Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
HTML |
---|
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric2/lastSuccessfulBuild/artifact/SRDynamicConf_onos-1.15_20-builds_graph.jpg", alt="SRDynamicConf", style="width:525px;height:350px;border:0"> |
commit 4b94dc0dfe74416dd946e86c5d3fac7c29097587 7898ceda95b0e27a048c9fcee5e5c8daa332a4d4 (HEAD -] onos-1.15, origin/onos-1.15)
Author: pier Jian Li [pier@opennetworkingpyguni@gmail.orgcom]
AuthorDate: Tue Nov 26 11:48:48 2019 +0100Mon Oct 5 22:36:41 2020 +0900
Commit: pier Jian Li [pier@opennetworkingpyguni@gmail.orgcom]
CommitDate: Mon Dec 2 10:43:50 2019 +0100
Adds coordination during host movementsOct 5 22:56:34 2020 +0900
Fix: make all openstack resource name optional
Case 13: Changing port configuration from untagged 10 to tagged 10, with 2x2 leaf-spine topology and 3 ONOS instances - PASS
...
- 23.1 Apply cell to environment - PASS
- 23.2 Uninstalling Atomix - PASS
- 23.3 Uninstalling ONOS package - PASS
- 23.4 Installing Atomix - PASS
- 23.5 Installing ONOS package - PASS
- 23.6 Set up ONOS secure SSH - PASS
- 23.7 Checking ONOS service - PASS
- 23.8 Starting ONOS CLI sessions - PASS
- 23.9 Checking ONOS nodes - PASS
- 23.10 Checking ONOS applications - PASS
- 23.11 Starting Mininet Topology - PASS
- 23.12 Check whether the flow count is bigger than 106 - PASS
- 23.13 Check whether all flow status are ADDED - PASS
- 23.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE23_Before - PASS
- 23.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_Before - PASS
- 23.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 23.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 23.18 Check whether the flow count is bigger than 106 - PASS
- 23.19 Check whether all flow status are ADDED - FAIL
- Flow status is wrong!
- 23.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_After - PASS
- 23.21 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE23_After - PASS
- 23.22 Stopping Mininet - PASS
- 23.23 Copying karaf logs - PASS
Case 33: Changing port configuration from untagged 10 to untagged 110, with 2x2 leaf-spine topology and 3 ONOS instances -
...
PASS
- 33.1 Apply cell to environment - PASS
- 33.2 Uninstalling Atomix - PASS
- 33.3 Uninstalling ONOS package - PASS
- 33.4 Installing Atomix - PASS
- 33.5 Installing ONOS package - PASS
- 33.6 Set up ONOS secure SSH - PASS
- 33.7 Checking ONOS service - PASS
- 33.8 Starting ONOS CLI sessions - PASS
- 33.9 Checking ONOS nodes - PASS
- 33.10 Checking ONOS applications - PASS
- 33.11 Starting Mininet Topology - PASS
- 33.12 Check whether the flow count is bigger than 104 - PASS
- 33.13 Check whether all flow status are ADDED - PASS
- 33.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE33_Before - PASS
- 33.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE33_Before - PASS
- 33.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 33.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 33.18 Check whether the flow count is bigger than 104 - PASS
- 33.19 Check whether all flow status are ADDED - FAIL Flow status is wrong!
- PASS
- 33.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE33_After - PASS
- 33.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE33_After - PASS
- 33.22 Stopping Mininet - PASS
- 33.23 Copying karaf logs - PASS
...
- 53.1 Apply cell to environment - PASS
- 53.2 Uninstalling Atomix - PASS
- 53.3 Uninstalling ONOS package - PASS
- 53.4 Installing Atomix - PASS
- 53.5 Installing ONOS package - PASS
- 53.6 Set up ONOS secure SSH - PASS
- 53.7 Checking ONOS service - PASS
- 53.8 Starting ONOS CLI sessions - PASS
- 53.9 Checking ONOS nodes - PASS
- 53.10 Checking ONOS applications - PASS
- 53.11 Starting Mininet Topology - PASS
- 53.12 Check whether the flow count is bigger than 104 - PASS
- 53.13 Check whether all flow status are ADDED - PASS
- 53.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE53_Before - PASS
- 53.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE53_Before - PASS
- 53.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 53.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 53.18 Check whether the flow count is bigger than 104 - PASS
- 53.19 Check whether all flow status are ADDED - PASS
- 53.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE53_After - PASS
- 53.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE53_After - PASS
- 53.22 Stopping Mininet - PASS
- 53.23 Copying karaf logs - PASS
Case 63: Changing port configuration from untagged 10 to tagged 120 with native 110, with 2x2 leaf-spine topology and 3 ONOS instances -
...
FAIL
- 63.1 Apply cell to environment - PASS
- 63.2 Uninstalling Atomix - PASS
- 63.3 Uninstalling ONOS package - PASS
- 63.4 Installing Atomix - PASS
- 63.5 Installing ONOS package - PASS
- 63.6 Set up ONOS secure SSH - PASS
- 63.7 Checking ONOS service - PASS
- 63.8 Starting ONOS CLI sessions - PASS
- 63.9 Checking ONOS nodes - PASS
- 63.10 Checking ONOS applications - PASS
- 63.11 Starting Mininet Topology - PASS
- 63.12 Check whether the flow count is bigger than 104 - PASS
- 63.13 Check whether all flow status are ADDED - PASS
- 63.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE63_Before - PASS
- 63.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE63_Before - PASS
- 63.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 63.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 63.18 Check whether the flow count is bigger than 104 - PASS
- 63.19 Check whether all flow status are ADDED - PASS FAIL
- Flow status is wrong!
- 63.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE63_After - PASS
- 63.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE63_After - PASS
- 63.22 Stopping Mininet - PASS
- 63.23 Copying karaf logs - PASS
...
- 103.1 Apply cell to environment - PASS
- 103.2 Uninstalling Atomix - PASS
- 103.3 Uninstalling ONOS package - PASS
- 103.4 Installing Atomix - PASS
- 103.5 Installing ONOS package - PASS
- 103.6 Set up ONOS secure SSH - PASS
- 103.7 Checking ONOS service - PASS
- 103.8 Starting ONOS CLI sessions - PASS
- 103.9 Checking ONOS nodes - PASS
- 103.10 Checking ONOS applications - PASS
- 103.11 Starting Mininet Topology - PASS
- 103.12 Check whether the flow count is bigger than 104 - PASS
- 103.13 Check whether all flow status are ADDED - PASS
- 103.14 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE103_Before - PASS
- 103.15 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 103.16 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 103.17 Check whether the flow count is bigger than 104 - PASS
- 103.18 Check whether all flow status are ADDED - PASS
- 103.19 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE103_After - PASS
- 103.20 Stopping Mininet - PASS
- 103.21 Copying karaf logs - PASS
Case 113: Changing port configuration from tagged 20 and native 10 to tagged 20, with 2x2 leaf-spine topology and 3 ONOS instances -
...
PASS
- 113.1 Apply cell to environment - PASS
- 113.2 Uninstalling Atomix - PASS
- 113.3 Uninstalling ONOS package - PASS
- 113.4 Installing Atomix - PASS
- 113.5 Installing ONOS package - PASS
- 113.6 Set up ONOS secure SSH - PASS
- 113.7 Checking ONOS service - PASS
- 113.8 Starting ONOS CLI sessions - PASS
- 113.9 Checking ONOS nodes - PASS
- 113.10 Checking ONOS applications - PASS
- 113.11 Starting Mininet Topology - PASS
- 113.12 Check whether the flow count is bigger than 104 - PASS
- 113.13 Check whether all flow status are ADDED - PASS
- 113.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE113_Before - PASS
- 113.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE113_Before - PASS
- 113.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 113.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 113.18 Check whether the flow count is bigger than 104 - PASS
- 113.19 Check whether all flow status are ADDED - FAIL
- Flow status is wrong!
- PASS
- 113.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE113_After - PASS
- 113.21 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE113_After - PASS
- 113.22 Stopping Mininet - PASS
- 113.23 Copying karaf logs - PASS
...
- 153.1 Apply cell to environment - PASS
- 153.2 Uninstalling Atomix - PASS
- 153.3 Uninstalling ONOS package - PASS
- 153.4 Installing Atomix - PASS
- 153.5 Installing ONOS package - PASS
- 153.6 Set up ONOS secure SSH - PASS
- 153.7 Checking ONOS service - PASS
- 153.8 Starting ONOS CLI sessions - PASS
- 153.9 Checking ONOS nodes - PASS
- 153.10 Checking ONOS applications - PASS
- 153.11 Starting Mininet Topology - PASS
- 153.12 Check whether the flow count is bigger than 106 - PASS
- 153.13 Check whether all flow status are ADDED - PASS
- 153.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE153_Before - PASS
- 153.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE153_Before - PASS
- 153.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 153.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 153.18 Check whether the flow count is bigger than 106 - PASS
- 153.19 Check whether all flow status are ADDED - PASS
- 153.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE153_After - PASS
- 153.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE153_After - PASS
- 153.22 Stopping Mininet - PASS
- 153.23 Copying karaf logs - PASS
Case 163: Changing port configuration from untagged 10 to tagged 20 and native 10, with 2x2 leaf-spine topology and 3 ONOS instances -
...
PASS
- 163.1 Apply cell to environment - PASS
- 163.2 Uninstalling Atomix - PASS
- 163.3 Uninstalling ONOS package - PASS
- 163.4 Installing Atomix - PASS
- 163.5 Installing ONOS package - PASS
- 163.6 Set up ONOS secure SSH - PASS
- 163.7 Checking ONOS service - PASS
- 163.8 Starting ONOS CLI sessions - PASS
- 163.9 Checking ONOS nodes - PASS
- 163.10 Checking ONOS applications - PASS
- 163.11 Starting Mininet Topology - PASS
- 163.12 Check whether the flow count is bigger than 106 - FAIL Flow count looks wrong: 91
- PASS
- 163.13 Check whether all flow status are ADDED - PASS
- 163.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE163_Before - FAIL
- IP connectivity failed
- PASS
- 163.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE163_Before - PASS
- 163.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - FAIL
- Flow count looks wrong: 17
- PASS
- 163.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - FAIL
- Flow count looks wrong: 40
- PASS
- 163.18 Check whether the flow count is bigger than 106 - FAIL
- Flow count looks wrong: 96
- PASS
- 163.19 Check whether all flow status are ADDED - PASS
- 163.20 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE163_After - FAIL
- IP connectivity failed
- PASS
- 163.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE163_After - PASS
- 163.22 Stopping Mininet - PASS
- 163.23 Copying karaf logs - PASS
...
- 203.1 Apply cell to environment - PASS
- 203.2 Uninstalling Atomix - PASS
- 203.3 Uninstalling ONOS package - PASS
- 203.4 Installing Atomix - PASS
- 203.5 Installing ONOS package - PASS
- 203.6 Set up ONOS secure SSH - PASS
- 203.7 Checking ONOS service - PASS
- 203.8 Starting ONOS CLI sessions - PASS
- 203.9 Checking ONOS nodes - PASS
- 203.10 Checking ONOS applications - PASS
- 203.11 Starting Mininet Topology - PASS
- 203.12 Check whether the flow count is bigger than 106 - PASS
- 203.13 Check whether all flow status are ADDED - PASS
- 203.14 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE203_Before - PASS
- 203.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE203_Before - PASS
- 203.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 203.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 203.18 Check whether the flow count is bigger than 106 - PASS
- 203.19 Check whether all flow status are ADDED - PASS
- 203.20 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE203_After - PASS
- 203.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE203_After - PASS
- 203.22 Stopping Mininet - PASS
- 203.23 Copying karaf logs - PASS
Case 213: Changing port configuration from tagged 20 and native 10 to tagged 20 and native 110, with 2x2 leaf-spine topology and 3 ONOS instances -
...
PASS
- 213.1 Apply cell to environment - PASS
- 213.2 Uninstalling Atomix - PASS
- 213.3 Uninstalling ONOS package - PASS
- 213.4 Installing Atomix - PASS
- 213.5 Installing ONOS package - PASS
- 213.6 Set up ONOS secure SSH - PASS
- 213.7 Checking ONOS service - PASS
- 213.8 Starting ONOS CLI sessions - PASS
- 213.9 Checking ONOS nodes - PASS
- 213.10 Checking ONOS applications - PASS
- 213.11 Starting Mininet Topology - PASS
- 213.12 Check whether the flow count is bigger than 106 - PASS
- 213.13 Check whether all flow status are ADDED - PASS
- 213.14 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE213_Before - PASS
- 213.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE213_Before - PASS
- 213.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 213.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - FAIL Flow count looks wrong: 19
- PASS
- 213.18 Check whether the flow count is bigger than 106 - PASS
- 213.19 Check whether all flow status are ADDED - PASS
- 213.20 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE213_After - PASS
- 213.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE213_After - PASS
- 213.22 Stopping Mininet - PASS
- 213.23 Copying karaf logs - PASS
...