<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric4/lastSuccessfulBuild/artifact/SRBridging_master_20-builds_graph.jpg", alt="SRBridging", style="width:525px;height:350px;border:0">

commit 312d98773222706dc480a4ad8aef31f0d09a9404 05f55ab3bd23ef0d67e243cb9b56ce884079a435 (HEAD -] master, origin/master, origin/HEAD)
Author: Ray Milkey [ray@opennetworking.orgjjosep004c [Jobin_Joseph@comcast.com]
AuthorDate: Mon Tue Aug 20 1621 09:0901:54 10 2018 -07000400
Commit: Ray Milkey Charles Chan [ray@opennetworkingcharles@opennetworking.org]
CommitDate: Mon Wed Aug 20 1622 00:0934:54 12 2018 -0700
Starting snapshot 1.15.0-SNAPSHOT+0000

DHCP servers MAC remain unresolved for connectPoints until org.onosproject.dhcprelay app toggle

Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR and 3 ONOS instances - PASS

...

  • 48.1 Apply cell to environment - PASS (tick)
  • 48.2 Uninstalling Atomix - PASS (tick)
  • 48.3 Uninstalling ONOS package - PASS (tick)
  • 48.4 Installing Atomix - PASS (tick)
  • 48.5 Installing ONOS package - PASS (tick)
  • 48.6 Set up ONOS secure SSH - PASS (tick)
  • 48.7 Checking ONOS service - PASS (tick)
  • 48.8 Starting ONOS CLI sessions - PASS (tick)
  • 48.9 Checking ONOS nodes - PASS (tick)
  • 48.10 Checking ONOS applications - PASS (tick)
  • 48.11 Starting Mininet Topology - PASS (tick)
  • 48.12 Check whether the flow count is bigger than 212 - PASS (tick)
  • 48.13 Check whether all flow status are ADDED - PASS (tick)
  • 48.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 48.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 48.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 48.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)
  • 48.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE48 - PASS (tick)
  • 48.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE48 - PASS (tick)
  • 48.20 Stopping Mininet - PASS (tick)
  • 48.21 Copying karaf logs - PASS (tick)

Case 55: Bridging test between two untagged hosts with different vlan id, with single ToR and 3 ONOS instances -

...

PASS

  • 55.1 Apply cell to environment - PASS (tick)
  • 55.2 Uninstalling Atomix - PASS (tick)
  • 55.3 Uninstalling ONOS package - PASS (tick)
  • 55.4 Installing Atomix - PASS (tick)
  • 55.5 Installing ONOS package - PASS (tick)
  • 55.6 Set up ONOS secure SSH - PASS (tick)
  • 55.7 Checking ONOS service - PASS (tick)
  • 55.8 Starting ONOS CLI sessions - PASS (tick)
  • 55.9 Checking ONOS nodes - PASS (tick)
  • 55.10 Checking ONOS applications - PASS (tick)
  • 55.11 Starting Mininet Topology - PASS (tick)
  • 55.12 Check whether the flow count is bigger than 28 - FAIL (error)
  • Flow count looks wrong: False
  • PASS (tick)
  • 55.13 Check whether all flow status are ADDED - PASS (tick)
  • 55.14 Check whether the flow count of device of:0000000000000001 is bigger than 28 - FAIL (error)
  • Flow count looks wrong.
  • PASS (tick)
  • 55.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE55 - PASS (tick)
  • 55.16 Stopping Mininet - PASS (tick)
  • 55.17 Copying karaf logs - PASS (tick)

...