Comment: Published from Jenkins build: https://jenkins.onosproject.org/job/SR-pipeline-2.0/1109/

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric3/lastSuccessfulBuild/artifact/SRBridging_onos-2.0_20-builds_graph.jpg", alt="SRBridging", style="width:525px;height:350px;border:0">

commit 6d1cb159fd06efc94de8d88149669ecacc26ad5b 1990278de6f59d84cd81aebe84135050122b056b (HEAD -] onos-2.0, origin/onos-2.0)
Author: Carmelo Cascone Thomas Vachuska [carmelo@opennetworkingtom@opennetworking.org]
AuthorDate: Mon Feb 4 23:11:26 Apr 15 09:42:24 2019 -08000700
Commit: Carmelo Cascone Thomas Vachuska [carmelo@opennetworkingtom@opennetworking.org]
CommitDate: Tue Feb 5 22:29:12 2019 +0000
Enhanced gRPC call logging
--
(cherry picked from commit 73f4530c389477352c6ea92d42c94d46fa3f0630)Mon Apr 15 09:46:35 2019 -0700

Replaced test mock with existing adapter in archetypes.

Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR and 3 ONOS instances - PASS

...

  • 27.1 Apply cell to environment - PASS (tick)
  • 27.2 Uninstalling Atomix - PASS (tick)
  • 27.3 Uninstalling ONOS package - PASS (tick)
  • 27.4 Installing Atomix - PASS (tick)
  • 27.5 Installing ONOS package - PASS (tick)
  • 27.6 Set up ONOS secure SSH - PASS (tick)
  • 27.7 Checking ONOS service - PASS (tick)
  • 27.8 Starting ONOS CLI sessions - PASS (tick)
  • 27.9 Checking ONOS nodes - PASS (tick)
  • 27.10 Checking ONOS applications - PASS (tick)
  • 27.11 Starting Mininet Topology - PASS (tick)
  • 27.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 27.13 Check whether all flow status are ADDED - PASS (tick)
  • 27.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 27.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 27.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE27 - PASS (tick)
  • 27.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE27 - PASS (tick)
  • 27.18 Stopping Mininet - PASS (tick)
  • 27.19 Copying karaf logs - PASS (tick)

Case 28: Bridging test between two untagged hosts on vlan-native port, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances -

...

PASS

  • 28.1 Apply cell to environment - PASS (tick)
  • 28.2 Uninstalling Atomix - PASS (tick)
  • 28.3 Uninstalling ONOS package - PASS (tick)
  • 28.4 Installing Atomix - PASS (tick)
  • 28.5 Installing ONOS package - PASS (tick)
  • 28.6 Set up ONOS secure SSH - PASS (tick)
  • 28.7 Checking ONOS service - PASS (tick)
  • 28.8 Starting ONOS CLI sessions - PASS (tick)
  • 28.9 Checking ONOS nodes - PASS (tick)
  • 28.10 Checking ONOS applications - PASS (tick)
  • 28.11 Starting Mininet Topology - PASS (tick)
  • 28.12 Check whether the flow count is bigger than 212 - FAIL (error)
  • Flow count looks wrong: 18
  • PASS (tick)
  • 28.13 Check whether all flow status are ADDED - PASS (tick)
  • 28.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - FAIL (error)
    • Flow count looks wrong: 3
  • PASS (tick)
  • 28.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - FAIL (error)
  • Flow count looks wrong: 3
  • PASS (tick)
  • 28.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - FAIL (error)
  • Flow count looks wrong: 3
  • PASS (tick)
  • 28.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - FAIL (error)
  • Flow count looks wrong: 3
  • PASS (tick)
  • 28.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE28 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 28.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE28 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 28.20 Stopping Mininet - PASS (tick)
  • 28.21 Copying karaf logs - PASS (tick)

...

  • 65.1 Apply cell to environment - PASS (tick)
  • 65.2 Uninstalling Atomix - PASS (tick)
  • 65.3 Uninstalling ONOS package - PASS (tick)
  • 65.4 Installing Atomix - PASS (tick)
  • 65.5 Installing ONOS package - PASS (tick)
  • 65.6 Set up ONOS secure SSH - PASS (tick)
  • 65.7 Checking ONOS service - PASS (tick)
  • 65.8 Starting ONOS CLI sessions - PASS (tick)
  • 65.9 Checking ONOS nodes - PASS (tick)
  • 65.10 Checking ONOS applications - PASS (tick)
  • 65.11 Starting Mininet Topology - PASS (tick)
  • 65.12 Check whether the flow count is bigger than 28 - PASS (tick)
  • 65.13 Check whether all flow status are ADDED - PASS (tick)
  • 65.14 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS (tick)
  • 65.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE65 - PASS (tick)
  • 65.16 Stopping Mininet - PASS (tick)
  • 65.17 Copying karaf logs - PASS (tick)

Case 66: Bridging test between two tagged hosts with different vlan id, with dual-homed ToR and 3 ONOS instances -

...

PASS

  • 66.1 Apply cell to environment - PASS (tick)
  • 66.2 Uninstalling Atomix - PASS (tick)
  • 66.3 Uninstalling ONOS package - PASS (tick)
  • 66.4 Installing Atomix - PASS (tick)
  • 66.5 Installing ONOS package - PASS (tick)
  • 66.6 Set up ONOS secure SSH - PASS (tick)
  • 66.7 Checking ONOS service - PASS (tick)
  • 66.8 Starting ONOS CLI sessions - PASS (tick)
  • 66.9 Checking ONOS nodes - PASS (tick)
  • 66.10 Checking ONOS applications - PASS (tick)
  • 66.11 Starting Mininet Topology - PASS (tick)
  • 66.12 Check whether the flow count is bigger than 74 - FAIL (error)
  • Flow count looks wrong: 6
  • PASS (tick)
  • 66.13 Check whether all flow status are ADDED - PASS (tick)
  • 66.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - FAIL (error)
    • Flow count looks wrong: 3
  • PASS (tick)
  • 66.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - FAIL (error)
    • Flow count looks wrong: 3
  • PASS (tick)
  • 66.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE66 - PASS (tick)
  • 66.17 Stopping Mininet - PASS (tick)
  • 66.18 Copying karaf logs - PASS (tick)

...

  • 77.1 Apply cell to environment - PASS (tick)
  • 77.2 Uninstalling Atomix - PASS (tick)
  • 77.3 Uninstalling ONOS package - PASS (tick)
  • 77.4 Installing Atomix - PASS (tick)
  • 77.5 Installing ONOS package - PASS (tick)
  • 77.6 Set up ONOS secure SSH - PASS (tick)
  • 77.7 Checking ONOS service - PASS (tick)
  • 77.8 Starting ONOS CLI sessions - PASS (tick)
  • 77.9 Checking ONOS nodes - PASS (tick)
  • 77.10 Checking ONOS applications - PASS (tick)
  • 77.11 Starting Mininet Topology - PASS (tick)
  • 77.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 77.13 Check whether all flow status are ADDED - PASS (tick)
  • 77.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 77.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 77.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE77 - PASS (tick)
  • 77.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE77 - PASS (tick)
  • 77.18 Stopping Mininet - PASS (tick)
  • 77.19 Copying karaf logs - PASS (tick)

Case 78: Bridging test between untagged and tagged hosts with different vlan id, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances -

...

PASS

  • 78.1 Apply cell to environment - PASS (tick)
  • 78.2 Uninstalling Atomix - PASS (tick)
  • 78.3 Uninstalling ONOS package - PASS (tick)
  • 78.4 Installing Atomix - PASS (tick)
  • 78.5 Installing ONOS package - PASS (tick)
  • 78.6 Set up ONOS secure SSH - PASS (tick)
  • 78.7 Checking ONOS service - PASS (tick)
  • 78.8 Starting ONOS CLI sessions - PASS (tick)
  • 78.9 Checking ONOS nodes - PASS (tick)
  • 78.10 Checking ONOS applications - PASS (tick)
  • 78.11 Starting Mininet Topology - PASS (tick)
  • 78.12 Check whether the flow count is bigger than 212 - FAIL (error)
  • Flow count looks wrong: 18
  • PASS (tick)
  • 78.13 Check whether all flow status are ADDED - PASS (tick)
  • 78.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - FAIL (error)
  • Flow count looks wrong: 3
  • PASS (tick)
  • 78.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - FAIL (error)
    • Flow count looks wrong: 3
  • PASS (tick)
  • 78.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - FAIL (error)
  • Flow count looks wrong: 3
  • PASS (tick)
  • 78.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - FAIL (error)
  • Flow count looks wrong: 3
  • PASS (tick)
  • 78.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE78 - PASS (tick)
  • 78.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE78 - PASS (tick)
  • 78.20 Stopping Mininet - PASS (tick)