Case 13: Changing port configuration from untagged 10 to tagged 10, with 2x2 leaf-spine topology and 3 ONOS instances - PASS

  • 13.1 Constructing test variables - No Result (warning) 13.2 Constructing test variables - PASS (tick)
  • 13.3 2 Apply cell to environment - PASS (tick)
  • 13.4 3 Uninstalling ONOS package - PASS (tick)
  • 13.5 4 Creating ONOS package - PASS (tick)
  • 13.6 5 Installing ONOS package - PASS (tick)
  • 13.7 6 Set up ONOS secure SSH - PASS (tick)
  • 13.8 7 Checking ONOS service - PASS (tick)
  • 13.9 8 Starting ONOS CLI sessions - PASS (tick)
  • 13.10 9 Starting Mininet Topology - PASS (tick)
  • 13.11 10 Check whether the flow count is bigger than 104 - PASS (tick)
  • 13.12 11 Check whether all flow status are ADDED - PASS (tick)
  • 13.13 12 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE13_Before - PASS (tick)
  • 13.14 13 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 13.15 14 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 13.16 15 Check whether the flow count is bigger than 104 - PASS (tick)
  • 13.17 16 Check whether all flow status are ADDED - PASS (tick)
  • 13.18 17 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE13_After - PASS (tick)
  • 13.19 18 Stopping Mininet - PASS (tick)
  • 13.20 19 Copying karaf logs - PASS (tick)

...

  • 103.1 Apply cell to environment - PASS (tick)
  • 103.2 Uninstalling ONOS package - PASS (tick)
  • 103.3 Installing ONOS package - PASS (tick)
  • 103.4 Set up ONOS secure SSH - PASS (tick)
  • 103.5 Checking ONOS service - PASS (tick)
  • 103.6 Starting ONOS CLI sessions - PASS (tick)
  • 103.7 Starting Mininet Topology - PASS (tick)
  • 103.8 Check whether the flow count is bigger than 104 - PASS (tick)
  • 103.9 Check whether all flow status are ADDED - PASS (tick)
  • 103.10 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE103_Before - PASS (tick)
  • 103.11 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 103.12 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 103.13 Check whether the flow count is bigger than 104 - PASS (tick)
  • 103.14 Check whether all flow status are ADDED - PASS (tick)
  • 103.15 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE103_After - PASS (tick)
  • 103.16 Stopping Mininet - PASS (tick)
  • 103.17 Copying karaf logs - PASS (tick)

Case 113: Changing port configuration from tagged 20 and native 10 to tagged 20, with 2x2 leaf-spine topology and 3 ONOS instances -

...

PASS

  • 113.1 Apply cell to environment - PASS (tick)
  • 113.2 Uninstalling ONOS package - PASS (tick)
  • 113.3 Installing ONOS package - PASS (tick)
  • 113.4 Set up ONOS secure SSH - PASS (tick)
  • 113.5 Checking ONOS service - PASS (tick)
  • 113.6 Starting ONOS CLI sessions - PASS (tick)
  • 113.7 Starting Mininet Topology - PASS (tick)
  • 113.8 Check whether the flow count is bigger than 104 - PASS (tick)
  • 113.9 Check whether all flow status are ADDED - PASS (tick)
  • 113.10 Verify full connectivity for [u'h3', u'h4'] with tag CASE113_Before - PASS (tick)
  • 113.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE113_Before - PASS (tick)
  • 113.12 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 113.13 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 113.14 Check whether the flow count is bigger than 104 - PASS (tick)
  • 113.15 Check whether all flow status are ADDED - FAIL (error)
  • Flow status is wrong!
  • PASS (tick)
  • 113.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE113_After - PASS (tick)
  • 113.17 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE113_After - PASS (tick)
  • 113.18 Stopping Mininet - PASS (tick)
  • 113.19 Copying karaf logs - PASS (tick)

Case 123: Changing port configuration from tagged 20 and native 10 to tagged 20 and native 110, with 2x2 leaf-spine topology and 3 ONOS instances -

...

PASS

  • 123.1 Apply cell to environment - PASS (tick)
  • 123.2 Uninstalling ONOS package - PASS (tick)
  • 123.3 Installing ONOS package - PASS (tick)
  • 123.4 Set up ONOS secure SSH - PASS (tick)
  • 123.5 Checking ONOS service - PASS (tick)
  • 123.6 Starting ONOS CLI sessions - PASS (tick)
  • 123.7 Starting Mininet Topology - PASS (tick)
  • 123.8 Check whether the flow count is bigger than 104 - PASS (tick)
  • 123.9 Check whether all flow status are ADDED - PASS (tick)
  • 123.10 Verify full connectivity for [u'h3', u'h4'] with tag CASE123_Before - PASS (tick)
  • 123.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE123_Before - PASS (tick)
  • 123.12 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 123.13 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 123.14 Check whether the flow count is bigger than 104 - PASS (tick)
  • 123.15 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • PASS (tick)
  • 123.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE123_After - PASS (tick)
  • 123.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE123_After - PASS (tick)
  • 123.18 Stopping Mininet - PASS (tick)
  • 123.19 Copying karaf logs - PASS (tick)

...

  • 153.1 Apply cell to environment - PASS (tick)
  • 153.2 Uninstalling ONOS package - PASS (tick)
  • 153.3 Installing ONOS package - PASS (tick)
  • 153.4 Set up ONOS secure SSH - PASS (tick)
  • 153.5 Checking ONOS service - PASS (tick)
  • 153.6 Starting ONOS CLI sessions - PASS (tick)
  • 153.7 Starting Mininet Topology - PASS (tick)
  • 153.8 Check whether the flow count is bigger than 106 - PASS (tick)
  • 153.9 Check whether all flow status are ADDED - PASS (tick)
  • 153.10 Verify full connectivity for [u'h3', u'h4'] with tag CASE153_Before - PASS (tick)
  • 153.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE153_Before - PASS (tick)
  • 153.12 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 153.13 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 153.14 Check whether the flow count is bigger than 106 - PASS (tick)
  • 153.15 Check whether all flow status are ADDED - PASS (tick)
  • 153.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE153_After - PASS (tick)
  • 153.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE153_After - PASS (tick)
  • 153.18 Stopping Mininet - PASS (tick)
  • 153.19 Copying karaf logs - PASS (tick)

Case 163: Changing port configuration from untagged 10 to tagged 20 and native 10, with 2x2 leaf-spine topology and 3 ONOS instances -

...

PASS

  • 163.1 Apply cell to environment - PASS (tick)
  • 163.2 Uninstalling ONOS package - PASS (tick)
  • 163.3 Installing ONOS package - PASS (tick)
  • 163.4 Set up ONOS secure SSH - PASS (tick)
  • 163.5 Checking ONOS service - PASS (tick)
  • 163.6 Starting ONOS CLI sessions - PASS (tick)
  • 163.7 Starting Mininet Topology - PASS (tick)
  • 163.8 Check whether the flow count is bigger than 106 - PASS (tick)
  • 163.9 Check whether all flow status are ADDED - PASS (tick)
  • 163.10 Verify full connectivity for [u'h3', u'h4'] with tag CASE163_Before - PASS (tick)
  • 163.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE163_Before - PASS (tick)
  • 163.12 Check whether the flow count of device of:0000000000000001 is bigger than 53 - FAIL (error)
    • Flow count looks wrong.
  • PASS (tick)
  • 163.13 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 163.14 Check whether the flow count is bigger than 106 - PASS (tick)
  • 163.15 Check whether all flow status are ADDED - PASS (tick)
  • 163.16 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE163_After - PASS (tick)
  • 163.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE163_After - PASS (tick)
  • 163.18 Stopping Mininet - PASS (tick)
  • 163.19 Copying karaf logs - PASS (tick)

...

  • 213.1 Apply cell to environment - PASS (tick)
  • 213.2 Uninstalling ONOS package - PASS (tick)
  • 213.3 Installing ONOS package - PASS (tick)
  • 213.4 Set up ONOS secure SSH - PASS (tick)
  • 213.5 Checking ONOS service - PASS (tick)
  • 213.6 Starting ONOS CLI sessions - PASS (tick)
  • 213.7 Starting Mininet Topology - PASS (tick)
  • 213.8 Check whether the flow count is bigger than 106 - PASS (tick)
  • 213.9 Check whether all flow status are ADDED - PASS (tick)
  • 213.10 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE213_Before - PASS (tick)
  • 213.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE213_Before - PASS (tick)
  • 213.12 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 213.13 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 213.14 Check whether the flow count is bigger than 106 - PASS (tick)
  • 213.15 Check whether all flow status are ADDED - PASS (tick)
  • 213.16 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE213_After - PASS (tick)
  • 213.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE213_After - PASS (tick)
  • 213.18 Stopping Mininet - PASS (tick)
  • 213.19 Copying karaf logs - PASS (tick)

Case 223: Changing port configuration from tagged 20 and native 10 to tagged 120 and native 10, with 2x2 leaf-spine topology and 3 ONOS instances -

...

PASS

  • 223.1 Apply cell to environment - PASS (tick)
  • 223.2 Uninstalling ONOS package - PASS (tick)
  • 223.3 Installing ONOS package - PASS (tick)
  • 223.4 Set up ONOS secure SSH - PASS (tick)
  • 223.5 Checking ONOS service - PASS (tick)
  • 223.6 Starting ONOS CLI sessions - PASS (tick)
  • 223.7 Starting Mininet Topology - PASS (tick)
  • 223.8 Check whether the flow count is bigger than 106 - PASS (tick)
  • 223.9 Check whether all flow status are ADDED - PASS (tick)
  • 223.10 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE223_Before - PASS (tick)
  • 223.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE223_Before - PASS (tick)
  • 223.12 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 223.13 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 223.14 Check whether the flow count is bigger than 106 - PASS (tick)
  • 223.15 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • PASS (tick)
  • 223 223.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE223_After - PASS (tick)
  • 223.17 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE223_After - PASS (tick)
  • 223.18 Stopping Mininet - PASS (tick)
  • 223.19 Copying karaf logs - PASS (tick)

...

  • 233.1 Apply cell to environment - PASS (tick)
  • 233.2 Uninstalling ONOS package - PASS (tick)
  • 233.3 Installing ONOS package - PASS (tick)
  • 233.4 Set up ONOS secure SSH - PASS (tick)
  • 233.5 Checking ONOS service - PASS (tick)
  • 233.6 Starting ONOS CLI sessions - PASS (tick)
  • 233.7 Starting Mininet Topology - PASS (tick)
  • 233.8 Check whether the flow count is bigger than 104 - PASS (tick)
  • 233.9 Check whether all flow status are ADDED - PASS (tick)
  • 233.10 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_Before - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 233.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_Before - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 233.12 Check whether the flow count of device of:0000000000000001 is bigger than 52 - FAIL (error)
    • Flow count looks wrong.
  • PASS (tick)
  • 233.13 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 233.14 Check whether the flow count of device of:0000000000000001 is bigger than 52 - FAIL (error)
  • Flow count looks wrong.
  • PASS (tick)
  • 233.15 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 233.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_1 - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 233.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_1 - PASS (tick)
  • 233.18 Check whether the flow count of device of:0000000000000001 is bigger than 52 - FAIL (error)
  • Flow count looks wrong.
  • PASS (tick)
  • 233.19 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 233.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_2 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 233.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_2 - PASS (tick)
  • 233.22 Check whether the flow count of device of:0000000000000001 is bigger than 52 - FAIL (error)
    • Flow count looks wrong.
  • PASS (tick)
  • 233.23 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 233.24 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_3 - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 233.25 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_3 - PASS (tick)
  • 233.26 Check whether the flow count of device of:0000000000000001 is bigger than 52 - FAIL (error)
    • Flow count looks wrong.
  • PASS (tick)
  • 233.27 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 233.28 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_4 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 233.29 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_4 - FAIL (error)
    • IP connectivity failed
  • 233.30 Check whether the flow count of device of:0000000000000001 is bigger than 52 - FAIL (error)
    • Flow count looks wrong.
  • PASS (tick)
  • 233.31 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 233.32 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_5 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 233.33 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_5 - PASS (tick)
  • 233.34 Check whether the flow count of device of:0000000000000001 is bigger than 52 - FAIL (error)
    • Flow count looks wrong.
  • PASS (tick)
  • 233.35 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 233.36 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_6 - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 233.37 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_6 - PASS (tick)
  • 233.38 Check whether the flow count of device of:0000000000000001 is bigger than 52 - FAIL (error)
    • Flow count looks wrong.
  • PASS (tick)
  • 233.39 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 233.40 Check whether the flow count is bigger than 104 - PASS (tick)
  • 233.41 Check whether all flow status are ADDED - PASS (tick)
  • 233.42 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_After - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 233.43 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_After - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 233.44 Stopping Mininet - PASS (tick)
  • 233.45 Copying karaf logs - PASS (tick)

...