Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
HTML |
---|
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric3/lastSuccessfulBuild/artifact/SRDynamicConf_onos-1.12_20-builds_graph.jpg", alt="SRDynamicConf", style="width:525px;height:350px;border:0"> |
commit 9ba9e82813c8c903ac686fd00e3ff2d01049aa8c 7b1a66ba69d7cc18b3a35316d465377d765de71b (HEAD -] onos-1.12, origin/onos-1.12)
Author: Yuta HIGUCHI [y-higuchi@ak.jp.nec.comONOS Jenkins User [jenkins@onlab.us]
AuthorDate: Fri Tue May 18 1222 01:0751:51 54 2018 -0700+0000
Commit: Yuta HIGUCHI [y-higuchi@ak.jp.nec.comONOS Jenkins User [jenkins@onlab.us]
CommitDate: Fri Tue May 18 1222 01:0751:51 2018 -0700
Remove stale dependency to yms
54 2018 +0000
Starting snapshot 1.12.1-SNAPSHOT
Case 13: Changing port configuration from untagged 10 to tagged 10, with 2x2 leaf-spine topology and 3 ONOS instances -
...
PASS
- 13.1 Constructing test variables - PASS
- 13.2 Apply cell to environment - PASS
- 13.3 Uninstalling ONOS package - PASS
- 13.4 Creating ONOS package - PASS
- 13.5 Installing ONOS package - PASS
- 13.6 Set up ONOS secure SSH - PASS
- 13.7 Checking ONOS service - PASS
- 13.8 Starting ONOS CLI sessions - PASS
- 13.9 Starting Mininet Topology - PASS
- 13.10 Check whether the flow count is bigger than 104 - PASS
- 13.11 Check whether all flow status are ADDED - PASS
- 13.12 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE13_Before - FAIL
- IP connectivity failed
- PASS
- 13.13 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 13.14 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 13.15 Check whether the flow count is bigger than 104 - PASS
- 13.16 Check whether all flow status are ADDED - PASS
- 13.17 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE13_After - FAIL IP connectivity failed
- PASS
- 13.18 Stopping Mininet - PASS
- 13.19 Copying karaf logs - PASS
...
- 153.1 Apply cell to environment - PASS
- 153.2 Uninstalling ONOS package - PASS
- 153.3 Installing ONOS package - PASS
- 153.4 Set up ONOS secure SSH - PASS
- 153.5 Checking ONOS service - PASS
- 153.6 Starting ONOS CLI sessions - PASS
- 153.7 Starting Mininet Topology - PASS
- 153.8 Check whether the flow count is bigger than 106 - PASS
- 153.9 Check whether all flow status are ADDED - PASS
- 153.10 Verify full connectivity for [u'h3', u'h4'] with tag CASE153_Before - PASS
- 153.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE153_Before - PASS
- 153.12 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 153.13 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 153.14 Check whether the flow count is bigger than 106 - PASS
- 153.15 Check whether all flow status are ADDED - PASS
- 153.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE153_After - PASS
- 153.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE153_After - PASS
- 153.18 Stopping Mininet - PASS
- 153.19 Copying karaf logs - PASS
Case 163: Changing port configuration from untagged 10 to tagged 20 and native 10, with 2x2 leaf-spine topology and 3 ONOS instances -
...
FAIL
- 163.1 Apply cell to environment - PASS
- 163.2 Uninstalling ONOS package - PASS
- 163.3 Installing ONOS package - PASS
- 163.4 Set up ONOS secure SSH - PASS
- 163.5 Checking ONOS service - PASS
- 163.6 Starting ONOS CLI sessions - PASS
- 163.7 Starting Mininet Topology - PASS
- 163.8 Check whether the flow count is bigger than 106 - PASS
- 163.9 Check whether all flow status are ADDED - PASS
- 163.10 Verify full connectivity for [u'h3', u'h4'] with tag CASE163_Before - PASS
- 163.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE163_Before - PASS
- 163.12 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS FAIL
- Flow count looks wrong.
- 163.13 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 163.14 Check whether the flow count is bigger than 106 - PASS
- 163.15 Check whether all flow status are ADDED - PASS
- 163.16 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE163_After - PASS
- 163.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE163_After - PASS
- 163.18 Stopping Mininet - PASS
- 163.19 Copying karaf logs - PASS
...
- 243.1 Apply cell to environment - PASS
- 243.2 Uninstalling ONOS package - PASS
- 243.3 Installing ONOS package - PASS
- 243.4 Set up ONOS secure SSH - PASS
- 243.5 Checking ONOS service - PASS
- 243.6 Starting ONOS CLI sessions - PASS
- 243.7 Starting Mininet Topology - PASS
- 243.8 Check whether the flow count is bigger than 104 - PASS
- 243.9 Check whether all flow status are ADDED - PASS
- 243.10 Verify full connectivity for [u'h1', u'h2', u'h5'] with tag CASE243_Before - FAIL
- IP connectivity failed
- 243.11 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 243.12 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 243.13 Check whether the flow count is bigger than 104 - PASS
- 243.14 Check whether all flow status are ADDED - FAIL Flow status is wrong!
- PASS
- 243.15 Verify full connectivity for [u'h1', u'h2', u'h5'] with tag CASE243_After - FAIL
- IP connectivity failed
- 243.16 Stopping Mininet - PASS
- 243.17 Copying karaf logs - PASS