Comment: Published from Jenkins build: https://jenkins.onosproject.org/job/SR-pipeline-2.0/1109/

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric3/lastSuccessfulBuild/artifact/SRBridging_onos-2.0_20-builds_graph.jpg", alt="SRBridging", style="width:525px;height:350px;border:0">

commit a828e07a3b08c3b20ee71d1210ca56be98a487bb 1990278de6f59d84cd81aebe84135050122b056b (HEAD -] onos-2.0, origin/onos-2.0)
Author: hiroki Thomas Vachuska [hirokitom@opennetworking.okui@gmail.comorg]
AuthorDate: Fri Feb Mon Apr 15 1309:1742:26 24 2019 -08000700
Commit: Andrea Campanella Thomas Vachuska [andrea@opennetworkingtom@opennetworking.org]
CommitDate: Sat Feb 16 Mon Apr 15 09:4846:04 35 2019 +0000
[odtn] Fix bug in order to delete lower-connections properly when connectivity deleted
--
(cherry picked from commit a5ae3bd1e587df285c7dd5fed3d90519d07a7616)-0700

Replaced test mock with existing adapter in archetypes.

Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR and 3 ONOS instances - PASS

...

  • 67.1 Apply cell to environment - PASS (tick)
  • 67.2 Uninstalling Atomix - PASS (tick)
  • 67.3 Uninstalling ONOS package - PASS (tick)
  • 67.4 Installing Atomix - PASS (tick)
  • 67.5 Installing ONOS package - PASS (tick)
  • 67.6 Set up ONOS secure SSH - PASS (tick)
  • 67.7 Checking ONOS service - PASS (tick)
  • 67.8 Starting ONOS CLI sessions - PASS (tick)
  • 67.9 Checking ONOS nodes - PASS (tick)
  • 67.10 Checking ONOS applications - PASS (tick)
  • 67.11 Starting Mininet Topology - PASS (tick)
  • 67.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 67.13 Check whether all flow status are ADDED - PASS (tick)
  • 67.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 67.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 67.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE67 - PASS (tick)
  • 67.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE67 - PASS (tick)
  • 67.18 Stopping Mininet - PASS (tick)
  • 67.19 Copying karaf logs - PASS (tick)

Case 68: Bridging test between two tagged hosts with different vlan id, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances -

...

PASS

  • 68.1 Apply cell to environment - PASS (tick)
  • 68.2 Uninstalling Atomix - PASS (tick)
  • 68.3 Uninstalling ONOS package - PASS (tick)
  • 68.4 Installing Atomix - PASS (tick)
  • 68.5 Installing ONOS package - PASS (tick)
  • 68.6 Set up ONOS secure SSH - PASS (tick)
  • 68.7 Checking ONOS service - PASS (tick)
  • 68.8 Starting ONOS CLI sessions - PASS (tick)
  • 68.9 Checking ONOS nodes - PASS (tick)
  • 68.10 Checking ONOS applications - PASS (tick)
  • 68.11 Starting Mininet Topology - PASS (tick)
  • 68.12 Check whether the flow count is bigger than 212 - FAIL (error)
  • Flow count looks wrong: 18
  • PASS (tick)
  • 68.13 Check whether all flow status are ADDED - PASS (tick)
  • 68.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - FAIL (error)
  • Flow count looks wrong: 3
  • PASS (tick)
  • 68.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - FAIL (error)
  • Flow count looks wrong: 3
  • PASS (tick)
  • 68.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - FAIL (error)
    • Flow count looks wrong: 3
  • PASS (tick)
  • 68.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - FAIL (error)
  • Flow count looks wrong: 3
  • PASS (tick)
  • 68.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE68 - PASS (tick)
  • 68.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE68 - PASS (tick)
  • 68.20 Stopping Mininet - PASS (tick)
  • 68.21 Copying karaf logs - PASS (tick)

...