  • 33.1 Apply cell to environment - PASS (tick)
  • 33.2 Uninstalling Atomix - PASS (tick)
  • 33.3 Uninstalling ONOS package - PASS (tick)
  • 33.4 Installing Atomix - PASS (tick)
  • 33.5 Installing ONOS package - PASS (tick)
  • 33.6 Set up ONOS secure SSH - PASS (tick)
  • 33.7 Checking ONOS service - PASS (tick)
  • 33.8 Starting ONOS CLI sessions - PASS (tick)
  • 33.9 Checking ONOS nodes - PASS (tick)
  • 33.10 Checking ONOS applications - PASS (tick)
  • 33.11 Starting Mininet Topology - PASS (tick)
  • 33.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 33.13 Check whether all flow status are ADDED - PASS (tick)
  • 33.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE33_Before - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 33.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE33_Before - PASS (tick)
  • 33.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 33.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 33.18 Check whether the flow count is bigger than 104 - PASS (tick)
  • 33.19 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 33.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE33_After - PASS (tick)
  • 33.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE33_After - PASS (tick)
  • 33.22 Stopping Mininet - PASS (tick)
  • 33.23 Copying karaf logs - PASS (tick)

...

  • 103.1 Apply cell to environment - PASS (tick)
  • 103.2 Uninstalling Atomix - PASS (tick)
  • 103.3 Uninstalling ONOS package - PASS (tick)
  • 103.4 Installing Atomix - PASS (tick)
  • 103.5 Installing ONOS package - PASS (tick)
  • 103.6 Set up ONOS secure SSH - PASS (tick)
  • 103.7 Checking ONOS service - PASS (tick)
  • 103.8 Starting ONOS CLI sessions - PASS (tick)
  • 103.9 Checking ONOS nodes - PASS (tick)
  • 103.10 Checking ONOS applications - PASS (tick)
  • 103.11 Starting Mininet Topology - PASS (tick)
  • 103.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 103.13 Check whether all flow status are ADDED - PASS (tick)
  • 103.14 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE103_Before - PASS (tick)
  • 103.15 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 103.16 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 103.17 Check whether the flow count is bigger than 104 - PASS (tick)
  • 103.18 Check whether all flow status are ADDED - PASS (tick)
  • 103.19 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE103_After - PASS (tick)
  • 103.20 Stopping Mininet - PASS (tick)
  • 103.21 Copying karaf logs - PASS (tick)

Case 113: Changing port configuration from tagged 20 and native 10 to tagged 20, with 2x2 leaf-spine topology and 3 ONOS instances -

...

PASS

  • 113.1 Apply cell to environment - PASS (tick)
  • 113.2 Uninstalling Atomix - PASS (tick)
  • 113.3 Uninstalling ONOS package - PASS (tick)
  • 113.4 Installing Atomix - PASS (tick)
  • 113.5 Installing ONOS package - PASS (tick)
  • 113.6 Set up ONOS secure SSH - PASS (tick)
  • 113.7 Checking ONOS service - PASS (tick)
  • 113.8 Starting ONOS CLI sessions - PASS (tick)
  • 113.9 Checking ONOS nodes - PASS (tick)
  • 113.10 Checking ONOS applications - PASS (tick)
  • 113.11 Starting Mininet Topology - PASS (tick)
  • 113.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 113.13 Check whether all flow status are ADDED - PASS (tick)
  • 113.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE113_Before - PASS (tick)
  • 113.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE113_Before - PASS (tick)
  • 113.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 113.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 113.18 Check whether the flow count is bigger than 104 - PASS (tick)
  • 113.19 Check whether all flow status are ADDED - FAIL (error)
  • Flow status is wrong!
  • PASS (tick)
  • 113.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE113_After - PASS (tick)
  • 113.21 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE113_After - PASS (tick)
  • 113.22 Stopping Mininet - PASS (tick)
  • 113.23 Copying karaf logs - PASS (tick)

Case 123: Changing port configuration from tagged 20 and native 10 to tagged 20 and native 110, with 2x2 leaf-spine topology and 3 ONOS instances -

...

PASS

  • 123.1 Apply cell to environment - PASS (tick)
  • 123.2 Uninstalling Atomix - PASS (tick)
  • 123.3 Uninstalling ONOS package - PASS (tick)
  • 123.4 Installing Atomix - PASS (tick)
  • 123.5 Installing ONOS package - PASS (tick)
  • 123.6 Set up ONOS secure SSH - PASS (tick)
  • 123.7 Checking ONOS service - PASS (tick)
  • 123.8 Starting ONOS CLI sessions - PASS (tick)
  • 123.9 Checking ONOS nodes - PASS (tick)
  • 123.10 Checking ONOS applications - PASS (tick)
  • 123.11 Starting Mininet Topology - PASS (tick)
  • 123.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 123.13 Check whether all flow status are ADDED - PASS (tick)
  • 123.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE123_Before - PASS (tick)
  • 123.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE123_Before - PASS (tick)
  • 123.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 123.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 123.18 Check whether the flow count is bigger than 104 - PASS (tick)
  • 123.19 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • PASS (tick)
  • 123.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE123_After - PASS (tick)
  • 123.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE123_After - PASS (tick)
  • 123.22 Stopping Mininet - PASS (tick)
  • 123.23 Copying karaf logs - PASS (tick)

...

  • 163.1 Apply cell to environment - PASS (tick)
  • 163.2 Uninstalling Atomix - PASS (tick)
  • 163.3 Uninstalling ONOS package - PASS (tick)
  • 163.4 Installing Atomix - PASS (tick)
  • 163.5 Installing ONOS package - PASS (tick)
  • 163.6 Set up ONOS secure SSH - PASS (tick)
  • 163.7 Checking ONOS service - PASS (tick)
  • 163.8 Starting ONOS CLI sessions - PASS (tick)
  • 163.9 Checking ONOS nodes - PASS (tick)
  • 163.10 Checking ONOS applications - PASS (tick)
  • 163.11 Starting Mininet Topology - PASS (tick)
  • 163.12 Check whether the flow count is bigger than 106 - PASS (tick)
  • 163.13 Check whether all flow status are ADDED - PASS (tick)
  • 163.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE163_Before - PASS (tick)
  • 163.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE163_Before - PASS (tick)
  • 163.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 163.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 163.18 Check whether the flow count is bigger than 106 - PASS (tick)
  • 163.19 Check whether all flow status are ADDED - PASS (tick)
  • 163.20 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE163_After - PASS (tick)
  • 163.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE163_After - PASS (tick)
  • 163.22 Stopping Mininet - PASS (tick)
  • 163.23 Copying karaf logs - PASS (tick)

Case 173: Changing port configuration from tagged 20 to tagged 120, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 173.1 Apply cell to environment - PASS (tick)
  • 173.2 Uninstalling Atomix - PASS (tick)
  • 173.3 Uninstalling ONOS package - PASS (tick)
  • 173.4 Installing Atomix - PASS (tick)
  • 173.5 Installing ONOS package - PASS (tick)
  • 173.6 Set up ONOS secure SSH - PASS (tick)
  • 173.7 Checking ONOS service - PASS (tick)
  • 173.8 Starting ONOS CLI sessions - PASS (tick)
  • 173.9 Checking ONOS nodes - PASS (tick)
  • 173.10 Checking ONOS applications - PASS (tick)
  • 173.11 Starting Mininet Topology - PASS (tick)
  • 173.12 Check whether the flow count is bigger than 106 - PASS (tick)
  • 173.13 Check whether all flow status are ADDED - PASS (tick)
  • 173.14 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE173_Before - PASS (tick)
  • 173.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE173_Before - PASS (tick)
  • 173.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 173.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 173.18 Check whether the flow count is bigger than 106 - PASS (tick)
  • 173.19 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 173.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE173_After - PASS (tick)
  • 173.21 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE173_After - PASS (tick)
  • 173.22 Stopping Mininet - PASS (tick)
  • 173.23 Copying karaf logs - PASS (tick)

...