13.13 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE13_Before - PASS (tick)
  • 13.14 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 13.15 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 13.16 Check whether the flow count is bigger than 104 - PASS (tick)
  • 13.17 Check whether all flow status are ADDED - PASS (tick)
  • 13.18 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE13_After - PASS (tick)
  • 13.19 Stopping Mininet - PASS (tick)
  • 13.20 Copying karaf logs - PASS (tick)

Case 23: Changing port configuration from untagged 10 to tagged 20 and native 10, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 23.1 Apply cell to environment - PASS (tick)
  • 23.2 Uninstalling ONOS package - PASS (tick)
  • 23.3 Installing ONOS package - PASS (tick)
  • 23.4 Set up ONOS secure SSH - PASS (tick)
  • 23.5 Checking ONOS service - PASS (tick)
  • 23.6 Starting ONOS CLI sessions - PASS (tick)
  • 23.7 Starting Mininet Topology - PASS (tick)
  • 23.8 Check whether the flow count is bigger than 106 - PASS (tick)
  • 23.9 Check whether all flow status are ADDED - PASS (tick)
  • 23.10 Verify full connectivity for [u'h3', u'h4'] with tag CASE23_Before - PASS (tick)
  • 23.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_Before - PASS (tick)
  • 23.12 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 23.13 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 23.14 Check whether the flow count is bigger than 106 - PASS (tick)
  • 23.15 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 23.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_After - PASS (tick)
  • 23.17 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE23_After - PASS (tick)
  • 23.18 Stopping Mininet - PASS (tick)
  • 23.19 Copying karaf logs - PASS (tick)

...

  • 33.1 Apply cell to environment - PASS (tick)
  • 33.2 Uninstalling ONOS package - PASS (tick)
  • 33.3 Installing ONOS package - PASS (tick)
  • 33.4 Set up ONOS secure SSH - PASS (tick)
  • 33.5 Checking ONOS service - PASS (tick)
  • 33.6 Starting ONOS CLI sessions - PASS (tick)
  • 33.7 Starting Mininet Topology - PASS (tick)
  • 33.8 Check whether the flow count is bigger than 104 - PASS (tick)
  • 33.9 Check whether all flow status are ADDED - PASS (tick)
  • 33.10 Verify full connectivity for [u'h3', u'h4'] with tag CASE33_Before - PASS (tick)
  • 33.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE33_Before - PASS (tick)
  • 33.12 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 33.13 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 33.14 Check whether the flow count is bigger than 104 - PASS (tick)
  • 33.15 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 33.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE33_After - PASS (tick)
  • 33.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE33_After - PASS (tick)
  • 33.18 Stopping Mininet - PASS (tick)
  • 33.19 Copying karaf logs - PASS (tick)

Case 43: Changing port configuration from untagged 10 to tagged 20, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 43.1 Apply cell to environment - PASS (tick)
  • 43.2 Uninstalling ONOS package - PASS (tick)
  • 43.3 Installing ONOS package - PASS (tick)
  • 43.4 Set up ONOS secure SSH - PASS (tick)
  • 43.5 Checking ONOS service - PASS (tick)
  • 43.6 Starting ONOS CLI sessions - PASS (tick)
  • 43.7 Starting Mininet Topology - PASS (tick)
  • 43.8 Check whether the flow count is bigger than 104 - PASS (tick)
  • 43.9 Check whether all flow status are ADDED - PASS (tick)
  • 43.10 Verify full connectivity for [u'h3', u'h4'] with tag CASE43_Before - PASS (tick)
  • 43.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE43_Before - PASS (tick)
  • 43.12 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 43.13 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 43.14 Check whether the flow count is bigger than 104 - PASS (tick)
  • 43.15 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 43.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE43_After - PASS (tick)
  • 43.17 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE43_After - PASS (tick)
  • 43.18 Stopping Mininet - PASS (tick)
  • 43.19 Copying karaf logs - PASS (tick)

...

  • 213.1 Apply cell to environment - PASS (tick)
  • 213.2 Uninstalling ONOS package - PASS (tick)
  • 213.3 Installing ONOS package - PASS (tick)
  • 213.4 Set up ONOS secure SSH - PASS (tick)
  • 213.5 Checking ONOS service - PASS (tick)
  • 213.6 Starting ONOS CLI sessions - PASS (tick)
  • 213.7 Starting Mininet Topology - PASS (tick)
  • 213.8 Check whether the flow count is bigger than 106 - PASS (tick)
  • 213.9 Check whether all flow status are ADDED - PASS (tick)
  • 213.10 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE213_Before - PASS (tick)
  • 213.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE213_Before - PASS (tick)
  • 213.12 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 213.13 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 213.14 Check whether the flow count is bigger than 106 - PASS (tick)
  • 213.15 Check whether all flow status are ADDED - PASS (tick)
  • 213.16 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE213_After - PASS (tick)
  • 213.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE213_After - PASS (tick)
  • 213.18 Stopping Mininet - PASS (tick)
  • 213.19 Copying karaf logs - PASS (tick)

Case 223: Changing port configuration from tagged 20 and native 10 to tagged 120 and native 10, with 2x2 leaf-spine topology and 3 ONOS instances -

...

PASS

  • 223.1 Apply cell to environment - PASS (tick)
  • 223.2 Uninstalling ONOS package - PASS (tick)
  • 223.3 Installing ONOS package - PASS (tick)
  • 223.4 Set up ONOS secure SSH - PASS (tick)
  • 223.5 Checking ONOS service - PASS (tick)
  • 223.6 Starting ONOS CLI sessions - PASS (tick)
  • 223.7 Starting Mininet Topology - PASS (tick)
  • 223.8 Check whether the flow count is bigger than 106 - PASS (tick)
  • 223.9 Check whether all flow status are ADDED - PASS (tick)
  • 223.10 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE223_Before - PASS (tick)
  • 223.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE223_Before - PASS (tick)
  • 223.12 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 223.13 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 223.14 Check whether the flow count is bigger than 106 - PASS (tick)
  • 223.15 Check whether all flow status are ADDED - FAIL (error)
  • Flow status is wrong!
  • PASS (tick)
  • 223.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE223_After - PASS (tick)
  • 223.17 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE223_After - PASS (tick)
  • 223.18 Stopping Mininet - PASS (tick)
  • 223.19 Copying karaf logs - PASS (tick)

...

  • 243.1 Apply cell to environment - PASS (tick)
  • 243.2 Uninstalling ONOS package - PASS (tick)
  • 243.3 Installing ONOS package - PASS (tick)
  • 243.4 Set up ONOS secure SSH - PASS (tick)
  • 243.5 Checking ONOS service - PASS (tick)
  • 243.6 Starting ONOS CLI sessions - PASS (tick)
  • 243.7 Starting Mininet Topology - PASS (tick)
  • 243.8 Check whether the flow count is bigger than 104 - PASS (tick)
  • 243.9 Check whether all flow status are ADDED - PASS (tick)
  • 243.10 Verify full connectivity for [u'h1', u'h2', u'h5'] with tag CASE243_Before - FAIL (error)
    • IP connectivity failed
  • 243.11 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 243.12 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 243.13 Check whether the flow count is bigger than 104 - PASS (tick)
  • 243.14 Check whether all flow status are ADDED - PASS (tick)
  • 243.15 Verify full connectivity for [u'h1', u'h2', u'h5'] with tag CASE243_After - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 243.16 Stopping Mininet - PASS (tick)
  • 243.17 Copying karaf logs - PASS (tick)