commit 22591604f64ba868bec2ff305c534f667d9058e2 375942a31f14dd27db811abb3be1d1c57c50f312 (HEAD -] onos-2.2, origin/onos-2.2)
Author: Daniel Park pierventre [danpier@opennetworking.park@sk.comorg]
AuthorDate: Tue Jun 29 1614:3704:56 42 2021 +09000200
Commit: Daniel Park pierventre [danpier@opennetworking.park@sk.comorg]
CommitDate: Tue Jun 29 16:37:56 2021 +0900
Fix to preserve the old peer router MAC when a router is updated.Thu Jul 1 19:28:01 2021 +0200

[SDFAB-271] Change the default max inbound metadata size for grpc channels

Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR, ovs switches and 3 ONOS instances - PASS

...

  • 5.1 Constructing test variables - PASS (tick)
  • 5.2 Apply cell to environment - PASS (tick)
  • 5.3 Uninstalling Atomix - PASS (tick)
  • 5.4 Uninstalling ONOS package - PASS (tick)
  • 5.5 Creating ONOS package - PASS (tick)
  • 5.6 Installing Atomix - PASS (tick)
  • 5.7 Installing ONOS package - PASS (tick)
  • 5.8 Set up ONOS secure SSH - PASS (tick)
  • 5.9 Checking ONOS service - PASS (tick)
  • 5.10 Starting ONOS CLI sessions - PASS (tick)
  • 5.11 Checking ONOS nodes - PASS (tick)
  • 5.12 Checking ONOS applications - PASS (tick)
  • 5.13 Set logging levels - PASS (tick)
  • 5.14 Set ONOS configurations - PASS (tick)
  • 5.15 Starting Mininet Topology - PASS (tick)
  • 5.16 Check whether the flow count is >= 28 - PASS (tick)
  • 5.17 Check whether all flow status are ADDED - PASS (tick)
  • 5.18 Check whether the flow count of device of:0000000000000001 >= than 28 - PASS (tick)
  • 5.19 Check number of topology elements - PASS (tick)
  • 5.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE5 - PASS (tick)
  • 5.21 Stopping Mininet - PASS (tick)
  • 5.22 Copying karaf logs - PASS (tick)

Case 6: Bridging test between two untagged hosts on vlan-untagged port, with dual-homed ToR, ovs switches and 3 ONOS instances - PASS

  • 6.1 Apply cell to environment - PASS (tick)
  • 6.2 Uninstalling Atomix - PASS (tick)
  • 6.3 Uninstalling ONOS package - PASS (tick)
  • 6.4 Installing Atomix - PASS (tick)
  • 6.5 Installing ONOS package - PASS (tick)
  • 6.6 Set up ONOS secure SSH - PASS (tick)
  • 6.7 Checking ONOS service - PASS (tick)
  • 6.8 Starting ONOS CLI sessions - PASS (tick)
  • 6.9 Checking ONOS nodes - PASS (tick)
  • 6.10 Checking ONOS applications - PASS (tick)
  • 6.11 Set logging levels - PASS (tick)
  • 6.12 Set ONOS configurations - PASS (tick)
  • 6.13 Starting Mininet Topology - PASS (tick)
  • 6.14 Check whether the flow count is >= 74 - PASS (tick)
  • 6.15 Check whether all flow status are ADDED - PASS (tick)
  • 6.16 Check whether the flow count of device of:0000000000000001 >= than 37 - PASS (tick)
  • 6.17 Check whether the flow count of device of:0000000000000002 >= than 37 - PASS (tick)
  • 6.18 Check number of topology elements - PASS (tick)
  • 6.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE6 - PASS (tick)
  • 6.20 Stopping Mininet - PASS (tick)
  • 6.21 Copying karaf logs - PASS (tick)

Case 7: Bridging test between two untagged hosts on vlan-untagged port, with 2x2 leaf-spine topology, ovs switches and 3 ONOS instances - PASS

  • 7.1 Apply cell to environment - PASS (tick)
  • 7.2 Uninstalling Atomix - PASS (tick)
  • 7.3 Uninstalling ONOS package - PASS (tick)
  • 7.4 Installing Atomix - PASS (tick)
  • 7.5 Installing ONOS package - PASS (tick)
  • 7.6 Set up ONOS secure SSH - PASS (tick)
  • 7.7 Checking ONOS service - PASS (tick)
  • 7.8 Starting ONOS CLI sessions - PASS (tick)
  • 7.9 Checking ONOS nodes - PASS (tick)
  • 7.10 Checking ONOS applications - PASS (tick)
  • 7.11 Set logging levels - PASS (tick)
  • 7.12 Set ONOS configurations - PASS (tick)
  • 7.13 Starting Mininet Topology - PASS (tick)
  • 7.14 Check whether the flow count is >= 74 - PASS (tick)
  • 7.15 Check whether all flow status are ADDED - PASS (tick)
  • 7.16 Check whether the flow count of device of:0000000000000001 >= than 37 - PASS (tick)
  • 7.17 Check whether the flow count of device of:0000000000000002 >= than 37 - PASS (tick)
  • 7.18 Check number of topology elements - PASS (tick)
  • 7.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE7 - PASS (tick)
  • 7.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE7 - PASS (tick)
  • 7.21 Stopping Mininet - PASS (tick)
  • 7.22 Copying karaf logs - PASS (tick)

Case 8: Bridging test between two untagged hosts on vlan-untagged port, with 2x4 dual-homed leaf-spine topology, ovs switches and 3 ONOS instances - FAIL

  • 8.1 Apply cell to environment - PASS (tick)
  • 8.2 Uninstalling Atomix - PASS (tick)
  • 8.3 Uninstalling ONOS package - PASS (tick)
  • 8.4 Installing Atomix - PASS (tick)
  • 8.5 Installing ONOS package - PASS (tick)
  • 8.6 Set up ONOS secure SSH - PASS (tick)
  • 8.7 Checking ONOS service - PASS (tick)
  • 8.8 Starting ONOS CLI sessions - PASS (tick)
  • 8.9 Checking ONOS nodes - PASS (tick)
  • 8.10 Checking ONOS applications - PASS (tick)
  • 8.11 Set logging levels - PASS (tick)
  • 8.12 Set ONOS configurations - PASS (tick)
  • 8.13 Starting Mininet Topology - PASS (tick)
  • 8.14 Check whether the flow count is >= 212 - PASS (tick)
  • 8.15 Check whether all flow status are ADDED - PASS (tick)
  • 8.16 Check whether the flow count of device of:0000000000000001 >= than 53 - PASS (tick)
  • 8.17 Check whether the flow count of device of:0000000000000002 >= than 53 - PASS (tick)
  • 8.18 Check whether the flow count of device of:0000000000000003 >= than 53 - PASS (tick)
  • 8.19 Check whether the flow count of device of:0000000000000004 >= than 53 - PASS (tick)
  • 8.20 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
    • ONOS sees 6 devices (6 expected) and 36 links (38 expected) and 3 controllers (3 expected) and 1 SCCs (1 expected)
  • 8.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE8 - PASS (tick)
  • 8.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE8 - PASS (tick)
  • 8.23 Stopping Mininet - PASS (tick)
  • 8.24 Copying karaf logs - PASS (tick)

Case 15: Bridging test between two tagged hosts, with single ToR, ovs switches and 3 ONOS instances - PASS

  • 15.1 Apply cell to environment - PASS (tick)
  • 15.2 Uninstalling Atomix - PASS (tick)
  • 15.3 Uninstalling ONOS package - PASS (tick)
  • 15.4 Installing Atomix - PASS (tick)
  • 15.5 Installing ONOS package - PASS (tick)
  • 15.6 Set up ONOS secure SSH - PASS (tick)
  • 15.7 Checking ONOS service - PASS (tick)
  • 15.8 Starting ONOS CLI sessions - PASS (tick)
  • 15.9 Checking ONOS nodes - PASS (tick)
  • 15.10 Checking ONOS applications - PASS (tick)
  • 15.11 Set logging levels - PASS (tick)
  • 15.12 Set ONOS configurations - PASS (tick)
  • 15.13 Starting Mininet Topology - PASS (tick)
  • 15.14 Check whether the flow count is >= 28 - PASS (tick)
  • 15.15 Check whether all flow status are ADDED - PASS (tick)
  • 15.16 Check whether the flow count of device of:0000000000000001 >= than 28 - PASS (tick)
  • 15.17 Check number of topology elements - PASS (tick)
  • 15.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE15 - PASS (tick)
  • 15.19 Stopping Mininet - PASS (tick)
  • 15.20 Copying karaf logs - PASS (tick)

Case 16: Bridging test between two tagged hosts, with dual-homed ToR, ovs switches and 3 ONOS instances - PASS

  • 16.1 Apply cell to environment - PASS (tick)
  • 16.2 Uninstalling Atomix - PASS (tick)
  • 16.3 Uninstalling ONOS package - PASS (tick)
  • 16.4 Installing Atomix - PASS (tick)
  • 16.5 Installing ONOS package - PASS (tick)
  • 16.6 Set up ONOS secure SSH - PASS (tick)
  • 16.7 Checking ONOS service - PASS (tick)
  • 16.8 Starting ONOS CLI sessions - PASS (tick)
  • 16.9 Checking ONOS nodes - PASS (tick)
  • 16.10 Checking ONOS applications - PASS (tick)
  • 16.11 Set logging levels - PASS (tick)
  • 16.12 Set ONOS configurations - PASS (tick)
  • 16.13 Starting Mininet Topology - PASS (tick)
  • 16.14 Check whether the flow count is >= 74 - PASS (tick)
  • 16.15 Check whether all flow status are ADDED - PASS (tick)
  • 16.16 Check whether the flow count of device of:0000000000000001 >= than 37 - PASS (tick)
  • 16.17 Check whether the flow count of device of:0000000000000002 >= than 37 - PASS (tick)
  • 16.18 Check number of topology elements - PASS (tick)
  • 16.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE16 - PASS (tick)
  • 16.20 Stopping Mininet - PASS (tick)
  • 16.21 Copying karaf logs - PASS (tick)

Case 17: Bridging test between two tagged hosts, with 2x2 leaf-spine topology, ovs switches and 3 ONOS instances - FAIL

  • 17.1 Apply cell to environment - PASS (tick)
  • 17.2 Uninstalling Atomix - PASS (tick)
  • 17.3 Uninstalling ONOS package - PASS (tick)
  • 17.4 Installing Atomix - PASS (tick)
  • 17.5 Installing ONOS package - PASS (tick)
  • 17.6 Set up ONOS secure SSH - PASS (tick)
  • 17.7 Checking ONOS service - PASS (tick)
  • 17.8 Starting ONOS CLI sessions - PASS (tick)
  • 17.9 Checking ONOS nodes - PASS (tick)
  • 17.10 Checking ONOS applications - PASS (tick)
  • 17.11 Set logging levels - PASS (tick)
  • 17.12 Set ONOS configurations - PASS (tick)
  • 17.13 Starting Mininet Topology - PASS (tick)
  • 17.14 Check whether the flow count is >= 74 - FAIL (error)
    • Flow count looks wrong; found 72, expecting at least 74
  • 17.15 Check whether all flow status are ADDED - PASS (tick)
  • 17.16 Check whether the flow count of device of:0000000000000001 >= than 37 - FAIL (error)
    • Flow count looks wrong: 18
  • 17.17 Check whether the flow count of device of:0000000000000002 >= than 37 - FAIL (error)
    • Flow count looks wrong: 18
  • 17.18 Check number of topology elements - PASS (tick)
  • 17.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE17 - FAIL (error)
    • IP connectivity failed
  • 17.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE17 - FAIL (error)
    • IP connectivity failed
  • 17.21 Stopping Mininet - PASS (tick)
  • 17.22 Copying karaf logs - PASS (tick)

Case 18: Bridging test between two tagged hosts, with 2x4 dual-homed leaf-spine topology, ovs switches and 3 ONOS instances - FAIL

  • 18.1 Apply cell to environment - PASS (tick)
  • 18.2 Uninstalling Atomix - PASS (tick)
  • 18.3 Uninstalling ONOS package - PASS (tick)
  • 18.4 Installing Atomix - PASS (tick)
  • 18.5 Installing ONOS package - PASS (tick)
  • 18.6 Set up ONOS secure SSH - PASS (tick)
  • 18.7 Checking ONOS service - PASS (tick)
  • 18.8 Starting ONOS CLI sessions - PASS (tick)
  • 18.9 Checking ONOS nodes - PASS (tick)
  • 18.10 Checking ONOS applications - PASS (tick)
  • 18.11 Set logging levels - PASS (tick)
  • 18.12 Set ONOS configurations - PASS (tick)
  • 18.13 Starting Mininet Topology - PASS (tick)
  • 18.14 Check whether the flow count is >= 212 - PASS (tick)
  • 18.15 Check whether all flow status are ADDED - PASS (tick)
  • 18.16 Check whether the flow count of device of:0000000000000001 >= than 53 - PASS (tick)
  • 18.17 Check whether the flow count of device of:0000000000000002 >= than 53 - PASS (tick)
  • 18.18 Check whether the flow count of device of:0000000000000003 >= than 53 - PASS (tick)
  • 18.19 Check whether the flow count of device of:0000000000000004 >= than 53 - PASS (tick)
  • 18.20 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
    • ONOS sees 6 devices (6 expected) and 36 links (38 expected) and 3 controllers (3 expected) and 1 SCCs (1 expected)
  • 18.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE18 - PASS (tick)
  • 18.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE18 - PASS (tick)
  • 18.23 Stopping Mininet - PASS (tick)
  • 18.24 Copying karaf logs - PASS (tick)

Case 25: Bridging test between two untagged hosts on vlan-native port, with single ToR, ovs switches and 3 ONOS instances - PASS

  • 25.1 Apply cell to environment - PASS (tick)
  • 25.2 Uninstalling Atomix - PASS (tick)
  • 25.3 Uninstalling ONOS package - PASS (tick)
  • 25.4 Installing Atomix - PASS (tick)
  • 25.5 Installing ONOS package - PASS (tick)
  • 25.6 Set up ONOS secure SSH - PASS (tick)
  • 25.7 Checking ONOS service - PASS (tick)
  • 25.8 Starting ONOS CLI sessions - PASS (tick)
  • 25.9 Checking ONOS nodes - PASS (tick)
  • 25.10 Checking ONOS applications - PASS (tick)
  • 25.11 Set logging levels - PASS (tick)
  • 25.12 Set ONOS configurations - PASS (tick)
  • 25.13 Starting Mininet Topology - PASS (tick)
  • 25.14 Check whether the flow count is >= 28 - PASS (tick)
  • 25.15 Check whether all flow status are ADDED - PASS (tick)
  • 25.16 Check whether the flow count of device of:0000000000000001 >= than 28 - PASS (tick)
  • 25.17 Check number of topology elements - PASS (tick)
  • 25.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE25 - PASS (tick)
  • 25.19 Stopping Mininet - PASS (tick)
  • 25.20 Copying karaf logs - PASS (tick)

Case 26: Bridging test between two untagged hosts on vlan-native port, with dual-homed ToR, ovs switches and 3 ONOS instances - FAIL

  • 26.1 Apply cell to environment - PASS (tick)
  • 26.2 Uninstalling Atomix - PASS (tick)
  • 26.3 Uninstalling ONOS package - PASS (tick)
  • 26.4 Installing Atomix - PASS (tick)
  • 26.5 Installing ONOS package - PASS (tick)
  • 26.6 Set up ONOS secure SSH - PASS (tick)
  • 26.7 Checking ONOS service - PASS (tick)
  • 26.8 Starting ONOS CLI sessions - PASS (tick)
  • 26.9 Checking ONOS nodes - PASS (tick)
  • 26.10 Checking ONOS applications - PASS (tick)
  • 26.11 Set logging levels - PASS (tick)
  • 26.12 Set ONOS configurations - PASS (tick)
  • 26.13 Starting Mininet Topology - PASS (tick)
  • 26.14 Check whether the flow count is >= 74 - FAIL (error)
    • Flow count looks wrong; found 36, expecting at least 74
  • 26.15 Check whether all flow status are ADDED - PASS (tick)
  • 26.16 Check whether the flow count of device of:0000000000000001 >= than 37 - FAIL (error)
    • Flow count looks wrong: 18
  • 26.17 Check whether the flow count of device of:0000000000000002 >= than 37 - FAIL (error)
    • Flow count looks wrong: 18
  • 26.18 Check number of topology elements - PASS (tick)
  • 26.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE26 - FAIL (error)
    • IP connectivity failed
  • 26.20 Stopping Mininet - PASS (tick)
  • 26.21 Copying karaf logs - PASS (tick)

Case 27: Bridging test between two untagged hosts on vlan-native port, with 2x2 leaf-spine topology, ovs switches and 3 ONOS instances - PASS

  • 27.1 Apply cell to environment - PASS (tick)
  • 27.2 Uninstalling Atomix - PASS (tick)
  • 27.3 Uninstalling ONOS package - PASS (tick)
  • 27.4 Installing Atomix - PASS (tick)
  • 27.5 Installing ONOS package - PASS (tick)
  • 27.6 Set up ONOS secure SSH - PASS (tick)
  • 27.7 Checking ONOS service - PASS (tick)
  • 27.8 Starting ONOS CLI sessions - PASS (tick)
  • 27.9 Checking ONOS nodes - PASS (tick)
  • 27.10 Checking ONOS applications - PASS (tick)
  • 27.11 Set logging levels - PASS (tick)
  • 27.12 Set ONOS configurations - PASS (tick)
  • 27.13 Starting Mininet Topology - PASS (tick)
  • 27.14 Check whether the flow count is >= 74 - PASS (tick)
  • 27.15 Check whether all flow status are ADDED - PASS (tick)
  • 27.16 Check whether the flow count of device of:0000000000000001 >= than 37 - PASS (tick)
  • 27.17 Check whether the flow count of device of:0000000000000002 >= than 37 - PASS (tick)
  • 27.18 Check number of topology elements - PASS (tick)
  • 27.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE27 - PASS (tick)
  • 27.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE27 - PASS (tick)
  • 27.21 Stopping Mininet - PASS (tick)
  • 27.22 Copying karaf logs - PASS (tick)

Case 28: Bridging test between two untagged hosts on vlan-native port, with 2x4 dual-homed leaf-spine topology, ovs switches and 3 ONOS instances - FAIL

  • 28.1 Apply cell to environment - PASS (tick)
  • 28.2 Uninstalling Atomix - PASS (tick)
  • 28.3 Uninstalling ONOS package - PASS (tick)
  • 28.4 Installing Atomix - PASS (tick)
  • 28.5 Installing ONOS package - PASS (tick)
  • 28.6 Set up ONOS secure SSH - PASS (tick)
  • 28.7 Checking ONOS service - PASS (tick)
  • 28.8 Starting ONOS CLI sessions - PASS (tick)
  • 28.9 Checking ONOS nodes - PASS (tick)
  • 28.10 Checking ONOS applications - PASS (tick)
  • 28.11 Set logging levels - PASS (tick)
  • 28.12 Set ONOS configurations - PASS (tick)
  • 28.13 Starting Mininet Topology - PASS (tick)
  • 28.14 Check whether the flow count is >= 212 - FAIL (error)
    • Flow count looks wrong; found 108, expecting at least 212
  • 28.15 Check whether all flow status are ADDED - PASS (tick)
  • 28.16 Check whether the flow count of device of:0000000000000001 >= than 53 - FAIL (error)
    • Flow count looks wrong: 18
  • 28.17 Check whether the flow count of device of:0000000000000002 >= than 53 - FAIL (error)
    • Flow count looks wrong: 18
  • 28.18 Check whether the flow count of device of:0000000000000003 >= than 53 - FAIL (error)
    • Flow count looks wrong: 18
  • 28.19 Check whether the flow count of device of:0000000000000004 >= than 53 - FAIL (error)
    • Flow count looks wrong: 18
  • 28.20 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
    • ONOS sees 6 devices (6 expected) and 36 links (38 expected) and 3 controllers (3 expected) and 1 SCCs (1 expected)
  • 28.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE28 - FAIL (error)
    • IP connectivity failed
  • 28.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE28 - FAIL (error)
    • IP connectivity failed
  • 28.23 Stopping Mininet - PASS (tick)
  • 28.24 Copying karaf logs - PASS (tick)

Case 35: Bridging test between two untagged hosts, one on vlan-untagged port and the other on vlan-native port, with single ToR, ovs switches and 3 ONOS instances - PASS

  • 35.1 Apply cell to environment - PASS (tick)
  • 35.2 Uninstalling Atomix - PASS (tick)
  • 35.3 Uninstalling ONOS package - PASS (tick)
  • 35.4 Installing Atomix - PASS (tick)
  • 35.5 Installing ONOS package - PASS (tick)
  • 35.6 .8 Set up ONOS secure SSH - PASS (tick)
  • 35 5.7 9 Checking ONOS service - PASS (tick)
  • 35 5.8 10 Starting ONOS CLI sessions - PASS (tick)
  • 35 5.9 11 Checking ONOS nodes - PASS (tick)
  • 35 5.10 12 Checking ONOS applications - PASS (tick)
  • 35 5.11 13 Set logging levels - PASS (tick)
  • 35 5.12 14 Set ONOS configurations - PASS (tick)
  • 35 5.13 15 Starting Mininet Topology - PASS (tick)
  • 35 5.14 16 Check whether the flow count is >= 28 - PASS (tick)
  • 35 5.15 17 Check whether all flow status are ADDED - PASS (tick)
  • 35 5.16 18 Check whether the flow count of device of:0000000000000001 >= than 28 - PASS (tick)
  • 35 5.17 19 Check number of topology elements - PASS (tick)
  • 35 5.18 20 Verify full connectivity for [u'h1', u'h2'] with tag CASE35 CASE5 - PASS (tick)
  • 35 5.19 21 Stopping Mininet - PASS (tick)
  • 35 5.20 22 Copying karaf logs - PASS (tick)

Case

...

6: Bridging test between two untagged hosts

...

on vlan-untagged

...

port, with dual-homed ToR, ovs switches and 3 ONOS instances - PASS

  • 36 6.1 Apply cell to environment - PASS (tick)
  • 36 6.2 Uninstalling Atomix - PASS (tick)
  • 36 6.3 Uninstalling ONOS package - PASS (tick)
  • 36 6.4 Installing Atomix - PASS (tick)
  • 36 6.5 Installing ONOS package - PASS (tick)
  • 36 6.6 Set up ONOS secure SSH - PASS (tick)
  • 36 6.7 Checking ONOS service - PASS (tick)
  • 36 6.8 Starting ONOS CLI sessions - PASS (tick)
  • 36 6.9 Checking ONOS nodes - PASS (tick)
  • 36 6.10 Checking ONOS applications - PASS (tick)
  • 36 6.11 Set logging levels - PASS (tick)
  • 36 6.12 Set ONOS configurations - PASS (tick)
  • 36 6.13 Starting Mininet Topology - PASS (tick)
  • 36 6.14 Check whether the flow count is >= 74 - PASS (tick)
  • 36 6.15 Check whether all flow status are ADDED - PASS (tick)
  • 36 6.16 Check whether the flow count of device of:0000000000000001 >= than 37 - PASS (tick)
  • 36 6.17 Check whether the flow count of device of:0000000000000002 >= than 37 - PASS (tick)
  • 36 6.18 Check number of topology elements - PASS (tick)
  • 36 6.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE36 CASE6 - PASS (tick)
  • 36 6.20 Stopping Mininet - PASS (tick)
  • 36 6.21 Copying karaf logs - PASS (tick)

Case

...

7: Bridging test between two untagged hosts

...

on vlan-untagged

...

port, with 2x2 leaf-spine topology, ovs switches and 3 ONOS instances -

...

PASS

  • 37 7.1 Apply cell to environment - PASS (tick)
  • 37 7.2 Uninstalling Atomix - PASS (tick)
  • 37 7.3 Uninstalling ONOS package - PASS (tick)
  • 37 7.4 Installing Atomix - PASS (tick)
  • 37 7.5 Installing ONOS package - PASS (tick)
  • 37 7.6 Set up ONOS secure SSH - PASS (tick)
  • 37 7.7 Checking ONOS service - PASS (tick)
  • 37 7.8 Starting ONOS CLI sessions - PASS (tick)
  • 37 7.9 Checking ONOS nodes - PASS (tick)
  • 37 7.10 Checking ONOS applications - PASS (tick)
  • 37 7.11 Set logging levels - PASS (tick)
  • 37 7.12 Set ONOS configurations - PASS (tick)
  • 37 7.13 Starting Mininet Topology - PASS (tick)
  • 37 7.14 Check whether the flow count is >= 74 - PASS (tick)
  • 37 7.15 Check whether all flow status are ADDED - PASS (tick)
  • 37 7.16 Check whether the flow count of device of:0000000000000001 >= than 37 - FAIL (error)
    • Flow count looks wrong: 18
  • PASS (tick)
  • 7 37.17 Check whether the flow count of device of:0000000000000002 >= than 37 - PASS (tick)
  • 37 7.18 Check number of topology elements - PASS (tick)
  • 37 7.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE37 CASE7 - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 7 37.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE37 CASE7 - PASS (tick)
  • 37 7.21 Stopping Mininet - PASS (tick)
  • 37 7.22 Copying karaf logs - PASS (tick)

Case

...

8: Bridging test between two untagged hosts

...

on vlan-untagged

...

port, with 2x4 dual-homed leaf-spine topology, ovs switches and 3 ONOS instances - FAIL

  • 38 8.1 Apply cell to environment - PASS (tick)
  • 38 8.2 Uninstalling Atomix - PASS (tick)
  • 38 8.3 Uninstalling ONOS package - PASS (tick)
  • 38 8.4 Installing Atomix - PASS (tick)
  • 38 8.5 Installing ONOS package - PASS (tick)
  • 38 8.6 Set up ONOS secure SSH - PASS (tick)
  • 38 8.7 Checking ONOS service - PASS (tick)
  • 38 8.8 Starting ONOS CLI sessions - PASS (tick)
  • 38 8.9 Checking ONOS nodes - PASS (tick)
  • 38 8.10 Checking ONOS applications - PASS (tick)
  • 38 8.11 Set logging levels - PASS (tick)
  • 38 8.12 Set ONOS configurations - PASS (tick)
  • 38 8.13 Starting Mininet Topology - PASS (tick)
  • 38 8.14 Check whether the flow count is >= 212 - FAIL (error)
    • Flow count looks wrong; found 108, expecting at least 212
  • 38 8.15 Check whether all flow status are ADDED - PASS (tick)
  • 38 8.16 Check whether the flow count of device of:0000000000000001 >= than 53 - FAIL (error)
    • Flow count looks wrong: 18
  • 38 8.17 Check whether the flow count of device of:0000000000000002 >= than 53 - FAIL (error)
    • Flow count looks wrong: 18
  • 38 8.18 Check whether the flow count of device of:0000000000000003 >= than 53 - FAIL (error)
    • Flow count looks wrong: 18
  • 38 8.19 Check whether the flow count of device of:0000000000000004 >= than 53 - FAIL (error)
    • Flow count looks wrong: 18
  • 38 8.20 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
    • ONOS sees 6 devices (6 expected) and 36 links (38 expected) and 3 controllers (3 expected) and 1 SCCs (1 expected)
  • 38 8.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE38 CASE8 - FAIL (error)
    • IP connectivity failed
  • 38 8.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE38 CASE8 - FAIL (error)
    • IP connectivity failed
  • 38 8.23 Stopping Mininet - PASS (tick)
  • 38 8.24 Copying karaf logs - PASS (tick)

Case

...

15: Bridging test between

...

two tagged

...

hosts, with single ToR, ovs switches and 3 ONOS instances -

...

PASS

  • 45 15.1 Apply cell to environment - PASS (tick)
  • 45 15.2 Uninstalling Atomix - PASS (tick)
  • 45 15.3 Uninstalling ONOS package - PASS (tick)
  • 45 15.4 Installing Atomix - PASS (tick)
  • 45 15.5 Installing ONOS package - PASS (tick)
  • 45 15.6 Set up ONOS secure SSH - PASS (tick)
  • 45 15.7 Checking ONOS service - PASS (tick)
  • 45 15.8 Starting ONOS CLI sessions - PASS (tick)
  • 45 15.9 Checking ONOS nodes - PASS (tick)
  • 45 15.10 Checking ONOS applications - PASS (tick)
  • 45 15.11 Set logging levels - PASS (tick)
  • 45 15.12 Set ONOS configurations - PASS (tick)
  • 45 15.13 Starting Mininet Topology - PASS (tick)
  • 45 15.14 Check whether the flow count is >= 28 - FAIL (error)
    • Flow count looks wrong; found 17, expecting at least 28
  • PASS (tick)
  • 15 45.15 Check whether all flow status are ADDED - PASS (tick)
  • 45 15.16 Check whether the flow count of device of:0000000000000001 >= than 28 - FAIL (error)
    • Flow count looks wrong: 17
  • PASS (tick)
  • 15 45.17 Check number of topology elements - PASS (tick)
  • 45 15.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE45 CASE15 - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 15 45.19 Stopping Mininet - PASS (tick)
  • 45 15.20 Copying karaf logs - PASS (tick)

Case

...

16: Bridging test between

...

two tagged

...

hosts, with dual-homed ToR, ovs switches and 3 ONOS instances -

...

FAIL

  • 46 16.1 Apply cell to environment - PASS (tick)
  • 46 16.2 Uninstalling Atomix - PASS (tick)
  • 46 16.3 Uninstalling ONOS package - PASS (tick)
  • 46 16.4 Installing Atomix - PASS (tick)
  • 46 16.5 Installing ONOS package - PASS (tick)
  • 46 16.6 Set up ONOS secure SSH - PASS (tick)
  • 46 16.7 Checking ONOS service - PASS (tick)
  • 46 16.8 Starting ONOS CLI sessions - PASS (tick)
  • 46 16.9 Checking ONOS nodes - PASS (tick)
  • 46 16.10 Checking ONOS applications - PASS (tick)
  • 46 16.11 Set logging levels - PASS (tick)
  • 46 16.12 Set ONOS configurations - PASS (tick)
  • 46 16.13 Starting Mininet Topology - PASS (tick)
  • 46 16.14 Check whether the flow count is >= 74 - PASS (tick)FAIL (error)
    • Flow count looks wrong; found 36, expecting at least 74
  • 16 46.15 Check whether all flow status are ADDED - PASS (tick)
  • 46 16.16 Check whether the flow count of device of:0000000000000001 >= than 37 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 18
  • 16 46.17 Check whether the flow count of device of:0000000000000002 >= than 37 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 18
  • 16 46.18 Check number of topology elements - PASS (tick)
  • 46 16.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE46 - PASS (tick)CASE16 - FAIL (error)
    • IP connectivity failed
  • 16 46.20 Stopping Mininet - PASS (tick)
  • 46 16.21 Copying karaf logs - PASS (tick)

Case

...

17: Bridging test between

...

two tagged

...

hosts, with 2x2 leaf-spine topology, ovs switches and 3 ONOS instances - FAIL

  • 47 17.1 Apply cell to environment - PASS (tick)
  • 47 17.2 Uninstalling Atomix - PASS (tick)
  • 47 17.3 Uninstalling ONOS package - PASS (tick)
  • 47 17.4 Installing Atomix - PASS (tick)
  • 47 17.5 Installing ONOS package - PASS (tick)
  • 47 17.6 Set up ONOS secure SSH - PASS (tick)
  • 47 17.7 Checking ONOS service - PASS (tick)
  • 47 17.8 Starting ONOS CLI sessions - PASS (tick)
  • 47 17.9 Checking ONOS nodes - PASS (tick)
  • 47 17.10 Checking ONOS applications - PASS (tick)
  • 47 17.11 Set logging levels - PASS (tick)
  • 47 17.12 Set ONOS configurations - PASS (tick)
  • 47 17.13 Starting Mininet Topology - PASS (tick)
  • 47 17.14 Check whether the flow count is >= 74 - PASS (tick)count is >= 74 - FAIL (error)
    • Flow count looks wrong; found 72, expecting at least 74
  • 17 47.15 Check whether all flow status are ADDED - PASS (tick)
  • 47 17.16 Check whether the flow count of device of:0000000000000001 >= than 37 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 18
  • 17 47.17 Check whether the flow count of device of:0000000000000002 >= than 37 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 18
  • 17 47.18 Check number of topology elements - PASS (tick)
  • 47 17.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE47 - PASS (tick)CASE17 - FAIL (error)
    • IP connectivity failed
  • 17 47.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE47 CASE17 - FAIL (error)
    • IP connectivity failed
  • 47 17.21 Stopping Mininet - PASS (tick)
  • 47 17.22 Copying karaf logs - PASS (tick)

Case

...

18: Bridging test between

...

two tagged

...

hosts, with 2x4 dual-homed leaf-spine topology, ovs switches and 3 ONOS instances - FAIL

  • 48 18.1 Apply cell to environment - PASS (tick)
  • 48 18.2 Uninstalling Atomix - PASS (tick)
  • 48 18.3 Uninstalling ONOS package - PASS (tick)
  • 48 18.4 Installing Atomix - PASS (tick)
  • 48 18.5 Installing ONOS package - PASS (tick)
  • 48 18.6 Set up ONOS secure SSH - PASS (tick)
  • 48 18.7 Checking ONOS service - PASS (tick)
  • 48 18.8 Starting ONOS CLI sessions - PASS (tick)
  • 48 18.9 Checking ONOS nodes - PASS (tick)
  • 48 18.10 Checking ONOS applications - PASS (tick)
  • 48 18.11 Set logging levels - PASS (tick)
  • 48 18.12 Set ONOS configurations - PASS (tick)
  • 48 18.13 Starting Mininet Topology - PASS (tick)
  • 48 18.14 Check whether the flow count is >= 212 - PASS (tick)FAIL (error)
    • Flow count looks wrong; found 102, expecting at least 212
  • 18 48.15 Check whether all flow status are ADDED - PASS (tick)
  • 48 18.16 Check whether the flow count of device of:0000000000000001 >= than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 17
  • 18 48.17 Check whether the flow count of device of:0000000000000002 >= than 53 - PASS (tick):0000000000000002 >= than 53 - FAIL (error)
    • Flow count looks wrong: 17
  • 18 48.18 Check whether the flow count of device of:0000000000000003 >= than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 17
  • 18 48.19 Check whether the flow count of device of:0000000000000004 >= than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 17
  • 18 48.20 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
    • ONOS sees 6 devices (6 expected) and 36 links (38 expected) and 3 controllers (3 expected) and 1 SCCs (1 expected)
  • 48 18.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE48 - PASS (tick)CASE18 - FAIL (error)
    • IP connectivity failed
  • 18 48.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE48 CASE18 - FAIL (error)
    • IP connectivity failed
  • 48 18.23 Stopping Mininet - PASS (tick)
  • 48 18.24 Copying karaf logs - PASS (tick)

Case

...

25: Bridging test between two untagged hosts

...

on vlan-native port, with single ToR, ovs switches and 3 ONOS instances - PASS

  • 55 25.1 Apply cell to environment - PASS (tick)
  • 55 25.2 Uninstalling Atomix - PASS (tick)
  • 55 25.3 Uninstalling ONOS package - PASS (tick)
  • 55 25.4 Installing Atomix - PASS (tick)
  • 55 25.5 Installing ONOS package - PASS (tick)
  • 55 25.6 Set up ONOS secure SSH - PASS (tick)
  • 55 25.7 Checking ONOS service - PASS (tick)
  • 55 25.8 Starting ONOS CLI sessions - PASS (tick)
  • 55 25.9 Checking ONOS nodes - PASS (tick)
  • 55 25.10 Checking ONOS applications - PASS (tick)
  • 55 25.11 Set logging levels - PASS (tick)
  • 55 25.12 Set ONOS configurations - PASS (tick)
  • 55 25.13 Starting Mininet Topology - PASS (tick)
  • 55 25.14 Check whether the flow count is >= 28 - PASS (tick)
  • 55 25.15 Check whether all flow status are ADDED - PASS (tick)
  • 55 25.16 Check whether the flow count of device of:0000000000000001 >= than 28 - PASS (tick)
  • 55 25.17 Check number of topology elements - PASS (tick)
  • 55 25.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE55 CASE25 - PASS (tick)
  • 55 25.19 Stopping Mininet - PASS (tick)
  • 55 25.20 Copying karaf logs - PASS (tick)

Case

...

26: Bridging test between two untagged hosts

...

on vlan-native port, with dual-homed ToR, ovs switches and 3 ONOS instances - FAIL

Case

...

26: Bridging test between two untagged hosts

...

on vlan-native port, with dual-homed ToR, ovs switches and 3 ONOS instances - FAIL

Case

...

26: Bridging test between two untagged hosts

...

on vlan-native port, with dual-homed ToR, ovs switches and 3 ONOS instances - FAIL

Case

...

26: Bridging test between two untagged hosts

...

on vlan-native port, with dual-homed ToR, ovs switches and 3 ONOS instances - FAIL