Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Published from Jenkins build: https://jenkins.onosproject.org/job/SR-pipeline-1.15/1253/

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric2/lastSuccessfulBuild/artifact/SRBridging_onos-1.15_20-builds_graph.jpg", alt="SRBridging", style="width:525px;height:350px;border:0">

commit 2b6073de47a41549a9120460515f9bd9398885a4 828ab3276da650dd7e51d14e86179db81353f6c9 (HEAD -] onos-1.15, origin/onos-1.15)
Author: Charles Chan Jian Li [rascov@gmailpyguni@gmail.com]
AuthorDate: Wed Apr 10 17:12:20 2019 -0700Fri Aug 16 21:39:27 2019 +0900
Commit: Thomas Vachuska Jian Li [tom@opennetworkingpyguni@gmail.orgcom]
CommitDate: Fri Apr 12 20:52:42 Aug 16 21:59:21 2019 +0000
Allowed apps to specify whether the existing component config value should be overridden0900

Refactor: remove some code duplication on k8s sync state

Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR and 3 ONOS instances - PASS

...

  • 5.1 Constructing test variables - PASS (tick)
  • 5.2 Apply cell to environment - PASS (tick)
  • 5.3 Uninstalling Atomix - PASS (tick)
  • 5.4 Uninstalling ONOS package - PASS (tick)
  • 5.5 Creating ONOS package - PASS (tick)
  • 5.6 Installing Atomix - PASS (tick)
  • 5.7 Installing ONOS package - PASS (tick)
  • 5.8 Set up ONOS secure SSH - PASS (tick)
  • 5.9 Checking ONOS service - PASS (tick)
  • 5.10 Starting ONOS CLI sessions - PASS (tick)
  • 5.11 Checking ONOS nodes - PASS (tick)
  • 5.12 Checking ONOS applications - PASS (tick)
  • 5.13 Starting Mininet Topology - PASS (tick)
  • 5.14 Check whether the flow count is bigger than 28 - PASS (tick)
  • 5.15 Check whether all flow status are ADDED - PASS (tick)
  • 5.16 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS (tick)
  • 5.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE5 - PASS (tick)
  • 5.18 Stopping Mininet - PASS (tick)
  • 5.19 Copying karaf logs - PASS (tick)

Case 6: Bridging test between two untagged hosts on vlan-untagged port, with dual-homed ToR and 3 ONOS instances -

...

PASS

  • 6.1 Apply cell to environment - PASS (tick)
  • 6.2 Uninstalling Atomix - PASS (tick)
  • 6.3 Uninstalling ONOS package - PASS (tick)
  • 6.4 Installing Atomix - PASS (tick)
  • 6.5 Installing ONOS package - PASS (tick)
  • 6.6 Set up ONOS secure SSH - PASS (tick)
  • 6.7 Checking ONOS service - PASS (tick)
  • 6.8 Starting ONOS CLI sessions - PASS (tick)
  • 6.9 Checking ONOS nodes - PASS (tick)
  • 6.10 Checking ONOS applications - PASS (tick)
  • 6.11 Starting Mininet Topology - PASS (tick)
  • 6.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 6.13 Check whether all flow status are ADDED - PASS (tick)
  • 6.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 6.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 6.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE6 - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 6.17 Stopping Mininet - PASS (tick)
  • 6.18 Copying karaf logs - PASS (tick)

...

  • 17.1 Apply cell to environment - PASS (tick)
  • 17.2 Uninstalling Atomix - PASS (tick)
  • 17.3 Uninstalling ONOS package - PASS (tick)
  • 17.4 Installing Atomix - PASS (tick)
  • 17.5 Installing ONOS package - PASS (tick)
  • 17.6 Set up ONOS secure SSH - PASS (tick)
  • 17.7 Checking ONOS service - PASS (tick)
  • 17.8 Starting ONOS CLI sessions - PASS (tick)
  • 17.9 Checking ONOS nodes - PASS (tick)
  • 17.10 Checking ONOS applications - PASS (tick)
  • 17.11 Starting Mininet Topology - PASS (tick)
  • 17.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 17.13 Check whether all flow status are ADDED - PASS (tick)
  • 17.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 17.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 17.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE17 - PASS (tick)
  • 17.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE17 - PASS (tick)
  • 17.18 Stopping Mininet - PASS (tick)
  • 17.19 Copying karaf logs - PASS (tick)

Case 18: Bridging test between two tagged hosts, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances -

...

PASS

  • 18.1 Apply cell to environment - PASS (tick)
  • 18.2 Uninstalling Atomix - PASS (tick)
  • 18.3 Uninstalling ONOS package - PASS (tick)
  • 18.4 Installing Atomix - PASS (tick)
  • 18.5 Installing ONOS package - PASS (tick)
  • 18.6 Set up ONOS secure SSH - PASS (tick)
  • 18.7 Checking ONOS service - PASS (tick)
  • 18.8 Starting ONOS CLI sessions - PASS (tick)
  • 18.9 Checking ONOS nodes - PASS (tick)
  • 18.10 Checking ONOS applications - PASS (tick)
  • 18.11 Starting Mininet Topology - PASS (tick)
  • 18.12 Check whether the flow count is bigger than 212 - PASS (tick)
  • 18.13 Check whether all flow status are ADDED - PASS (tick)
  • 18.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 18.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - FAIL (error)
    • Flow count looks wrong: 18
  • PASS (tick)
  • 18 18.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 18.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - FAIL (error)
    • Flow count looks wrong: 18
  • PASS (tick)
  • 18 18.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE18 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 18.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE18 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 18.20 Stopping Mininet - PASS (tick)
  • 18.21 Copying karaf logs - PASS (tick)

...

  • 27.1 Apply cell to environment - PASS (tick)
  • 27.2 Uninstalling Atomix - PASS (tick)
  • 27.3 Uninstalling ONOS package - PASS (tick)
  • 27.4 Installing Atomix - PASS (tick)
  • 27.5 Installing ONOS package - PASS (tick)
  • 27.6 Set up ONOS secure SSH - PASS (tick)
  • 27.7 Checking ONOS service - PASS (tick)
  • 27.8 Starting ONOS CLI sessions - PASS (tick)
  • 27.9 Checking ONOS nodes - PASS (tick)
  • 27.10 Checking ONOS applications - PASS (tick)
  • 27.11 Starting Mininet Topology - PASS (tick)
  • 27.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 27.13 Check whether all flow status are ADDED - PASS (tick)
  • 27.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 27.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 27.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE27 - PASS (tick)
  • 27.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE27 - PASS (tick)
  • 27.18 Stopping Mininet - PASS (tick)
  • 27.19 Copying karaf logs - PASS (tick)

Case 28: Bridging test between two untagged hosts on vlan-native port, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances -

...

PASS

  • 28.1 Apply cell to environment - PASS (tick)
  • 28.2 Uninstalling Atomix - PASS (tick)
  • 28.3 Uninstalling ONOS package - PASS (tick)
  • 28.4 Installing Atomix - PASS (tick)
  • 28.5 Installing ONOS package - PASS (tick)
  • 28.6 Set up ONOS secure SSH - PASS (tick)
  • 28.7 Checking ONOS service - PASS (tick)
  • 28.8 Starting ONOS CLI sessions - PASS (tick)
  • 28.9 Checking ONOS nodes - PASS (tick)
  • 28.10 Checking ONOS applications - PASS (tick)
  • 28.11 Starting Mininet Topology - PASS (tick)
  • 28.12 Check whether the flow count is bigger than 212 - PASS (tick)
  • 28.13 Check whether all flow status are ADDED - PASS (tick)
  • 28.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 28.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 28.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 28.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - FAIL (error)
  • Flow count looks wrong: 18
  • PASS (tick)
  • 28.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE28 - PASS (tick)
  • 28.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE28 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 28.20 Stopping Mininet - PASS (tick)
  • 28.21 Copying karaf logs - PASS (tick)

...

  • 75.1 Apply cell to environment - PASS (tick)
  • 75.2 Uninstalling Atomix - PASS (tick)
  • 75.3 Uninstalling ONOS package - PASS (tick)
  • 75.4 Installing Atomix - PASS (tick)
  • 75.5 Installing ONOS package - PASS (tick)
  • 75.6 Set up ONOS secure SSH - PASS (tick)
  • 75.7 Checking ONOS service - PASS (tick)
  • 75.8 Starting ONOS CLI sessions - PASS (tick)
  • 75.9 Checking ONOS nodes - PASS (tick)
  • 75.10 Checking ONOS applications - PASS (tick)
  • 75.11 Starting Mininet Topology - PASS (tick)
  • 75.12 Check whether the flow count is bigger than 28 - PASS (tick)
  • 75.13 Check whether all flow status are ADDED - PASS (tick)
  • 75.14 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS (tick)
  • 75.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE75 - PASS (tick)
  • 75.16 Stopping Mininet - PASS (tick)
  • 75.17 Copying karaf logs - PASS (tick)

Case 76: Bridging test between untagged and tagged hosts with different vlan id, with dual-homed ToR and 3 ONOS instances -

...

  • 76.1 Apply cell to environment - PASS (tick)
  • 76.2 Uninstalling Atomix - PASS (tick)
  • 76.3 Uninstalling ONOS package - PASS (tick)
  • 76.4 Installing Atomix - PASS (tick)
  • 76.5 Installing ONOS package - PASS (tick)
  • 76.6 Set up ONOS secure SSH - PASS (tick)
  • 76.7 Checking ONOS service - PASS (tick)
  • 76.8 Starting ONOS CLI sessions - PASS (tick)
  • 76.9 Checking ONOS nodes - PASS (tick)
  • 76.10 Checking ONOS applications - PASS (tick)
  • 76.11 Starting Mininet Topology - PASS (tick)
  • 76.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 76.13 Check whether all flow status are ADDED - PASS (tick)
  • 76.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 76.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 76.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE76 - PASS (tick)
  • 76.17 Stopping Mininet - PASS (tick)
  • 76.18 Copying karaf logs - PASS (tick)

Case 77: Bridging test between untagged and tagged hosts with different vlan id, with 2x2 leaf-spine topology and 3 ONOS instances - PASS

  • 77.1 Apply cell to environment - PASS (tick)
  • 77.2 Uninstalling Atomix - PASS (tick)
  • 77.3 Uninstalling ONOS package - PASS (tick)
  • 77.4 Installing Atomix - PASS (tick)
  • 77.5 Installing ONOS package - PASS (tick)
  • 77.6 Set up ONOS secure SSH - PASS (tick)
  • 77.7 Checking ONOS service - PASS (tick)
  • 77.8 Starting ONOS CLI sessions - PASS (tick)
  • 77.9 Checking ONOS nodes - PASS (tick)
  • 77.10 Checking ONOS applications - PASS (tick)
  • 77.11 Starting Mininet Topology - PASS (tick)
  • 77.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 77.13 Check whether all flow status are ADDED - PASS (tick)
  • 77.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 77.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 77.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE77 - PASS (tick)
  • 77.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE77 - PASS (tick)
  • 77.18 Stopping Mininet - PASS (tick)
  • 77.19 Copying karaf logs - PASS (tick)

Case 78: Bridging test between untagged and tagged hosts with different vlan id, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances - PASS

...

FAIL