Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
- 143.1 Apply cell to environment - PASS
- 143.2 Uninstalling ONOS package - PASS
- 143.3 Installing ONOS package - PASS
- 143.4 Set up ONOS secure SSH - PASS
- 143.5 Checking ONOS service - PASS
- 143.6 Starting ONOS CLI sessions - PASS
- 143.7 Starting Mininet Topology - PASS
- 143.8 Check whether the flow count is bigger than 106 - PASS
- 143.9 Check whether all flow status are ADDED - PASS
- 143.10 Verify full connectivity for [u'h3', u'h4'] with tag CASE143_Before - PASS
- 143.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE143_Before - PASS
- 143.12 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 143.13 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 143.14 Check whether the flow count is bigger than 106 - PASS
- 143.15 Check whether all flow status are ADDED - PASS
- 143.16 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE143_After - PASS
- 143.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE143_After - PASS
- 143.18 Stopping Mininet - PASS
- 143.19 Copying karaf logs - PASS
Case 153: Changing port configuration from untagged 10 to tagged 120, with 2x2 leaf-spine topology and 3 ONOS instances -
...
FAIL
- 153.1 Apply cell to environment - PASS
- 153.2 Uninstalling ONOS package - PASS
- 153.3 Installing ONOS package - PASS
- 153.4 Set up ONOS secure SSH - PASS
- 153.5 Checking ONOS service - PASS
- 153.6 Starting ONOS CLI sessions - PASS
- 153.7 Starting Mininet Topology - PASS
- 153.8 Check whether the flow count is bigger than 106 - PASS
- 153.9 Check whether all flow status are ADDED - PASS
- 153.10 Verify full connectivity for [u'h3', u'h4'] with tag CASE153_Before - PASS FAIL
- IP connectivity failed
- 153.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE153_Before - PASS
- 153.12 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 153.13 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 153.14 Check whether the flow count is bigger than 106 - PASS
- 153.15 Check whether all flow status are ADDED - PASS
- 153.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE153_After - PASS
- 153.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE153_After - PASS
- 153.18 Stopping Mininet - PASS
- 153.19 Copying karaf logs - PASS
...