Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric2/lastSuccessfulBuild/artifact/SRClusterRestart_onos-1.15_20-builds_graph.jpg", alt="SRClusterRestart", style="width:525px;height:350px;border:0">

commit 0af90b91614c189b4e2d409ef068ba3a2469eb8c 7898ceda95b0e27a048c9fcee5e5c8daa332a4d4 (HEAD -] onos-1.15, origin/onos-1.15)
Author: Harshada Chaundkar [Harshada_Chaundkar@comcastJian Li [pyguni@gmail.com]
AuthorDate: Tue Jul 2 15:13:24 2019 +0000Mon Oct 5 22:36:41 2020 +0900
Commit: pier Jian Li [pier@opennetworkingpyguni@gmail.orgcom]
CommitDate: Thu Jul 11 08:25:56 2019 +0200
Fix for host store not updated when host movesMon Oct 5 22:56:34 2020 +0900

Fix: make all openstack resource name optional

Case 1: Cluster Restart test with 2x2 Leaf-spine - FAIL

...

  • 2.1 Apply cell to environment - PASS (tick)
  • 2.2 Uninstalling Atomix - PASS (tick)
  • 2.3 Uninstalling ONOS package - PASS (tick)
  • 2.4 Creating ONOS package - PASS (tick)
  • 2.5 Installing Atomix - PASS (tick)
  • 2.6 Installing ONOS package - PASS (tick)
  • 2.7 Set up ONOS secure SSH - PASS (tick)
  • 2.8 Checking ONOS service - PASS (tick)
  • 2.9 Starting ONOS CLI sessions - PASS (tick)
  • 2.10 Checking ONOS nodes - PASS (tick)
  • 2.11 Checking ONOS applications - PASS (tick)
  • 2.12 Starting Mininet Topology - PASS (tick)
  • 2.13 Check whether the flow count is bigger than 350 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 138
  • 2.14 Check whether all flow status are ADDED - PASS (tick)
  • 2.15 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.16 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2 - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 2.17 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2 - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 2.18 Killing ONOS instances with index(es): [0, 1, 2] - PASS (tick)
  • 2.19 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2_Failure - FAIL (error)
    • IP connectivity failed
  • 2.20 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_Failure - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 2.21 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_Failure - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 2.22 Recovering ONOS instances with index(es): [0, 1, 2] - PASS (tick)
  • 2.23 Checking if ONOS CLI is ready - PASS (tick)
  • 2.24 Checking if ONOS CLI is ready - PASS (tick)
  • 2.25 Checking if ONOS CLI is ready - PASS (tick)
  • 2.26 Checking ONOS nodes - PASS (tick)
  • 2.27 Check number of topology elements - PASS (tick)
  • 2.28 Check whether the flow count is bigger than 350 - PASS (tick)
  • 2.29 Check whether all flow status are ADDED - PASS (tick)
  • 2.30 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2_Failure - FAIL (error)
    • IP connectivity failed
  • 2.31 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_Failure - PASS (tick)
  • 2.32 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_Failure - PASS (tick)
  • 2.33 Stopping Mininet - PASS (tick)
  • 2.34 Copying karaf logs - PASS (tick)

...