Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Published from Jenkins build: https://jenkins.onosproject.org/job/SR-pipeline-1.14/1109/

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric3/lastSuccessfulBuild/artifact/SRClusterRestart_onos-1.14_20-builds_graph.jpg", alt="SRClusterRestart", style="width:525px;height:350px;border:0">

commit 0406d56598cae204e4cd946348d67ed81f18176f d8f04aadeac169949a3f403e7d051c8bef63d82c (HEAD -] onos-1.14, origin/onos-1.14)
Author: pier Carmelo Cascone [pier@opennetworkingcarmelo@opennetworking.org]
AuthorDate: Tue Nov 27 11:23:50 Thu Dec 13 23:16:10 2018 -0800
Commit: Pier Luigi Ventre [pier@opennetworkingCarmelo Cascone [carmelo@opennetworking.org]
CommitDate: Fri Dec 7 14 20:0901:26 49 2018 +0000
Provides a separate executor to handle map events.
--
(cherry picked from commit 8f35163338b78556fdc8680efa7125b53e75212e)

Working STC trellis-p4 scenario with connectivity test

Case 1: Cluster Restart test with 2x2 Leaf-spine - FAIL

...

  • 2.1 Apply cell to environment - PASS (tick)
  • 2.2 Uninstalling Atomix - PASS (tick)
  • 2.3 Uninstalling ONOS package - PASS (tick)
  • 2.4 Creating ONOS package - PASS (tick)
  • 2.5 Installing Atomix - PASS (tick)
  • 2.6 Installing ONOS package - PASS (tick)
  • 2.7 Set up ONOS secure SSH - PASS (tick)
  • 2.8 Checking ONOS service - PASS (tick)
  • 2.9 Starting ONOS CLI sessions - PASS (tick)
  • 2.10 Checking ONOS nodes - PASS (tick)
  • 2.11 Checking ONOS applications - PASS (tick)
  • 2.12 Starting Mininet Topology - PASS (tick)
  • 2.13 Check whether the flow count is bigger than 350 - PASS (tick)
  • 2.14 Check whether all flow status are ADDED - PASS (tick)
  • 2.15 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.16 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2 - PASS (tick)
  • 2.17 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2 - PASS (tick)
  • 2.18 Killing ONOS instances with index(es): [0, 1, 2] - PASS (tick)
  • 2.19 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2_Failure - FAIL (error)
    • IP connectivity failed
  • 2.20 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_Failure - PASS (tick)
  • 2.21 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_Failure - PASS (tick)
  • 2.22 Recovering ONOS instances with index(es): [0, 1, 2] - PASS (tick)
  • 2.23 Checking if ONOS CLI is ready - PASS (tick)
  • 2.24 Checking if ONOS CLI is ready - PASS (tick)
  • 2.25 Checking if ONOS CLI is ready - PASS (tick)
  • 2.26 Checking ONOS nodes - PASS (tick)
  • 2.27 Check number of topology elements - PASS (tick)
  • 2.28 Check whether the flow count is bigger than 350 - PASS (tick)
  • 2.29 Check whether all flow status are ADDED - PASS (tick)
  • 2.30 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2_Failure - FAIL (error)
    • IP connectivity failed
  • 2.31 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_Failure - PASS (tick)
  • 2.32 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_Failure - PASS (tick)
  • 2.33 Stopping Mininet - PASS (tick)
  • 2.34 Copying karaf logs - PASS (tick)

Case 3: Cluster Restart test with single switch -

...

FAIL

  • 3.1 Apply cell to environment - PASS (tick)
  • 3.2 Uninstalling Atomix - PASS (tick)
  • 3.3 Uninstalling ONOS package - PASS (tick)
  • 3.4 Creating ONOS package - PASS (tick)
  • 3.5 Installing Atomix - PASS (tick)
  • 3.6 Installing ONOS package - PASS (tick)
  • 3.7 Set up ONOS secure SSH - PASS (tick)FAIL (error)
    • Failed to secure ssh
  • 3.8 Checking ONOS service - PASS (tick)
  • 3.9 Starting ONOS CLI sessions - PASS (tick)
  • 3.10 Checking ONOS nodes - PASS (tick)
  • 3.11 Checking ONOS applications - PASS (tick)
  • 3.12 Starting Mininet Topology - PASS (tick)
  • 3.13 Check whether the flow count is bigger than 15 - PASS (tick)
  • 3.14 Check whether all flow status are ADDED - PASS (tick)
  • 3.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE3 - PASS (tick)
  • 3.16 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3 - PASS (tick)
  • 3.17 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3 - PASS (tick)
  • 3.18 Killing ONOS instances with index(es): [0, 1, 2] - PASS (tick)
  • 3.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE3_Failure - PASS (tick)
  • 3.20 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3_Failure - PASS (tick)
  • 3.21 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3_Failure - PASS (tick)
  • 3.22 Recovering ONOS instances with index(es): [0, 1, 2] - PASS (tick)
  • 3.23 Checking if ONOS CLI is ready - PASS (tick)
  • 3.24 Checking if ONOS CLI is ready - PASS (tick)
  • 3.25 Checking if ONOS CLI is ready - PASS (tick)
  • 3.26 Checking ONOS nodes - PASS (tick)
  • 3.27 Check number of topology elements - PASS (tick)
  • 3.28 Check whether the flow count is bigger than 15 - PASS (tick)
  • 3.29 Check whether all flow status are ADDED - PASS (tick)
  • 3.30 Verify full connectivity for [u'h1', u'h2'] with tag CASE3_Failure - PASS (tick)
  • 3.31 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3_Failure - PASS (tick)
  • 3.32 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3_Failure - PASS (tick)
  • 3.33 Stopping Mininet - PASS (tick)
  • 3.34 Copying karaf logs - PASS (tick)