Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Published from Jenkins build: https://jenkins.onosproject.org/job/SR-pipeline-master/158/

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric4/lastSuccessfulBuild/artifact/SRBridging_master_20-builds_graph.jpg", alt="SRBridging", style="width:525px;height:350px;border:0">

commit 257eb6d6bf2fe77d5e97f564b6f611927f03db3a 87a3f855a39aaa2f1409db85b7ee45e1616651dd (HEAD -] master, origin/master, origin/HEAD)
Author: Ray Milkey [ray@opennetworking.org]
AuthorDate: Tue Wed Jul 17 0918 10:4100:00 52 2018 -0700
Commit: Ray Milkey [ray@opennetworking.org]
CommitDate: Tue Wed Jul 17 2118 10:2800:41 52 2018 +0000
Bazel builds for additional drivers-0700

Sonar warning - don't check a value known to be null

Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR and 3 ONOS instances - PASS

...

  • 18.1 Apply cell to environment - PASS (tick)
  • 18.2 Uninstalling ONOS package - PASS (tick)
  • 18.3 Installing ONOS package - PASS (tick)
  • 18.4 Set up ONOS secure SSH - PASS (tick)
  • 18.5 Checking ONOS service - PASS (tick)
  • 18.6 Starting ONOS CLI sessions - PASS (tick)
  • 18.7 Starting Mininet Topology - PASS (tick)
  • 18.8 Check whether the flow count is bigger than 212 - PASS (tick)
  • 18.9 Check whether all flow status are ADDED - PASS (tick)
  • 18.10 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 18.11 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 18.12 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 18.13 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)
  • 18.14 Verify full connectivity for [u'h1', u'h2'] with tag CASE18 - PASS (tick)
  • 18.15 Verify full connectivity for [u'h3', u'h4'] with tag CASE18 - PASS (tick)
  • 18.16 Stopping Mininet - PASS (tick)
  • 18.17 Copying karaf logs - PASS (tick)

Case 25: Bridging test between two untagged hosts on vlan-native port, with single ToR and 3 ONOS instances -

...

PASS

  • 25.1 Apply cell to environment - PASS (tick)
  • 25.2 Uninstalling ONOS package - PASS (tick)
  • 25.3 Installing ONOS package - PASS (tick)
  • 25.4 Set up ONOS secure SSH - PASS (tick)
  • 25.5 Checking ONOS service - PASS (tick)
  • 25.6 Starting ONOS CLI sessions - PASS (tick)
  • 25.7 Starting Mininet Topology - PASS (tick)
  • 25.8 Check whether the flow count is bigger than 28 - FAIL (error)
  • Flow count looks wrong: False
  • PASS (tick)
  • 25.9 Check whether all flow status are ADDED - PASS (tick)
  • 25.10 Check whether the flow count of device of:0000000000000001 is bigger than 28 - FAIL (error)
    • Flow count looks wrong.
  • PASS (tick)
  • 25.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE25 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 25.12 Stopping Mininet - PASS (tick)
  • 25.13 Copying karaf logs - PASS (tick)

...

  • 46.1 Apply cell to environment - PASS (tick)
  • 46.2 Uninstalling ONOS package - PASS (tick)
  • 46.3 Installing ONOS package - PASS (tick)
  • 46.4 Set up ONOS secure SSH - PASS (tick)
  • 46.5 Checking ONOS service - PASS (tick)
  • 46.6 Starting ONOS CLI sessions - PASS (tick)
  • 46.7 Starting Mininet Topology - PASS (tick)
  • 46.8 Check whether the flow count is bigger than 74 - PASS (tick)
  • 46.9 Check whether all flow status are ADDED - PASS (tick)
  • 46.10 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 46.11 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 46.12 Verify full connectivity for [u'h1', u'h2'] with tag CASE46 - PASS (tick)
  • 46.13 Stopping Mininet - PASS (tick)
  • 46.14 Copying karaf logs - PASS (tick)

Case 47: Bridging test between untagged host and tagged host, with 2x2 leaf-spine topology and 3 ONOS instances -

...

PASS

  • 47.1 Apply cell to environment - PASS (tick)
  • 47.2 Uninstalling ONOS package - PASS (tick)
  • 47.3 Installing ONOS package - PASS (tick)
  • 47.4 Set up ONOS secure SSH - PASS (tick)
  • 47.5 Checking ONOS service - PASS (tick)
  • 47.6 Starting ONOS CLI sessions - PASS (tick)
  • 47.7 Starting Mininet Topology - PASS (tick)
  • 47.8 Check whether the flow count is bigger than 74 - FAIL (error)
  • Flow count looks wrong: False
  • PASS (tick)
  • 47.9 Check whether all flow status are ADDED - PASS (tick)
  • 47.10 Check whether the flow count of device of:0000000000000001 is bigger than 37 - FAIL (error)
    • Flow count looks wrong.
  • PASS (tick)
  • 47.11 Check whether the flow count of device of:0000000000000002 is bigger than 37 - FAIL (error)
  • Flow count looks wrong.
  • PASS (tick)
  • 47.12 Verify full connectivity for [u'h1', u'h2'] with tag CASE47 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 47.13 Verify full connectivity for [u'h3', u'h4'] with tag CASE47 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 47.14 Stopping Mininet - PASS (tick)
  • 47.15 Copying karaf logs - PASS (tick)

...