Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
HTML |
---|
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric3/lastSuccessfulBuild/artifact/SRBridging_onos-2.0_20-builds_graph.jpg", alt="SRBridging", style="width:525px;height:350px;border:0"> |
commit 9d3ad8b9d8d8cf9dc6f6c9345757a365b09ff0db 1990278de6f59d84cd81aebe84135050122b056b (HEAD -] onos-2.0, origin/onos-2.0)
Author: hiroki Thomas Vachuska [hirokitom@opennetworking.okui@gmail.comorg]
AuthorDate: Sun Jan 20 20:05:51 2019 -0800Mon Apr 15 09:42:24 2019 -0700
Commit: Andrea Campanella Thomas Vachuska [andrea@opennetworkingtom@opennetworking.org]
CommitDate: Fri Jan 25 08:27:17 2019 +0000
ONOS-7867 FlowRuleProgrammable driver for OpenConfig Cassini
--
(cherry picked from commit 337c5526d17dff0a1dc5114b015414afc9c221d2)Mon Apr 15 09:46:35 2019 -0700
Replaced test mock with existing adapter in archetypes.
Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR and 3 ONOS instances - PASS
...
- 6.1 Apply cell to environment - PASS
- 6.2 Uninstalling Atomix - PASS
- 6.3 Uninstalling ONOS package - PASS
- 6.4 Installing Atomix - PASS
- 6.5 Installing ONOS package - PASS
- 6.6 Set up ONOS secure SSH - PASS
- 6.7 Checking ONOS service - PASS
- 6.8 Starting ONOS CLI sessions - PASS
- 6.9 Checking ONOS nodes - PASS
- 6.10 Checking ONOS applications - PASS
- 6.11 Starting Mininet Topology - PASS
- 6.12 Check whether the flow count is bigger than 74 - PASS
- 6.13 Check whether all flow status are ADDED - PASS
- 6.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 6.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 6.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE6 - PASS
- 6.17 Stopping Mininet - PASS
- 6.18 Copying karaf logs - PASS
Case 7: Bridging test between two untagged hosts on vlan-untagged port, with 2x2 leaf-spine topology and 3 ONOS instances -
...
PASS
- 7.1 Apply cell to environment - PASS
- 7.2 Uninstalling Atomix - PASS
- 7.3 Uninstalling ONOS package - PASS
- 7.4 Installing Atomix - PASS
- 7.5 Installing ONOS package - PASS
- 7.6 Set up ONOS secure SSH - PASS
- 7.7 Checking ONOS service - PASS
- 7.8 Starting ONOS CLI sessions - PASS
- 7.9 Checking ONOS nodes - PASS
- 7.10 Checking ONOS applications - PASS
- 7.11 Starting Mininet Topology - PASS
- 7.12 Check whether the flow count is bigger than 74 - PASS
- 7.13 Check whether all flow status are ADDED - PASS
- 7.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - FAIL Flow count looks wrong: 16
- PASS
- 7.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - FAIL
- Flow count looks wrong: 27
- PASS
- 7.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE7 - FAIL
- IP connectivity failed
- PASS
- 7.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE7 - FAIL
- IP connectivity failed
- PASS
- 7.18 Stopping Mininet - PASS
- 7.19 Copying karaf logs - PASS
...
- 67.1 Apply cell to environment - PASS
- 67.2 Uninstalling Atomix - PASS
- 67.3 Uninstalling ONOS package - PASS
- 67.4 Installing Atomix - PASS
- 67.5 Installing ONOS package - PASS
- 67.6 Set up ONOS secure SSH - PASS
- 67.7 Checking ONOS service - PASS
- 67.8 Starting ONOS CLI sessions - PASS
- 67.9 Checking ONOS nodes - PASS
- 67.10 Checking ONOS applications - PASS
- 67.11 Starting Mininet Topology - PASS
- 67.12 Check whether the flow count is bigger than 74 - PASS
- 67.13 Check whether all flow status are ADDED - PASS
- 67.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 67.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 67.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE67 - PASS
- 67.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE67 - PASS
- 67.18 Stopping Mininet - PASS
- 67.19 Copying karaf logs - PASS
Case 68: Bridging test between two tagged hosts with different vlan id, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances -
...
PASS
- 68.1 Apply cell to environment - PASS
- 68.2 Uninstalling Atomix - PASS
- 68.3 Uninstalling ONOS package - PASS
- 68.4 Installing Atomix - PASS
- 68.5 Installing ONOS package - PASS
- 68.6 Set up ONOS secure SSH - PASS
- 68.7 Checking ONOS service - PASS
- 68.8 Starting ONOS CLI sessions - PASS
- 68.9 Checking ONOS nodes - PASS
- 68.10 Checking ONOS applications - PASS
- 68.11 Starting Mininet Topology - PASS
- 68.12 Check whether the flow count is bigger than 212 - FAIL Flow count looks wrong: 18
- PASS
- 68.13 Check whether all flow status are ADDED - PASS
- 68.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - FAIL Flow count looks wrong: 3
- PASS
- 68.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - FAIL
- Flow count looks wrong: 3
- PASS
- 68.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - FAIL Flow count looks wrong: 3
- PASS
- 68.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - FAIL Flow count looks wrong: 3
- PASS
- 68.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE68 - PASS
- 68.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE68 - PASS
- 68.20 Stopping Mininet - PASS
- 68.21 Copying karaf logs - PASS
...