Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
commit 9ba9e82813c8c903ac686fd00e3ff2d01049aa8c (HEAD -] onos-1.12, origin/onos-1.12)
Author: Yuta HIGUCHI [y-higuchi@ak.jp.nec.com]
AuthorDate: Fri May 18 12:07:51 2018 -0700
Commit: Yuta HIGUCHI [y-higuchi@ak.jp.nec.com]
CommitDate: Fri May 18 12:07:51 2018 -0700
Remove stale dependency to yms
Case 13: Changing port configuration from untagged 10 to tagged 10, with 2x2 leaf-spine topology and 3 ONOS instances -
...
FAIL
- 13.1 Constructing test variables - PASS
- 13.2 Apply cell to environment - PASS
- 13.3 Uninstalling ONOS package - PASS
- 13.4 Creating ONOS package - PASS
- 13.5 Installing ONOS package - PASS
- 13.6 Set up ONOS secure SSH - PASS
- 13.7 Checking ONOS service - PASS
- 13.8 Starting ONOS CLI sessions - PASS
- 13.9 Starting Mininet Topology - PASS
- 13.10 Check whether the flow count is bigger than 104 - PASS
- 13.11 Check whether all flow status are ADDED - PASS
- 13.12 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE13_Before - PASS FAIL
- IP connectivity failed
- 13.13 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 13.14 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 13.15 Check whether the flow count is bigger than 104 - PASS
- 13.16 Check whether all flow status are ADDED - PASS
- 13.17 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE13_After - PASS FAIL
- IP connectivity failed
- 13.18 Stopping Mininet - PASS
- 13.19 Copying karaf logs - PASS
...
- 103.1 Apply cell to environment - PASS
- 103.2 Uninstalling ONOS package - PASS
- 103.3 Installing ONOS package - PASS
- 103.4 Set up ONOS secure SSH - PASS
- 103.5 Checking ONOS service - PASS
- 103.6 Starting ONOS CLI sessions - PASS
- 103.7 Starting Mininet Topology - PASS
- 103.8 Check whether the flow count is bigger than 104 - PASS
- 103.9 Check whether all flow status are ADDED - PASS
- 103.10 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE103_Before - PASS
- 103.11 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 103.12 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 103.13 Check whether the flow count is bigger than 104 - PASS
- 103.14 Check whether all flow status are ADDED - PASS
- 103.15 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE103_After - PASS
- 103.16 Stopping Mininet - PASS
- 103.17 Copying karaf logs - PASS
Case 113: Changing port configuration from tagged 20 and native 10 to tagged 20, with 2x2 leaf-spine topology and 3 ONOS instances -
...
FAIL
- 113.1 Apply cell to environment - PASS
- 113.2 Uninstalling ONOS package - PASS
- 113.3 Installing ONOS package - PASS
- 113.4 Set up ONOS secure SSH - PASS
- 113.5 Checking ONOS service - PASS
- 113.6 Starting ONOS CLI sessions - PASS
- 113.7 Starting Mininet Topology - PASS
- 113.8 Check whether the flow count is bigger than 104 - PASS
- 113.9 Check whether all flow status are ADDED - PASS
- 113.10 Verify full connectivity for [u'h3', u'h4'] with tag CASE113_Before - PASS
- 113.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE113_Before - PASS
- 113.12 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 113.13 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 113.14 Check whether the flow count is bigger than 104 - PASS
- 113.15 Check whether all flow status are ADDED - PASS FAIL
- Flow status is wrong!
- 113.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE113_After - PASS
- 113.17 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE113_After - PASS
- 113.18 Stopping Mininet - PASS
- 113.19 Copying karaf logs - PASS
...