Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
HTML |
---|
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric3/lastSuccessfulBuild/artifact/SRDynamicConf_onos-1.12_20-builds_graph.jpg", alt="SRDynamicConf", style="width:525px;height:350px;border:0"> |
commit 9f832343ebd760246928e54c86080227a1ebfdf4 db6e7b990e7c5f7cf4309e985fabc85410581ed6 (HEAD -] onos-1.12, origin/onos-1.12)
Author: Pier [pierluigi.ventre@cnit.itYuta HIGUCHI [y-higuchi@ak.jp.nec.com]
AuthorDate: Mon Mar 26 Thu May 17 16:5627:18 51 2018 -0700
Commit: Thomas Vachuska [tom@opennetworking.orgYuta HIGUCHI [y-higuchi@ak.jp.nec.com]
CommitDate: Tue Thu May 15 2017 16:0327:11 51 2018 +0000
Fix testUninstallAndInstallNonDisruptive test-0700
Detach yms from build
Case 13: Changing port configuration from untagged 10 to tagged 10, with 2x2 leaf-spine topology and 3 ONOS instances -
...
FAIL
- 13.1 Constructing test variables - PASS
- 13.2 Apply cell to environment - PASS
- 13.3 Uninstalling ONOS package - PASS
- 13.4 Creating ONOS package - PASS
- 13.5 Installing ONOS package - PASS
- 13.6 Set up ONOS secure SSH - PASS
- 13.7 Checking ONOS service - PASS
- 13.8 Starting ONOS CLI sessions - PASS
- 13.9 Starting Mininet Topology - PASS
- 13.10 Check whether the flow count is bigger than 104 - PASS
- 13.11 Check whether all flow status are ADDED - PASS
- 13.12 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE13_Before - PASS FAIL
- IP connectivity failed
- 13.13 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 13.14 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 13.15 Check whether the flow count is bigger than 104 - PASS
- 13.16 Check whether all flow status are ADDED - PASS
- 13.17 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE13_After - PASS FAIL
- IP connectivity failed
- 13.18 Stopping Mininet - PASS
- 13.19 Copying karaf logs - PASS
...
- 103.1 Apply cell to environment - PASS
- 103.2 Uninstalling ONOS package - PASS
- 103.3 Installing ONOS package - PASS
- 103.4 Set up ONOS secure SSH - PASS
- 103.5 Checking ONOS service - PASS
- 103.6 Starting ONOS CLI sessions - PASS
- 103.7 Starting Mininet Topology - PASS
- 103.8 Check whether the flow count is bigger than 104 - PASS
- 103.9 Check whether all flow status are ADDED - PASS
- 103.10 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE103_Before - PASS
- 103.11 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 103.12 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 103.13 Check whether the flow count is bigger than 104 - PASS
- 103.14 Check whether all flow status are ADDED - PASS
- 103.15 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE103_After - PASS
- 103.16 Stopping Mininet - PASS
- 103.17 Copying karaf logs - PASS
Case 113: Changing port configuration from tagged 20 and native 10 to tagged 20, with 2x2 leaf-spine topology and 3 ONOS instances -
...
FAIL
- 113.1 Apply cell to environment - PASS
- 113.2 Uninstalling ONOS package - PASS
- 113.3 Installing ONOS package - PASS
- 113.4 Set up ONOS secure SSH - PASS
- 113.5 Checking ONOS service - PASS
- 113.6 Starting ONOS CLI sessions - PASS
- 113.7 Starting Mininet Topology - PASS
- 113.8 Check whether the flow count is bigger than 104 - PASS
- 113.9 Check whether all flow status are ADDED - PASS
- 113.10 Verify full connectivity for [u'h3', u'h4'] with tag CASE113_Before - PASS
- 113.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE113_Before - PASS
- 113.12 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 113.13 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 113.14 Check whether the flow count is bigger than 104 - PASS
- 113.15 Check whether all flow status are ADDED - PASS FAIL
- Flow status is wrong!
- 113.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE113_After - PASS
- 113.17 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE113_After - PASS
- 113.18 Stopping Mininet - PASS
- 113.19 Copying karaf logs - PASS
Case 123: Changing port configuration from tagged 20 and native 10 to tagged 20 and native 110, with 2x2 leaf-spine topology and 3 ONOS instances -
...
FAIL
- 123.1 Apply cell to environment - PASS
- 123.2 Uninstalling ONOS package - PASS
- 123.3 Installing ONOS package - PASS
- 123.4 Set up ONOS secure SSH - PASS
- 123.5 Checking ONOS service - PASS
- 123.6 Starting ONOS CLI sessions - PASS
- 123.7 Starting Mininet Topology - PASS
- 123.8 Check whether the flow count is bigger than 104 - PASS
- 123.9 Check whether all flow status are ADDED - PASS
- 123.10 Verify full connectivity for [u'h3', u'h4'] with tag CASE123_Before - PASS
- 123.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE123_Before - PASS
- 123.12 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 123.13 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 123.14 Check whether the flow count is bigger than 104 - PASS
- 123.15 Check whether all flow status are ADDED - PASS FAIL
- Flow status is wrong!
- 123.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE123_After - PASS
- 123.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE123_After - PASS
- 123.18 Stopping Mininet - PASS
- 123.19 Copying karaf logs - PASS
Case 133: Changing port configuration from tagged 20 and native 10 to tagged 120 and native 10, with 2x2 leaf-spine topology and 3 ONOS instances -
...
FAIL
- 133.1 Apply cell to environment - PASS
- 133.2 Uninstalling ONOS package - PASS
- 133.3 Installing ONOS package - PASS
- 133.4 Set up ONOS secure SSH - PASS
- 133.5 Checking ONOS service - PASS
- 133.6 Starting ONOS CLI sessions - PASS
- 133.7 Starting Mininet Topology - PASS
- 133.8 Check whether the flow count is bigger than 104 - PASS
- 133.9 Check whether all flow status are ADDED - PASS
- 133.10 Verify full connectivity for [u'h3', u'h4'] with tag CASE133_Before - PASS FAIL
- IP connectivity failed
- 133.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE133_Before - PASS
- 133.12 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 133.13 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 133.14 Check whether the flow count is bigger than 104 - PASS
- 133.15 Check whether all flow status are ADDED - PASS
- 133.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE133_After - PASS
- 133.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE133_After - PASS
- 133.18 Stopping Mininet - PASS
- 133.19 Copying karaf logs - PASS
...
- 203.1 Apply cell to environment - PASS
- 203.2 Uninstalling ONOS package - PASS
- 203.3 Installing ONOS package - PASS
- 203.4 Set up ONOS secure SSH - PASS
- 203.5 Checking ONOS service - PASS
- 203.6 Starting ONOS CLI sessions - PASS
- 203.7 Starting Mininet Topology - PASS
- 203.8 Check whether the flow count is bigger than 106 - PASS
- 203.9 Check whether all flow status are ADDED - PASS
- 203.10 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE203_Before - PASS
- 203.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE203_Before - PASS
- 203.12 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 203.13 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 203.14 Check whether the flow count is bigger than 106 - PASS
- 203.15 Check whether all flow status are ADDED - PASS
- 203.16 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE203_After - PASS
- 203.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE203_After - PASS
- 203.18 Stopping Mininet - PASS
- 203.19 Copying karaf logs - PASS
Case 213: Changing port configuration from tagged 20 and native 10 to tagged 20 and native 110, with 2x2 leaf-spine topology and 3 ONOS instances -
...
FAIL
- 213.1 Apply cell to environment - PASS
- 213.2 Uninstalling ONOS package - PASS
- 213.3 Installing ONOS package - PASS
- 213.4 Set up ONOS secure SSH - PASS
- 213.5 Checking ONOS service - PASS
- 213.6 Starting ONOS CLI sessions - PASS
- 213.7 Starting Mininet Topology - PASS
- 213.8 Check whether the flow count is bigger than 106 - PASS
- 213.9 Check whether all flow status are ADDED - PASS
- 213.10 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE213_Before - PASS
- 213.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE213_Before - PASS
- 213.12 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 213.13 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS FAIL
- Flow count looks wrong.
- 213.14 Check whether the flow count is bigger than 106 - PASS
- 213.15 Check whether all flow status are ADDED - PASS
- 213.16 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE213_After - PASS
- 213.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE213_After - PASS
- 213.18 Stopping Mininet - PASS
- 213.19 Copying karaf logs - PASS
Case 223: Changing port configuration from tagged 20 and native 10 to tagged 120 and native 10, with 2x2 leaf-spine topology and 3 ONOS instances -
...
FAIL
- 223.1 Apply cell to environment - PASS
- 223.2 Uninstalling ONOS package - PASS
- 223.3 Installing ONOS package - PASS
- 223.4 Set up ONOS secure SSH - PASS
- 223.5 Checking ONOS service - PASS
- 223.6 Starting ONOS CLI sessions - PASS
- 223.7 Starting Mininet Topology - PASS
- 223.8 Check whether the flow count is bigger than 106 - PASS
- 223.9 Check whether all flow status are ADDED - PASS
- 223.10 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE223_Before - PASS
- 223.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE223_Before - PASS
- 223.12 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 223.13 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 223.14 Check whether the flow count is bigger than 106 - PASS
- 223.15 Check whether all flow status are ADDED - PASS FAIL
- Flow status is wrong!
- 223.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE223_After - PASS
- 223.17 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE223_After - PASS
- 223.18 Stopping Mininet - PASS
- 223.19 Copying karaf logs - PASS
...