Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Published from Jenkins build: https://jenkins.onosproject.org/job/SR-pipeline-master/197/

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric4/lastSuccessfulBuild/artifact/SRSwitchFailure_master_20-builds_graph.jpg", alt="SRSwitchFailure", style="width:525px;height:350px;border:0">

commit 92cc2685593d51fe26360913592279aa327182b5 4828f18c01d9c754da3b0c5da32e3d4be147111a (HEAD -] master, origin/master, origin/HEAD)
Author: Ray Milkey Andrea Campanella [ray@opennetworkingandrea@opennetworking.org]
AuthorDate: Fri Aug 17 1024 14:0718:57 37 2018 -0700+0200
Commit: Thomas Vachuska Andrea Campanella [tom@opennetworkingandrea@opennetworking.org]
CommitDate: Fri Aug 17 24 17:5103:20 24 2018 +0000
remove redundant definition for ONOS_VERSION
Fixing restconf Bazel build

Case 1: Switch Failure test with 2x2 Leaf-spine and 1 Onos - FAIL

...

  • 1.1 Constructing test variables - PASS (tick)
  • 1.2 Apply cell to environment - PASS (tick)
  • 1.3 Uninstalling Atomix - PASS (tick)
  • 1.4 Uninstalling ONOS package - PASS (tick)
  • 1.5 Creating ONOS package - PASS (tick)
  • 1.6 Installing Atomix - PASS (tick)
  • 1.7 Installing ONOS package - PASS (tick)
  • 1.8 Set up ONOS secure SSH - PASS (tick)
  • 1.9 Checking ONOS service - PASS (tick)
  • 1.10 Starting ONOS CLI sessions - PASS (tick)
  • 1.11 Checking ONOS nodes - PASS (tick)
  • 1.12 Checking ONOS applications - PASS (tick)
  • 1.13 Starting Mininet Topology - PASS (tick)
  • 1.14 Check whether the flow count is bigger than 116 - PASS (tick)
  • 1.15 Check whether all flow status are ADDED - PASS (tick)
  • 1.16 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.17 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1 - PASS (tick)
  • 1.18 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1 - PASS (tick)
  • 1.19 Kill ['spine101'] - FAIL (error)
  • Failed to kill switch?
  • PASS (tick)
  • 1.20 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.21 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_Failure - PASS (tick)
  • 1.22 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_Failure - PASS (tick)
  • 1.23 Recovering ['spine101'] - FAIL (error)
    • Failed to recover switch?
  • 1.24 Check whether the flow count is bigger than 116 - PASS (tick)
  • 1.25 Check whether all flow status are ADDED - PASS (tick)
  • 1.26 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_Recovery - FAIL (error)
    • IP connectivity failed
  • 1.27 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_Recovery - PASS (tick)
  • 1.28 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_Recovery - PASS (tick)
  • 1.29 Stopping Mininet - PASS (tick)
  • 1.30 Copying karaf logs - PASS (tick)

...