Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
HTML |
---|
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric3/lastSuccessfulBuild/artifact/SRDynamicConf_onos-1.12_20-builds_graph.jpg", alt="SRDynamicConf", style="width:525px;height:350px;border:0"> |
commit 8bb885308d0210fcc3812d758a9b35fc0d52a756 8fe5333a9fbd0b9d9fd48cb52056bf04991d9b3d (HEAD -] onos-1.12, origin/onos-1.12)
Author: Thomas Vachuska You Wang [tom@opennetworkingyou@opennetworking.org]
AuthorDate: Tue Wed Jul 17 18 11:5123:54 58 2018 -0700
Commit: Thomas Vachuska [tom@opennetworking.org]
CommitDate: Tue Jul 17 1324 18:2405:55 2018 -0700
Added RBAC for REST APIs.00 2018 +0000
Add authentication to post to FlowTest REST API
--
(cherry picked from commit e9487b0dc8cb96aa897b42a969fe6b5bac98b881)
Case 13: Changing port configuration from untagged 10 to tagged 10, with 2x2 leaf-spine topology and 3 ONOS instances - PASS
...
- 53.1 Apply cell to environment - PASS
- 53.2 Uninstalling ONOS package - PASS
- 53.3 Installing ONOS package - PASS
- 53.4 Set up ONOS secure SSH - PASS
- 53.5 Checking ONOS service - PASS
- 53.6 Starting ONOS CLI sessions - PASS
- 53.7 Starting Mininet Topology - PASS
- 53.8 Check whether the flow count is bigger than 104 - PASS
- 53.9 Check whether all flow status are ADDED - PASS
- 53.10 Verify full connectivity for [u'h3', u'h4'] with tag CASE53_Before - PASS
- 53.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE53_Before - PASS
- 53.12 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 53.13 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 53.14 Check whether the flow count is bigger than 104 - PASS
- 53.15 Check whether all flow status are ADDED - PASS
- 53.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE53_After - PASS
- 53.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE53_After - PASS
- 53.18 Stopping Mininet - PASS
- 53.19 Copying karaf logs - PASS
Case 63: Changing port configuration from untagged 10 to tagged 120 with native 110, with 2x2 leaf-spine topology and 3 ONOS instances -
...
FAIL
- 63.1 Apply cell to environment - PASS
- 63.2 Uninstalling ONOS package - PASS
- 63.3 Installing ONOS package - PASS
- 63.4 Set up ONOS secure SSH - PASS
- 63.5 Checking ONOS service - PASS
- 63.6 Starting ONOS CLI sessions - PASS
- 63.7 Starting Mininet Topology - PASS
- 63.8 Check whether the flow count is bigger than 104 - PASS
- 63.9 Check whether all flow status are ADDED - PASS
- 63.10 Verify full connectivity for [u'h3', u'h4'] with tag CASE63_Before - PASS
- 63.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE63_Before - PASS
- 63.12 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 63.13 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 63.14 Check whether the flow count is bigger than 104 - PASS
- 63.15 Check whether all flow status are ADDED - PASS FAIL
- Flow status is wrong!
- 63.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE63_After - PASS
- 63.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE63_After - PASS
- 63.18 Stopping Mininet - PASS
- 63.19 Copying karaf logs - PASS
...