Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
HTML |
---|
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric2/lastSuccessfulBuild/artifact/SRBridging_onos-1.15_20-builds_graph.jpg", alt="SRBridging", style="width:525px;height:350px;border:0"> |
commit 7650097a0d140cc8195e71a6a2409ebe66a87fdb 7898ceda95b0e27a048c9fcee5e5c8daa332a4d4 (HEAD -] onos-1.15, origin/onos-1.15)
Author: Daniel Park Jian Li [danpyguni@gmail.mcpark84@gmail.com]
AuthorDate: Mon Nov 19 18:58:35 2018 Oct 5 22:36:41 2020 +0900
Commit: Jian Li [pyguni@gmail.com]
CommitDate: Tue Nov 20 19:06:57 2018 +0900
Fixes ARP-related flow rules in VLAN case.Mon Oct 5 22:56:34 2020 +0900
Fix: make all openstack resource name optional
Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR and 3 ONOS instances - PASS
...
- 17.1 Apply cell to environment - PASS
- 17.2 Uninstalling Atomix - PASS
- 17.3 Uninstalling ONOS package - PASS
- 17.4 Installing Atomix - PASS
- 17.5 Installing ONOS package - PASS
- 17.6 Set up ONOS secure SSH - PASS
- 17.7 Checking ONOS service - PASS
- 17.8 Starting ONOS CLI sessions - PASS
- 17.9 Checking ONOS nodes - PASS
- 17.10 Checking ONOS applications - PASS
- 17.11 Starting Mininet Topology - PASS
- 17.12 Check whether the flow count is bigger than 74 - PASS
- 17.13 Check whether all flow status are ADDED - PASS
- 17.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 17.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 17.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE17 - PASS
- 17.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE17 - PASS
- 17.18 Stopping Mininet - PASS
- 17.19 Copying karaf logs - PASS
Case 18: Bridging test between two tagged hosts, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances -
...
FAIL
- 18.1 Apply cell to environment - PASS
- 18.2 Uninstalling Atomix - PASS
- 18.3 Uninstalling ONOS package - PASS
- 18.4 Installing Atomix - PASS
- 18.5 Installing ONOS package - PASS
- 18.6 Set up ONOS secure SSH - PASS FAIL
- Failed to secure ssh
- 18.7 Checking ONOS service - PASS
- 18.8 Starting ONOS CLI sessions - PASS
- 18.9 Checking ONOS nodes - PASS
- 18.10 Checking ONOS applications - PASS
- 18.11 Starting Mininet Topology - PASS
- 18.12 Check whether the flow count is bigger than 212 - PASS
- 18.13 Check whether all flow status are ADDED - PASS
- 18.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 18.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 18.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS
- 18.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS
- 18.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE18 - PASS
- 18.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE18 - PASS
- 18.20 Stopping Mininet - PASS
- 18.21 Copying karaf logs - PASS
...
- 56.1 Apply cell to environment - PASS
- 56.2 Uninstalling Atomix - PASS
- 56.3 Uninstalling ONOS package - PASS
- 56.4 Installing Atomix - PASS
- 56.5 Installing ONOS package - PASS
- 56.6 Set up ONOS secure SSH - PASS
- 56.7 Checking ONOS service - PASS
- 56.8 Starting ONOS CLI sessions - PASS
- 56.9 Checking ONOS nodes - PASS
- 56.10 Checking ONOS applications - PASS
- 56.11 Starting Mininet Topology - PASS
- 56.12 Check whether the flow count is bigger than 74 - PASS
- 56.13 Check whether all flow status are ADDED - PASS
- 56.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 56.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 56.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE56 - PASS
- 56.17 Stopping Mininet - PASS
- 56.18 Copying karaf logs - PASS
Case 57: Bridging test between two untagged hosts with different vlan id, with 2x2 leaf-spine topology and 3 ONOS instances -
...
PASS
- 57.1 Apply cell to environment - PASS
- 57.2 Uninstalling Atomix - PASS
- 57.3 Uninstalling ONOS package - PASS
- 57.4 Installing Atomix - PASS
- 57.5 Installing ONOS package - PASS
- 57.6 Set up ONOS secure SSH - PASS
- 57.7 Checking ONOS service - PASS
- 57.8 Starting ONOS CLI sessions - PASS
- 57.9 Checking ONOS nodes - PASS
- 57.10 Checking ONOS applications - PASS
- 57.11 Starting Mininet Topology - PASS
- 57.12 Check whether the flow count is bigger than 74 - PASS
- 57.13 Check whether all flow status are ADDED - PASS
- 57.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 57.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - FAIL Flow count looks wrong.
- PASS
- 57.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE57 - PASS
- 57.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE57 - PASS
- 57.18 Stopping Mininet - PASS
- 57.19 Copying karaf logs - PASS
...