Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
HTML |
---|
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric3/lastSuccessfulBuild/artifact/SRSwitchFailure_onos-2.2_20-builds_graph.jpg", alt="SRSwitchFailure", style="width:525px;height:350px;border:0"> |
commit d14355c0712d9392fe76b503f7de19b83ab941ac 55b0908b1b2da173d0a1866a66d428305062a164 (HEAD -] onos-2.2, origin/onos-2.2)
Author: Andrea Campanella pierventre [andrea@opennetworkingpier@opennetworking.org]
AuthorDate: Mon May 3 15:59:19 Fri Apr 9 14:32:11 2021 +0200
Commit: Andrea Campanella [andrea@opennetworkingPier Luigi Ventre [pier@opennetworking.org]
CommitDate: Wed May 19 11:03:52 Thu Jun 3 06:53:48 2021 +0000
[VOLSDFAB-405516][ONOSSDFAB-813817] Adding annotations to meter to allow passing of associated informationSeveral improvements to the GDP
Case 1: Switch Failure test with 2x2 Leaf-spine and 1 Onos -
...
PASS
- 1.1 Constructing test variables - PASS
- 1.2 Apply cell to environment - PASS
- 1.3 Uninstalling Atomix - PASS
- 1.4 Uninstalling ONOS package - PASS
- 1.5 Creating ONOS package - PASS
- 1.6 Installing Atomix - PASS
- 1.7 Installing ONOS package - PASS
- 1.8 Set up ONOS secure SSH - PASS
- 1.9 Checking ONOS service - PASS
- 1.10 Starting ONOS CLI sessions - PASS
- 1.11 Checking ONOS nodes - PASS
- 1.12 Checking ONOS applications - PASS
- 1.13 Set logging levels - PASS
- 1.14 Set ONOS configurations - PASS
- 1.15 Starting Mininet Topology - PASS
- 1.16 Check whether the flow count is >= 116 - PASS
- 1.17 Check whether all flow status are ADDED - PASS
- 1.18 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1 - FAIL
- IP connectivity failed
- PASS
- 1.19 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1 - PASS
- 1.20 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1 - PASS
- 1.21 Kill ['spine101'] - PASS
- 1.22 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_Failure - FAIL
- IP connectivity failed
- PASS
- 1.23 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_Failure - PASS
- 1.24 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_Failure - PASS
- 1.25 Recovering ['spine101'] - PASS
- 1.26 Check whether the flow count is >= 116 - PASS
- 1.27 Check whether all flow status are ADDED - PASS
- 1.28 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_Recovery - FAIL
- IP connectivity failed
- PASS
- 1.29 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_Recovery - PASS
- 1.30 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_Recovery - PASS
- 1.31 Stopping Mininet - PASS
- 1.32 Copying karaf logs - PASS
...
- 2.1 Apply cell to environment - PASS
- 2.2 Uninstalling Atomix - PASS
- 2.3 Uninstalling ONOS package - PASS
- 2.4 Creating ONOS package - PASS
- 2.5 Installing Atomix - PASS
- 2.6 Installing ONOS package - PASS
- 2.7 Set up ONOS secure SSH - PASS
- 2.8 Checking ONOS service - PASS
- 2.9 Starting ONOS CLI sessions - PASS
- 2.10 Checking ONOS nodes - PASS
- 2.11 Checking ONOS applications - PASS
- 2.12 Set logging levels - PASS
- 2.13 Set ONOS configurations - PASS
- 2.14 Starting Mininet Topology - PASS
- 2.15 Check whether the flow count is >= 350 - PASS
- 2.16 Check whether all flow status are ADDED - PASS
- 2.17 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2 - PASS
- 2.18 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2 - PASS
- 2.19 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2 - PASS
- 2.20 Kill ['spine101'] - PASS
- 2.21 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2_Failure - PASS
- 2.22 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_Failure - PASS
- 2.23 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_Failure - PASS
- 2.24 Recovering ['spine101'] - PASS
- 2.25 Check whether the flow count is >= 350 - PASS
- 2.26 Check whether all flow status are ADDED - PASS
- 2.27 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2_Recovery - PASS
- 2.28 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_Recovery - PASS
- 2.29 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_Recovery - PASS
- 2.30 Stopping Mininet - PASS
- 2.31 Copying karaf logs - PASS
Case 4: Switch Failure test with 2x2 Leaf-spine and 3 Onos -
...
PASS
- 4.1 Apply cell to environment - PASS
- 4.2 Uninstalling Atomix - PASS
- 4.3 Uninstalling ONOS package - PASS
- 4.4 Creating ONOS package - PASS
- 4.5 Installing Atomix - PASS
- 4.6 Installing ONOS package - PASS
- 4.7 Set up ONOS secure SSH - PASS
- 4.8 Checking ONOS service - PASS
- 4.9 Starting ONOS CLI sessions - PASS
- 4.10 Checking ONOS nodes - PASS
- 4.11 Checking ONOS applications - PASS
- 4.12 Set logging levels - PASS
- 4.13 Set ONOS configurations - PASS
- 4.14 Starting Mininet Topology - PASS
- 4.15 Check whether the flow count is >= 116 - PASS
- 4.16 Check whether all flow status are ADDED - PASS
- 4.17 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE4 - FAIL
- IP connectivity failed
- PASS
- 4.18 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE4 - PASS
- 4.19 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE4 - PASS
- 4.20 Kill ['spine101'] - PASS
- 4.21 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE4_Failure - FAIL IP connectivity failed
- PASS
- 4.22 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE4_Failure - PASS
- 4.23 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE4_Failure - PASS
- 4.24 Recovering ['spine101'] - PASS
- 4.25 Check whether the flow count is >= 116 - PASS
- 4.26 Check whether all flow status are ADDED - PASS
- 4.27 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE4_Recovery - FAIL IP connectivity failed
- PASS
- 4.28 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE4_Recovery - PASS
- 4.29 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE4_Recovery - PASS
- 4.30 Stopping Mininet - PASS
- 4.31 Copying karaf logs - PASS
Case 5: Switch Failure test with 4x4 Leaf-spine and 3 Onos -
...
FAIL
- 5.1 Apply cell to environment - PASS
- 5.2 Uninstalling Atomix - PASS
- 5.3 Uninstalling ONOS package - PASS
- 5.4 Creating ONOS package - PASS
- 5.5 Installing Atomix - PASS
- 5.6 Installing ONOS package - PASS
- 5.7 Set up ONOS secure SSH - PASS
- 5.8 Checking ONOS service - PASS
- 5.9 Starting ONOS CLI sessions - PASS
- 5.10 Checking ONOS nodes - PASS
- 5.11 Checking ONOS applications - PASS
- 5.12 Set logging levels - PASS
- 5.13 Set ONOS configurations - PASS
- 5.14 Starting Mininet Topology - PASS
- 5.15 Check whether the flow count is >= 350 - PASS
- 5.16 Check whether all flow status are ADDED - PASS
- 5.17 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE5 - PASS FAIL
- IP connectivity failed
- 5.18 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE5 - PASS
- 5.19 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE5 - PASS
- 5.20 Kill ['spine101'] - PASS
- 5.21 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE5_Failure - PASS FAIL
- IP connectivity failed
- 5.22 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE5_Failure - PASS
- 5.23 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE5_Failure - PASS
- 5.24 Recovering ['spine101'] - PASS FAIL
- Failed to recover switch?
- 5.25 Check whether the flow count is >= 350 - PASS
- 5.26 Check whether all flow status are ADDED - PASS FAIL
- Flow status is wrong!
- 5.27 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE5_Recovery - PASS FAIL
- IP connectivity failed
- 5.28 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE5_Recovery - PASS
- 5.29 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE5_Recovery - PASS
- 5.30 Stopping Mininet - PASS
- 5.31 Copying karaf logs - PASS