Case 223: Changing port configuration from tagged 20 and native 10 to tagged 120 and native 10, with 2x2 leaf-spine topology and 3 ONOS instances - FAIL

  • 223.1 Apply cell to environment - PASS (tick)
  • 223.2 Uninstalling Atomix - PASS (tick)
  • 223.3 Uninstalling ONOS package - PASS (tick)
  • 223.4 Installing Atomix - PASS (tick)
  • 223.5 Installing ONOS package - PASS (tick)
  • 223.6 Set up ONOS secure SSH - PASS (tick)
  • 223.7 Checking ONOS service - PASS (tick)
  • 223.8 Starting ONOS CLI sessions - PASS (tick)
  • 223.9 Checking ONOS nodes - PASS (tick)
  • 223.10 Checking ONOS applications - PASS (tick)
  • 223.11 Starting Mininet Topology - PASS (tick)
  • 223.12 Check whether the flow count is bigger than 106 - FAIL (error)
    • Flow count looks wrong: False
  • 223.13 Check whether all flow status are ADDED - PASS (tick)
  • 223.14 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE223_Before - FAIL (error)
    • IP connectivity failed
  • 223.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE223_Before - PASS (tick)
  • 223.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - FAIL (error)
    • Flow count looks wrong.
  • 223.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - FAIL (error)
    • Flow count looks wrong.
  • 223.18 Check whether the flow count is bigger than 106 - FAIL (error)
    • Flow count looks wrong: False
  • 223.19 Check whether all flow status are ADDED - PASS (tick)
  • 223.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE223_After - FAIL (error)
    • IP connectivity failed
  • 223.21 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE223_After - PASS (tick)
  • 223.22 Stopping Mininet - PASS (tick)
  • 223.23 Copying karaf logs - PASS (tick)

Case 233: Consecutive configuration changes, with 2x2 leaf-spine topology and 3 ONOS instances - FAIL

  • 233.1 Apply cell to environment - PASS (tick)
  • 233.2 Uninstalling Atomix - PASS (tick)
  • 233.3 Uninstalling ONOS package - PASS (tick)
  • 233.4 Installing Atomix - PASS (tick)
  • 233.5 Installing ONOS package - PASS (tick)
  • 233.6 Set up ONOS secure SSH - PASS (tick)
  • 233.7 Checking ONOS service - PASS (tick)
  • 233.8 Starting ONOS CLI sessions - PASS (tick)
  • 233.9 Checking ONOS nodes - PASS (tick)
  • 233.10 Checking ONOS applications - PASS (tick)
  • 233.11 Starting Mininet Topology - PASS (tick)
  • 233.12 Check whether the flow count is bigger than 104 - FAIL (error)
    • Flow count looks wrong: False
  • 233.13 Check whether all flow status are ADDED - PASS (tick)
  • 233.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_Before - FAIL (error)
    • IP connectivity failed
  • 233.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_Before - FAIL (error)
    • IP connectivity failed
  • 233.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - FAIL (error)
    • Flow count looks wrong.
  • 233.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - FAIL (error)
    • Flow count looks wrong.
  • 233.18 Check whether the flow count of device of:0000000000000001 is bigger than 52 - FAIL (error)
    • Flow count looks wrong.
  • 233.19 Check whether the flow count of device of:0000000000000002 is bigger than 52 - FAIL (error)
    • Flow count looks wrong.
  • 233.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_1 - FAIL (error)
    • IP connectivity failed
  • 233.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_1 - PASS (tick)
  • 233.22 Check whether the flow count of device of:0000000000000001 is bigger than 52 - FAIL (error)
    • Flow count looks wrong.
  • 233.23 Check whether the flow count of device of:0000000000000002 is bigger than 52 - FAIL (error)
    • Flow count looks wrong.
  • 233.24 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_2 - FAIL (error)
    • IP connectivity failed
  • 233.25 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_2 - PASS (tick)
  • 233.26 Check whether the flow count of device of:0000000000000001 is bigger than 52 - FAIL (error)
    • Flow count looks wrong.
  • 233.27 Check whether the flow count of device of:0000000000000002 is bigger than 52 - FAIL (error)
    • Flow count looks wrong.
  • 233.28 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_3 - FAIL (error)
    • IP connectivity failed
  • 233.29 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_3 - PASS (tick)
  • 233.30 Check whether the flow count of device of:0000000000000001 is bigger than 52 - FAIL (error)
    • Flow count looks wrong.
  • 233.31 Check whether the flow count of device of:0000000000000002 is bigger than 52 - FAIL (error)
    • Flow count looks wrong.
  • 233.32 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_4 - FAIL (error)
    • IP connectivity failed
  • 233.33 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_4 - FAIL (error)
    • IP connectivity failed
  • 233.34 Check whether the flow count of device of:0000000000000001 is bigger than 52 - FAIL (error)
    • Flow count looks wrong.
  • 233.35 Check whether the flow count of device of:0000000000000002 is bigger than 52 - FAIL (error)
    • Flow count looks wrong.
  • 233.36 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_5 - FAIL (error)
    • IP connectivity failed
  • 233.37 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_5 - PASS (tick)
  • 233.38 Check whether the flow count of device of:0000000000000001 is bigger than 52 - FAIL (error)
    • Flow count looks wrong.
  • 233.39 Check whether the flow count of device of:0000000000000002 is bigger than 52 - FAIL (error)
    • Flow count looks wrong.
  • 233.40 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_6 - FAIL (error)
    • IP connectivity failed
  • 233.41 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_6 - PASS (tick)
  • 233.42 Check whether the flow count of device of:0000000000000001 is bigger than 52 - FAIL (error)
    • Flow count looks wrong.
  • 233.43 Check whether the flow count of device of:0000000000000002 is bigger than 52 - FAIL (error)
    • Flow count looks wrong.
  • 233.44 Check whether the flow count is bigger than 104 - FAIL (error)
    • Flow count looks wrong: False
  • 233.45 Check whether all flow status are ADDED - PASS (tick)
  • 233.46 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_After - FAIL (error)
    • IP connectivity failed
  • 233.47 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_After - FAIL (error)
    • IP connectivity failed
  • 233.48 Stopping Mininet - PASS (tick)
  • 233.49 Copying karaf logs - PASS (tick)

Case 243: Changing port configuration from 10.0.2.254/24 to 10.0.6.254/24, with 2x2 leaf-spine topology and 3 ONOS instances - FAIL

...

  • Flow count looks wrong: False

...

  • IP connectivity failed

...

  • Flow count looks wrong.

...

  • Flow count looks wrong.

...

  • Flow count looks wrong: False

...

  • IP connectivity failed

...