Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Published from Jenkins build: https://jenkins.onosproject.org/job/SR-pipeline-1.12/222/

...

  • 43.1 Apply cell to environment - PASS (tick)
  • 43.2 Uninstalling ONOS package - PASS (tick)
  • 43.3 Installing ONOS package - PASS (tick)
  • 43.4 Set up ONOS secure SSH - PASS (tick)
  • 43.5 Checking ONOS service - PASS (tick)
  • 43.6 Starting ONOS CLI sessions - PASS (tick)
  • 43.7 Starting Mininet Topology - PASS (tick)
  • 43.8 Check whether the flow count is bigger than 104 - PASS (tick)
  • 43.9 Check whether all flow status are ADDED - PASS (tick)
  • 43.10 Verify full connectivity for [u'h3', u'h4'] with tag CASE43_Before - PASS (tick)
  • 43.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE43_Before - PASS (tick)
  • 43.12 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 43.13 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 43.14 Check whether the flow count is bigger than 104 - PASS (tick)
  • 43.15 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 43.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE43_After - PASS (tick)
  • 43.17 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE43_After - PASS (tick)
  • 43.18 Stopping Mininet - PASS (tick)
  • 43.19 Copying karaf logs - PASS (tick)

Case 53: Changing port configuration from untagged 10 to tagged 20 with native 10, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 53.1 Apply cell to environment - PASS (tick)
  • 53.2 Uninstalling ONOS package - PASS (tick)
  • 53.3 Installing ONOS package - PASS (tick)
  • 53.4 Set up ONOS secure SSH - PASS (tick)
  • 53.5 Checking ONOS service - PASS (tick)
  • 53.6 Starting ONOS CLI sessions - PASS (tick)
  • 53.7 Starting Mininet Topology - PASS (tick)
  • 53.8 Check whether the flow count is bigger than 104 - PASS (tick)FAIL (error)
    • Flow count looks wrong: False
  • 53.9 Check whether all flow status are ADDED - PASS (tick)
  • 53.10 Verify full connectivity for [u'h3', u'h4'] with tag CASE53_Before - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 53.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE53_Before - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 53.12 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)FAIL (error)
    • Flow count looks wrong.
  • 53.13 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)FAIL (error)
    • Flow count looks wrong.
  • 53.14 Check whether the flow count is bigger than 104 - PASS (tick)FAIL (error)
    • Flow count looks wrong: False
  • 53.15 Check whether all flow status are ADDED - PASS (tick)
  • 53.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE53_After - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 53.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE53_After - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 53.18 Stopping Mininet - PASS (tick)
  • 53.19 Copying karaf logs - PASS (tick)

Case 63: Changing port configuration from untagged 10 to tagged 120 with native 110, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 63.1 Apply cell to environment - PASS (tick)
  • 63.2 Uninstalling ONOS package - PASS (tick)
  • 63.3 Installing ONOS package - PASS (tick)
  • 63.4 Set up ONOS secure SSH - PASS (tick)
  • 63.5 Checking ONOS service - PASS (tick)
  • 63.6 Starting ONOS CLI sessions - PASS (tick)
  • 63.7 Starting Mininet Topology - PASS (tick)
  • 63.8 Check whether the flow count is bigger than 104 - PASS (tick)
  • 63.9 Check whether all flow status are ADDED - PASS (tick)
  • 63.10 Verify full connectivity for [u'h3', u'h4'] with tag CASE63_Before - PASS (tick)
  • 63.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE63_Before - PASS (tick)
  • 63.12 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 63.13 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 63.14 Check whether the flow count is bigger than 104 - PASS (tick)
  • 63.15 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 63.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE63_After - PASS (tick)
  • 63.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE63_After - PASS (tick)
  • 63.18 Stopping Mininet - PASS (tick)
  • 63.19 Copying karaf logs - PASS (tick)

...