Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Published from Jenkins build: https://jenkins.onosproject.org/job/SR-pipeline-2.0/1109/

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric3/lastSuccessfulBuild/artifact/SRBridging_onos-2.0_20-builds_graph.jpg", alt="SRBridging", style="width:525px;height:350px;border:0">

commit 1e0d651c1109e6cc6704ed1b62f614ac220f956f 1990278de6f59d84cd81aebe84135050122b056b (HEAD -] onos-2.0, origin/onos-2.0)
Author: pier Thomas Vachuska [pier@opennetworkingtom@opennetworking.org]
AuthorDate: Fri Dec 21 22:02:25 2018 +0100Mon Apr 15 09:42:24 2019 -0700
Commit: Ray Milkey Thomas Vachuska [ray@opennetworkingtom@opennetworking.org]
CommitDate: Fri Jan 11 04:45:33 2019 +0000
Fix route events deliveryMon Apr 15 09:46:35 2019 -0700

Replaced test mock with existing adapter in archetypes.

Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR and 3 ONOS instances - PASS

...

  • 66.1 Apply cell to environment - PASS (tick)
  • 66.2 Uninstalling Atomix - PASS (tick)
  • 66.3 Uninstalling ONOS package - PASS (tick)
  • 66.4 Installing Atomix - PASS (tick)
  • 66.5 Installing ONOS package - PASS (tick)
  • 66.6 Set up ONOS secure SSH - PASS (tick)
  • 66.7 Checking ONOS service - PASS (tick)
  • 66.8 Starting ONOS CLI sessions - PASS (tick)
  • 66.9 Checking ONOS nodes - PASS (tick)
  • 66.10 Checking ONOS applications - PASS (tick)
  • 66.11 Starting Mininet Topology - PASS (tick)
  • 66.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 66.13 Check whether all flow status are ADDED - PASS (tick)
  • 66.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 66.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 66.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE66 - PASS (tick)
  • 66.17 Stopping Mininet - PASS (tick)
  • 66.18 Copying karaf logs - PASS (tick)

Case 67: Bridging test between two tagged hosts with different vlan id, with 2x2 leaf-spine topology and 3 ONOS instances -

...

PASS

  • 67.1 Apply cell to environment - PASS (tick)
  • 67.2 Uninstalling Atomix - PASS (tick)
  • 67.3 Uninstalling ONOS package - PASS (tick)
  • 67.4 Installing Atomix - PASS (tick)
  • 67.5 Installing ONOS package - PASS (tick)
  • 67.6 Set up ONOS secure SSH - PASS (tick)
  • 67.7 Checking ONOS service - PASS (tick)
  • 67.8 Starting ONOS CLI sessions - PASS (tick)
  • 67.9 Checking ONOS nodes - PASS (tick)
  • 67.10 Checking ONOS applications - PASS (tick)
  • 67.11 Starting Mininet Topology - PASS (tick)
  • 67.12 Check whether the flow count is bigger than 74 - FAIL (error)
    • Flow count looks wrong: False
  • PASS (tick)
  • 67.13 Check whether all flow status are ADDED - PASS (tick)
  • 67.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - FAIL (error)
    • Flow count looks wrong.
  • PASS (tick)
  • 67.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - FAIL (error)
  • Flow count looks wrong.
  • PASS (tick)
  • 67.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE67 - PASS (tick)
  • 67.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE67 - PASS (tick)
  • 67.18 Stopping Mininet - PASS (tick)
  • 67.19 Copying karaf logs - PASS (tick)

...