Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Published from Jenkins build: https://jenkins.onosproject.org/job/SR-pipeline-1.12/196/

...

  • 33.1 Apply cell to environment - PASS (tick)
  • 33.2 Uninstalling ONOS package - PASS (tick)
  • 33.3 Installing ONOS package - PASS (tick)
  • 33.4 Set up ONOS secure SSH - PASS (tick)
  • 33.5 Checking ONOS service - PASS (tick)
  • 33.6 Starting ONOS CLI sessions - PASS (tick)
  • 33.7 Starting Mininet Topology - PASS (tick)
  • 33.8 Check whether the flow count is bigger than 104 - PASS (tick)FAIL (error)
    • Flow count looks wrong: False
  • 33.9 Check whether all flow status are ADDED - PASS (tick)
  • 33.10 Verify full connectivity for [u'h3', u'h4'] with tag CASE33_Before - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 33.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE33_Before - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 33.12 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)FAIL (error)
    • Flow count looks wrong.
  • 33.13 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)FAIL (error)
    • Flow count looks wrong.
  • 33.14 Check whether the flow count is bigger than 104 - PASS (tick)FAIL (error)
    • Flow count looks wrong: False
  • 33.15 Check whether all flow status are ADDED - FAIL (error)
  • Flow status is wrong!
  • PASS (tick)
  • 33.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE33_After - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 33.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE33_After - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 33.18 Stopping Mininet - PASS (tick)
  • 33.19 Copying karaf logs - PASS (tick)

...

  • 53.1 Apply cell to environment - PASS (tick)
  • 53.2 Uninstalling ONOS package - PASS (tick)
  • 53.3 Installing ONOS package - PASS (tick)
  • 53.4 Set up ONOS secure SSH - PASS (tick)
  • 53.5 Checking ONOS service - PASS (tick)
  • 53.6 Starting ONOS CLI sessions - PASS (tick)
  • 53.7 Starting Mininet Topology - PASS (tick)
  • 53.8 Check whether the flow count is bigger than 104 - PASS (tick)
  • 53.9 Check whether all flow status are ADDED - PASS (tick)
  • 53.10 Verify full connectivity for [u'h3', u'h4'] with tag CASE53_Before - PASS (tick)
  • 53.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE53_Before - PASS (tick)
  • 53.12 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 53.13 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 53.14 Check whether the flow count is bigger than 104 - PASS (tick)
  • 53.15 Check whether all flow status are ADDED - PASS (tick)
  • 53.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE53_After - PASS (tick)
  • 53.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE53_After - PASS (tick)
  • 53.18 Stopping Mininet - PASS (tick)
  • 53.19 Copying karaf logs - PASS (tick)

Case 63: Changing port configuration from untagged 10 to tagged 120 with native 110, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 63.1 Apply cell to environment - PASS (tick)
  • 63.2 Uninstalling ONOS package - PASS (tick)
  • 63.3 Installing ONOS package - PASS (tick)
  • 63.4 Set up ONOS secure SSH - PASS (tick)
  • 63.5 Checking ONOS service - PASS (tick)
  • 63.6 Starting ONOS CLI sessions - PASS (tick)
  • 63.7 Starting Mininet Topology - PASS (tick)
  • 63.8 Check whether the flow count is bigger than 104 - PASS (tick)
  • 63.9 Check whether all flow status are ADDED - PASS (tick)
  • 63.10 Verify full connectivity for [u'h3', u'h4'] with tag CASE63_Before - PASS (tick)
  • 63.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE63_Before - PASS (tick)
  • 63.12 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 63.13 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 63.14 Check whether the flow count is bigger than 104 - PASS (tick)
  • 63.15 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 63.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE63_After - PASS (tick)
  • 63.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE63_After - PASS (tick)
  • 63.18 Stopping Mininet - PASS (tick)
  • 63.19 Copying karaf logs - PASS (tick)

...

  • 83.1 Apply cell to environment - PASS (tick)
  • 83.2 Uninstalling ONOS package - PASS (tick)
  • 83.3 Installing ONOS package - PASS (tick)
  • 83.4 Set up ONOS secure SSH - PASS (tick)
  • 83.5 Checking ONOS service - PASS (tick)
  • 83.6 Starting ONOS CLI sessions - PASS (tick)
  • 83.7 Starting Mininet Topology - PASS (tick)
  • 83.8 Check whether the flow count is bigger than 104 - PASS (tick)
  • 83.9 Check whether all flow status are ADDED - PASS (tick)
  • 83.10 Verify full connectivity for [u'h3', u'h4'] with tag CASE83_Before - PASS (tick)
  • 83.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE83_Before - PASS (tick)
  • 83.12 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 83.13 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 83.14 Check whether the flow count is bigger than 104 - PASS (tick)
  • 83.15 Check whether all flow status are ADDED - PASS (tick)
  • 83.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE83_After - PASS (tick)
  • 83.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE83_After - PASS (tick)
  • 83.18 Stopping Mininet - PASS (tick)
  • 83.19 Copying karaf logs - PASS (tick)

Case 93: Changing port configuration from tagged 10 to tagged 120 with native 110, with 2x2 leaf-spine topology and 3 ONOS instances -

...

PASS

  • 93.1 Apply cell to environment - PASS (tick)
  • 93.2 Uninstalling ONOS package - PASS (tick)
  • 93.3 Installing ONOS package - PASS (tick)
  • 93.4 Set up ONOS secure SSH - PASS (tick)
  • 93.5 Checking ONOS service - PASS (tick)
  • 93.6 Starting ONOS CLI sessions - PASS (tick)
  • 93.7 Starting Mininet Topology - PASS (tick)
  • 93.8 Check whether the flow count is bigger than 106 - PASS (tick)
  • 93.9 Check whether all flow status are ADDED - PASS (tick)
  • 93.10 Verify full connectivity for [u'h3', u'h4'] with tag CASE93_Before - PASS (tick)
  • 93.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE93_Before - PASS (tick)
  • 93.12 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 93.13 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 93.14 Check whether the flow count is bigger than 106 - PASS (tick)
  • 93.15 Check whether all flow status are ADDED - FAIL (error)
  • Flow status is wrong!
  • PASS (tick)
  • 93.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE93_After - PASS (tick)
  • 93.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE93_After - PASS (tick)
  • 93.18 Stopping Mininet - PASS (tick)
  • 93.19 Copying karaf logs - PASS (tick)

...

  • 213.1 Apply cell to environment - PASS (tick)
  • 213.2 Uninstalling ONOS package - PASS (tick)
  • 213.3 Installing ONOS package - PASS (tick)
  • 213.4 Set up ONOS secure SSH - PASS (tick)
  • 213.5 Checking ONOS service - PASS (tick)
  • 213.6 Starting ONOS CLI sessions - PASS (tick)
  • 213.7 Starting Mininet Topology - PASS (tick)
  • 213.8 Check whether the flow count is bigger than 106 - PASS (tick)
  • 213.9 Check whether all flow status are ADDED - PASS (tick)
  • 213.10 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE213_Before - PASS (tick)
  • 213.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE213_Before - PASS (tick)
  • 213.12 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 213.13 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 213.14 Check whether the flow count is bigger than 106 - PASS (tick)
  • 213.15 Check whether all flow status are ADDED - PASS (tick)
  • 213.16 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE213_After - PASS (tick)
  • 213.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE213_After - PASS (tick)
  • 213.18 Stopping Mininet - PASS (tick)
  • 213.19 Copying karaf logs - PASS (tick)

Case 223: Changing port configuration from tagged 20 and native 10 to tagged 120 and native 10, with 2x2 leaf-spine topology and 3 ONOS instances -

...

PASS

  • 223.1 Apply cell to environment - PASS (tick)
  • 223.2 Uninstalling ONOS package - PASS (tick)
  • 223.3 Installing ONOS package - PASS (tick)
  • 223.4 Set up ONOS secure SSH - PASS (tick)
  • 223.5 Checking ONOS service - PASS (tick)
  • 223.6 Starting ONOS CLI sessions - PASS (tick)
  • 223.7 Starting Mininet Topology - PASS (tick)
  • 223.8 Check whether the flow count is bigger than 106 - PASS (tick)
  • 223.9 Check whether all flow status are ADDED - PASS (tick)
  • 223.10 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE223_Before - PASS (tick)
  • 223.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE223_Before - PASS (tick)
  • 223.12 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 223.13 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 223.14 Check whether the flow count is bigger than 106 - PASS (tick)
  • 223.15 Check whether all flow status are ADDED - FAIL (error)
  • Flow status is wrong!
  • PASS (tick)
  • 223.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE223_After - PASS (tick)
  • 223.17 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE223_After - PASS (tick)
  • 223.18 Stopping Mininet - PASS (tick)
  • 223.19 Copying karaf logs - PASS (tick)

...