Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Published from Jenkins build: https://jenkins.onosproject.org/job/SR-pipeline-master/156/

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric4/lastSuccessfulBuild/artifact/SRBridging_master_20-builds_graph.jpg", alt="SRBridging", style="width:525px;height:350px;border:0">

commit c8b591ea1bef75289c09604c9df49f68d633962c a73f1065a96e89a0f848a360f73b7f4bad7d54bb (HEAD -] master, origin/master, origin/HEAD)
Author: Jordan Halterman Carmelo Cascone [jordan@opennetworkingcarmelo@opennetworking.org]
AuthorDate: Wed Mon Jul 11 0916 22:49:15 46 2018 -0700+0200
Commit: Thomas Vachuska Carmelo Cascone [tom@opennetworkingcarmelo@opennetworking.org]
CommitDate: Fri Mon Jul 13 1916 23:2211:29 15 2018 +0000
Ensure multimap events are published on replaceValues
Translate only certain groups to PI

Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR and 3 ONOS instances - PASS

...

  • 37.1 Apply cell to environment - PASS (tick)
  • 37.2 Uninstalling ONOS package - PASS (tick)
  • 37.3 Installing ONOS package - PASS (tick)
  • 37.4 Set up ONOS secure SSH - PASS (tick)
  • 37.5 Checking ONOS service - PASS (tick)
  • 37.6 Starting ONOS CLI sessions - PASS (tick)
  • 37.7 Starting Mininet Topology - PASS (tick)
  • 37.8 Check whether the flow count is bigger than 74 - PASS (tick)
  • 37.9 Check whether all flow status are ADDED - PASS (tick)
  • 37.10 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 37.11 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 37.12 Verify full connectivity for [u'h1', u'h2'] with tag CASE37 - PASS (tick)
  • 37.13 Verify full connectivity for [u'h3', u'h4'] with tag CASE37 - PASS (tick)
  • 37.14 Stopping Mininet - PASS (tick)
  • 37.15 Copying karaf logs - PASS (tick)

Case 38: Bridging test between two untagged hosts, one on vlan-untagged port and the other on vlan-native port, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 38.1 Apply cell to environment - PASS (tick)
  • 38.2 Uninstalling ONOS package - PASS (tick)
  • 38.3 Installing ONOS package - PASS (tick)
  • 38.4 Set up ONOS secure SSH - PASS (tick)
  • 38.5 Checking ONOS service - PASS (tick)
  • 38.6 Starting ONOS CLI sessions - PASS (tick)
  • 38.7 Starting Mininet Topology - PASS (tick)
  • 38.8 Check whether the flow count is bigger than 212 - PASS (tick)FAIL (error)
    • Flow count looks wrong: False
  • 38.9 Check whether all flow status are ADDED - PASS (tick)
  • 38.10 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong.
  • 38.11 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong.
  • 38.12 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong.
  • 38.13 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong.
  • 38.14 Verify full connectivity for [u'h1', u'h2'] with tag CASE38 - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 38.15 Verify full connectivity for [u'h3', u'h4'] with tag CASE38 - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 38.16 Stopping Mininet - PASS (tick)
  • 38.17 Copying karaf logs - PASS (tick)

...

  • 57.1 Apply cell to environment - PASS (tick)
  • 57.2 Uninstalling ONOS package - PASS (tick)
  • 57.3 Installing ONOS package - PASS (tick)
  • 57.4 Set up ONOS secure SSH - PASS (tick)
  • 57.5 Checking ONOS service - PASS (tick)
  • 57.6 Starting ONOS CLI sessions - PASS (tick)
  • 57.7 Starting Mininet Topology - PASS (tick)
  • 57.8 Check whether the flow count is bigger than 74 - PASS (tick)
  • 57.9 Check whether all flow status are ADDED - PASS (tick)
  • 57.10 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 57.11 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 57.12 Verify full connectivity for [u'h1', u'h2'] with tag CASE57 - PASS (tick)
  • 57.13 Verify full connectivity for [u'h3', u'h4'] with tag CASE57 - PASS (tick)
  • 57.14 Stopping Mininet - PASS (tick)
  • 57.15 Copying karaf logs - PASS (tick)

Case 58: Bridging test between two untagged hosts with different vlan id, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 58.1 Apply cell to environment - PASS (tick)
  • 58.2 Uninstalling ONOS package - PASS (tick)
  • 58.3 Installing ONOS package - PASS (tick)
  • 58.4 Set up ONOS secure SSH - PASS (tick)
  • 58.5 Checking ONOS service - PASS (tick)
  • 58.6 Starting ONOS CLI sessions - PASS (tick)
  • 58.7 Starting Mininet Topology - PASS (tick)
  • 58.8 Check whether the flow count is bigger than 212 - PASS (tick)
  • 58.9 Check whether all flow status are ADDED - PASS (tick)
  • 58.10 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 58.11 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 58.12 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 58.13 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong.
  • 58.14 Verify full connectivity for [u'h1', u'h2'] with tag CASE58 - PASS (tick)
  • 58.15 Verify full connectivity for [u'h3', u'h4'] with tag CASE58 - PASS (tick)
  • 58.16 Stopping Mininet - PASS (tick)
  • 58.17 Copying karaf logs - PASS (tick)

...