commit a4298db46eec35fec1eef9c0d81800f325933c4a 7898ceda95b0e27a048c9fcee5e5c8daa332a4d4 (HEAD -] onos-1.15, origin/onos-1.15)
Author: Harshada Chaundkar [Harshada_Chaundkar@comcastJian Li [pyguni@gmail.com]
AuthorDate: Mon Feb 18 12:27:34 2019 -0500Oct 5 22:36:41 2020 +0900
Commit: Charles Chan Jian Li [rascov@gmailpyguni@gmail.com]
CommitDate: Wed Feb 20 15:18:44 2019 -0800
Potential Null Pointer Exception fix for Cpman, Groups , Flows and Mastership APIMon Oct 5 22:56:34 2020 +0900
Fix: make all openstack resource name optional
Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR and 3 ONOS instances - PASS
...
- 7.1 Apply cell to environment - PASS
- 7.2 Uninstalling Atomix - PASS
- 7.3 Uninstalling ONOS package - PASS
- 7.4 Installing Atomix - PASS
- 7.5 Installing ONOS package - PASS
- 7.6 Set up ONOS secure SSH - PASS
- 7.7 Checking ONOS service - PASS
- 7.8 Starting ONOS CLI sessions - PASS
- 7.9 Checking ONOS nodes - PASS
- 7.10 Checking ONOS applications - PASS
- 7.11 Starting Mininet Topology - PASS
- 7.12 Check whether the flow count is bigger than 74 - PASS
- 7.13 Check whether all flow status are ADDED - PASS
- 7.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 7.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 7.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE7 - PASS
- 7.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE7 - PASS
- 7.18 Stopping Mininet - PASS
- 7.19 Copying karaf logs - PASS
Case 8: Bridging test between two untagged hosts on vlan-untagged port, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances -
...
PASS
- 8.1 Apply cell to environment - PASS
- 8.2 Uninstalling Atomix - PASS
- 8.3 Uninstalling ONOS package - PASS
- 8.4 Installing Atomix - PASS
- 8.5 Installing ONOS package - PASS
- 8.6 Set up ONOS secure SSH - PASS
- 8.7 Checking ONOS service - PASS
- 8.8 Starting ONOS CLI sessions - PASS
- 8.9 Checking ONOS nodes - PASS
- 8.10 Checking ONOS applications - PASS
- 8.11 Starting Mininet Topology - PASS
- 8.12 Check whether the flow count is bigger than 212 - FAIL
- Flow count looks wrong: 102
- PASS
- 8.13 Check whether all flow status are ADDED - PASS
- 8.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - FAIL
- Flow count looks wrong: 17
- PASS
- 8.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - FAIL
- Flow count looks wrong: 17
- PASS
- 8.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - FAIL
- PASS
- 8.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - FAIL
- Flow count looks wrong: 17
- PASS
- 8.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE8 - FAIL
- PASS
- 8.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE8 - FAIL
- IP connectivity failed
- PASS
- 8.20 Stopping Mininet - PASS
- 8.21 Copying karaf logs - PASS
...
- 17.1 Apply cell to environment - PASS
- 17.2 Uninstalling Atomix - PASS
- 17.3 Uninstalling ONOS package - PASS
- 17.4 Installing Atomix - PASS
- 17.5 Installing ONOS package - PASS
- 17.6 Set up ONOS secure SSH - PASS
- 17.7 Checking ONOS service - PASS
- 17.8 Starting ONOS CLI sessions - PASS
- 17.9 Checking ONOS nodes - PASS
- 17.10 Checking ONOS applications - PASS
- 17.11 Starting Mininet Topology - PASS
- 17.12 Check whether the flow count is bigger than 74 - PASS
- 17.13 Check whether all flow status are ADDED - PASS
- 17.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 17.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 17.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE17 - PASS
- 17.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE17 - PASS
- 17.18 Stopping Mininet - PASS
- 17.19 Copying karaf logs - PASS
Case 18: Bridging test between two tagged hosts, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances -
...
FAIL
- 18.1 Apply cell to environment - PASS
- 18.2 Uninstalling Atomix - PASS
- 18.3 Uninstalling ONOS package - PASS
- 18.4 Installing Atomix - PASS
- 18.5 Installing ONOS package - PASS
- 18.6 Set up ONOS secure SSH - PASS
FAIL
- Failed to secure ssh
- 18.7 Checking ONOS service - PASS
- 18.8 Starting ONOS CLI sessions - PASS
- 18.9 Checking ONOS nodes - PASS
- 18.10 Checking ONOS applications - PASS
- 18.11 Starting Mininet Topology - PASS
- 18.12 Check whether the flow count is bigger than 212 - PASS
- 18.13 Check whether all flow status are ADDED - PASS
- 18.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 18.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 18.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS
- 18.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS
- 18.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE18 - PASS
- 18.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE18 - PASS
- 18.20 Stopping Mininet - PASS
- 18.21 Copying karaf logs - PASS
...
- 76.1 Apply cell to environment - PASS
- 76.2 Uninstalling Atomix - PASS
- 76.3 Uninstalling ONOS package - PASS
- 76.4 Installing Atomix - PASS
- 76.5 Installing ONOS package - PASS
- 76.6 Set up ONOS secure SSH - PASS
- 76.7 Checking ONOS service - PASS
- 76.8 Starting ONOS CLI sessions - PASS
- 76.9 Checking ONOS nodes - PASS
- 76.10 Checking ONOS applications - PASS
- 76.11 Starting Mininet Topology - PASS
- 76.12 Check whether the flow count is bigger than 74 - PASS
- 76.13 Check whether all flow status are ADDED - PASS
- 76.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 76.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 76.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE76 - PASS
- 76.17 Stopping Mininet - PASS
- 76.18 Copying karaf logs - PASS
Case 77: Bridging test between untagged and tagged hosts with different vlan id, with 2x2 leaf-spine topology and 3 ONOS instances -
...
PASS
- 77.1 Apply cell to environment - PASS
- 77.2 Uninstalling Atomix - PASS
- 77.3 Uninstalling ONOS package - PASS
- 77.4 Installing Atomix - PASS
- 77.5 Installing ONOS package - PASS
- 77.6 Set up ONOS secure SSH - PASS
- 77.7 Checking ONOS service - PASS
- 77.8 Starting ONOS CLI sessions - PASS
- 77.9 Checking ONOS nodes - PASS
- 77.10 Checking ONOS applications - PASS
- 77.11 Starting Mininet Topology - PASS
- 77.12 Check whether the flow count is bigger than 74 - PASS
- 77.13 Check whether all flow status are ADDED - PASS
- 77.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 77.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - FAIL
- PASS
- 77.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE77 - PASS
- 77.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE77 - PASS
- 77.18 Stopping Mininet - PASS
- 77.19 Copying karaf logs - PASS
...