Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
HTML |
---|
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric3/lastSuccessfulBuild/artifact/SRBridging_onos-2.0_20-builds_graph.jpg", alt="SRBridging", style="width:525px;height:350px;border:0"> |
commit a10f675028d2b297fb63b1fd4af1aade37801156 1990278de6f59d84cd81aebe84135050122b056b (HEAD -] onos-2.0, origin/onos-2.0)
Author: Carmelo Cascone Thomas Vachuska [carmelo@opennetworkingtom@opennetworking.org]
AuthorDate: Tue Sep 11 Mon Apr 15 09:1742:23 2018 24 2019 -0700
Commit: Carmelo Cascone Thomas Vachuska [carmelo@opennetworkingtom@opennetworking.org]
CommitDate: Mon Jan 14 13:55:26 Apr 15 09:46:35 2019 -0800
ONOS-7887 Rename action profile-related entities0700
Replaced test mock with existing adapter in archetypes.
Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR and 3 ONOS instances - PASS
...
- 27.1 Apply cell to environment - PASS
- 27.2 Uninstalling Atomix - PASS
- 27.3 Uninstalling ONOS package - PASS
- 27.4 Installing Atomix - PASS
- 27.5 Installing ONOS package - PASS
- 27.6 Set up ONOS secure SSH - PASS
- 27.7 Checking ONOS service - PASS
- 27.8 Starting ONOS CLI sessions - PASS
- 27.9 Checking ONOS nodes - PASS
- 27.10 Checking ONOS applications - PASS
- 27.11 Starting Mininet Topology - PASS
- 27.12 Check whether the flow count is bigger than 74 - PASS
- 27.13 Check whether all flow status are ADDED - PASS
- 27.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 27.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 27.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE27 - PASS
- 27.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE27 - PASS
- 27.18 Stopping Mininet - PASS
- 27.19 Copying karaf logs - PASS
Case 28: Bridging test between two untagged hosts on vlan-native port, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances -
...
PASS
- 28.1 Apply cell to environment - PASS
- 28.2 Uninstalling Atomix - PASS
- 28.3 Uninstalling ONOS package - PASS
- 28.4 Installing Atomix - PASS
- 28.5 Installing ONOS package - PASS
- 28.6 Set up ONOS secure SSH - PASS
- 28.7 Checking ONOS service - PASS
- 28.8 Starting ONOS CLI sessions - PASS
- 28.9 Checking ONOS nodes - PASS
- 28.10 Checking ONOS applications - PASS
- 28.11 Starting Mininet Topology - PASS
- 28.12 Check whether the flow count is bigger than 212 - PASS
- 28.13 Check whether all flow status are ADDED - PASS
- 28.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 28.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 28.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS
- 28.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - FAIL
- Flow count looks wrong.
- PASS
- 28.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE28 - PASS
- 28.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE28 - FAIL IP connectivity failed
- PASS
- 28.20 Stopping Mininet - PASS
- 28.21 Copying karaf logs - PASS
...