Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
HTML |
---|
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric3/lastSuccessfulBuild/artifact/SRBridging_onos-1.14_20-builds_graph.jpg", alt="SRBridging", style="width:525px;height:350px;border:0"> |
commit c6a21bc5666af5fd0c856e7a22f0bbc2b3e7d13e 4ec2c16489377b1699037bdcf5ca6c19e27b15cc (HEAD -] onos-1.14, origin/onos-1.14)
Author: Carmelo Cascone Charles Chan [carmelo@opennetworkingrascov@gmail.orgcom]
AuthorDate: Tue Sep 11 13:28:59 2018 -0700Nov 27 21:33:33 2018 +0800
Commit: Carmelo Cascone Charles Chan [carmelo@opennetworkingrascov@gmail.orgcom]
CommitDate: Wed Sep 12 05:02:44 2018 +0000
Convert default routes to two table entries in fabric.p4 pipelinerDec 19 15:15:58 2018 -0800
Address StackOverflow by offloading cache listener to a separate thread
Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR and 3 ONOS instances - PASS
...
- 7.1 Apply cell to environment - PASS
- 7.2 Uninstalling Atomix - PASS
- 7.3 Uninstalling ONOS package - PASS
- 7.4 Installing Atomix - PASS
- 7.5 Installing ONOS package - PASS
- 7.6 Set up ONOS secure SSH - PASS
- 7.7 Checking ONOS service - PASS
- 7.8 Starting ONOS CLI sessions - PASS
- 7.9 Checking ONOS nodes - PASS
- 7.10 Checking ONOS applications - PASS
- 7.11 Starting Mininet Topology - PASS
- 7.12 Check whether the flow count is bigger than 74 - PASS
- 7.13 Check whether all flow status are ADDED - PASS
- 7.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 7.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 7.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE7 - PASS
- 7.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE7 - PASS
- 7.18 Stopping Mininet - PASS
- 7.19 Copying karaf logs - PASS
Case 8: Bridging test between two untagged hosts on vlan-untagged port, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances -
...
FAIL
- 8.1 Apply cell to environment - PASS
- 8.2 Uninstalling Atomix - PASS
- 8.3 Uninstalling ONOS package - PASS
- 8.4 Installing Atomix - PASS
- 8.5 Installing ONOS package - PASS
- 8.6 Set up ONOS secure SSH - PASS
- 8.7 Checking ONOS service - PASS
- 8.8 Starting ONOS CLI sessions - PASS
- 8.9 Checking ONOS nodes - PASS
- 8.10 Checking ONOS applications - PASS
- 8.11 Starting Mininet Topology - PASS
- 8.12 Check whether the flow count is bigger than 212 - PASS FAIL
- Flow count looks wrong: False
- 8.13 Check whether all flow status are ADDED - PASS
- 8.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS FAIL
- Flow count looks wrong.
- 8.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS FAIL
- Flow count looks wrong.
- 8.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS FAIL
- Flow count looks wrong.
- 8.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS
- 8.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE8 - PASS FAIL
- IP connectivity failed
- 8.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE8 - PASS FAIL
- IP connectivity failed
- 8.20 Stopping Mininet - PASS
- 8.21 Copying karaf logs - PASS
...
- 67.1 Apply cell to environment - PASS
- 67.2 Uninstalling Atomix - PASS
- 67.3 Uninstalling ONOS package - PASS
- 67.4 Installing Atomix - PASS
- 67.5 Installing ONOS package - PASS
- 67.6 Set up ONOS secure SSH - PASS
- 67.7 Checking ONOS service - PASS
- 67.8 Starting ONOS CLI sessions - PASS
- 67.9 Checking ONOS nodes - PASS
- 67.10 Checking ONOS applications - PASS
- 67.11 Starting Mininet Topology - PASS
- 67.12 Check whether the flow count is bigger than 74 - PASS
- 67.13 Check whether all flow status are ADDED - PASS
- 67.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 67.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 67.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE67 - PASS
- 67.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE67 - PASS
- 67.18 Stopping Mininet - PASS
- 67.19 Copying karaf logs - PASS
Case 68: Bridging test between two tagged hosts with different vlan id, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances
...
- PASS
- 68.1 Apply cell to environment - PASS
- 68.2 Uninstalling Atomix - PASS
- 68.3 Uninstalling ONOS package - PASS
- 68.4 Installing Atomix - PASS
- 68.5 Installing ONOS package - PASS
- 68.6 Set up ONOS secure SSH - PASS
- 68.7 Checking ONOS service - PASS
- 68.8 Starting ONOS CLI sessions - PASS
- 68.9 Checking ONOS nodes - PASS
- 68.10 Checking ONOS applications - PASS
- 68.11 Starting Mininet Topology - PASS
- 68.12 Check whether the flow count is bigger than 212 - PASS
- 68.13 Check whether all flow status are ADDED - PASS
- 68.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 68.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 68.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS
- 68.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS
- 68.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE68 - PASS
- 68.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE68 - PASS
- 68.20 Stopping Mininet - PASS
- 68.21 Copying karaf logs - PASS
Case 75: Bridging test between untagged and tagged hosts with different vlan id, with single ToR and 3 ONOS instances - PASS
- 75.1 Apply cell to environment - PASS
- 75.2 Uninstalling Atomix - PASS
- 75.3 Uninstalling ONOS package - PASS
- 75.4 Installing Atomix - PASS
- 75.5 Installing ONOS package - PASS
- 75.6 Set up ONOS secure SSH - PASS
- 75.7 Checking ONOS service - PASS
- 75.8 Starting ONOS CLI sessions - PASS
- 75.9 Checking ONOS nodes - PASS
- 75.10 Checking ONOS applications - PASS
- 75.11 Starting Mininet Topology - PASS
- 75.12 Check whether the flow count is bigger than 28 - PASS
- 75.13 Check whether all flow status are ADDED - PASS
- 75.14 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS
- 75.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE75 - PASS
- 75.16 Stopping Mininet - PASS
- 75.17 Copying karaf logs - PASS
Case 76: Bridging test between untagged and tagged hosts with different vlan id, with dual-homed ToR and 3 ONOS instances - PASS
- 76.1 Apply cell to environment - PASS
- 76.2 Uninstalling Atomix - PASS
- 76.3 Uninstalling ONOS package - PASS
- 76.4 Installing Atomix - PASS
- 76.5 Installing ONOS package - PASS
- 76.6 Set up ONOS secure SSH - PASS
- 76.7 Checking ONOS service - PASS
- 76.8 Starting ONOS CLI sessions - PASS
- 76.9 Checking ONOS nodes - PASS
- 76.10 Checking ONOS applications - PASS
- 76.11 Starting Mininet Topology - PASS
- 76.12 Check whether the flow count is bigger than 74 - PASS
- 76.13 Check whether all flow status are ADDED - PASS
- 76.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 76.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 76.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE76 - PASS
- 76.17 Stopping Mininet - PASS
- 76.18 Copying karaf logs - PASS
Case 77: Bridging test between untagged and tagged hosts with different vlan id, with 2x2 leaf-spine topology and 3 ONOS instances - PASS
- 77.1 Apply cell to environment - PASS
- 77.2 Uninstalling Atomix - PASS
- 77.3 Uninstalling ONOS package - PASS
- 77.4 Installing Atomix - PASS
- 77.5 Installing ONOS package - PASS
- 77.6 Set up ONOS secure SSH - PASS
- 77.7 Checking ONOS service - PASS
- 77.8 Starting ONOS CLI sessions - PASS
- 77.9 Checking ONOS nodes - PASS
- 77.10 Checking ONOS applications - PASS
- 77.11 Starting Mininet Topology - PASS
- 77.12 Check whether the flow count is bigger than 74 - PASS
- 77.13 Check whether all flow status are ADDED - PASS
- 77.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 77.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 77.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE77 - PASS
- 77.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE77 - PASS
- 77.18 Stopping Mininet - PASS
- 77.19 Copying karaf logs - PASS
Case 78: Bridging test between untagged and tagged hosts with different vlan id, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances - PASS
- 78.1 Apply cell to environment - PASS
- 78.2 Uninstalling Atomix - PASS
- 78.3 Uninstalling ONOS package - PASS
- 78.4 Installing Atomix - PASS
- 78.5 Installing ONOS package - PASS
- 78.6 Set up ONOS secure SSH - PASS
- 78.7 Checking ONOS service - PASS
- 78.8 Starting ONOS CLI sessions - PASS
- 78.9 Checking ONOS nodes - PASS
- 78.10 Checking ONOS applications - PASS
- 78.11 Starting Mininet Topology - PASS
- 78.12 Check whether the flow count is bigger than 212 - PASS
- 78.13 Check whether all flow status are ADDED - PASS
- 78.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 78.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 78.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS
- 78.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS
- 78.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE78 - PASS
- 78.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE78 - PASS
- 78.20 Stopping Mininet - PASS
- 78.21 Copying karaf logs - PASS