Comment: Published from Jenkins build: https://jenkins.onosproject.org/job/SR-pipeline-2.0/1109/

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric3/lastSuccessfulBuild/artifact/SRBridging_onos-2.0_20-builds_graph.jpg", alt="SRBridging", style="width:525px;height:350px;border:0">

commit fa6af0cdbd071b19bf9a1d731bc9419135b060df 1990278de6f59d84cd81aebe84135050122b056b (HEAD -] onos-2.0, origin/onos-2.0)
Author: Ray Milkey Thomas Vachuska [ray@opennetworkingtom@opennetworking.org]
AuthorDate: Fri Mar 22 16: Mon Apr 15 09:42:24 :38 2019 -0700
Commit: Ray Milkey Thomas Vachuska [ray@opennetworkingtom@opennetworking.org]
CommitDate: Fri Mar 22 16:24:38 Mon Apr 15 09:46:35 2019 -0700
Implement static component properties - passed through without modification
Replaced test mock with existing adapter in archetypes.

Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR and 3 ONOS instances - PASS

...

  • 6.1 Apply cell to environment - PASS (tick)
  • 6.2 Uninstalling Atomix - PASS (tick)
  • 6.3 Uninstalling ONOS package - PASS (tick)
  • 6.4 Installing Atomix - PASS (tick)
  • 6.5 Installing ONOS package - PASS (tick)
  • 6.6 Set up ONOS secure SSH - PASS (tick)
  • 6.7 Checking ONOS service - PASS (tick)
  • 6.8 Starting ONOS CLI sessions - PASS (tick)
  • 6.9 Checking ONOS nodes - PASS (tick)
  • 6.10 Checking ONOS applications - PASS (tick)
  • 6.11 Starting Mininet Topology - PASS (tick)
  • 6.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 6.13 Check whether all flow status are ADDED - PASS (tick)
  • 6.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 6.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 6.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE6 - PASS (tick)
  • 6.17 Stopping Mininet - PASS (tick)
  • 6.18 Copying karaf logs - PASS (tick)

Case 7: Bridging test between two untagged hosts on vlan-untagged port, with 2x2 leaf-spine topology and 3 ONOS instances -

...

PASS

  • 7.1 Apply cell to environment - PASS (tick)
  • 7.2 Uninstalling Atomix - PASS (tick)
  • 7.3 Uninstalling ONOS package - PASS (tick)
  • 7.4 Installing Atomix - PASS (tick)
  • 7.5 Installing ONOS package - PASS (tick)
  • 7.6 Set up ONOS secure SSH - PASS (tick)
  • 7.7 Checking ONOS service - PASS (tick)
  • 7.8 Starting ONOS CLI sessions - PASS (tick)
  • 7.9 Checking ONOS nodes - PASS (tick)
  • 7.10 Checking ONOS applications - PASS (tick)
  • 7.11 Starting Mininet Topology - PASS (tick)
  • 7.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 7.13 Check whether all flow status are ADDED - PASS (tick)
  • 7.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 7.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 7.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE7 - PASS (tick)
  • 7.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE7 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 7.18 Stopping Mininet - PASS (tick)
  • 7.19 Copying karaf logs - PASS (tick)

...

  • 46.1 Apply cell to environment - PASS (tick)
  • 46.2 Uninstalling Atomix - PASS (tick)
  • 46.3 Uninstalling ONOS package - PASS (tick)
  • 46.4 Installing Atomix - PASS (tick)
  • 46.5 Installing ONOS package - PASS (tick)
  • 46.6 Set up ONOS secure SSH - PASS (tick)
  • 46.7 Checking ONOS service - PASS (tick)
  • 46.8 Starting ONOS CLI sessions - PASS (tick)
  • 46.9 Checking ONOS nodes - PASS (tick)
  • 46.10 Checking ONOS applications - PASS (tick)
  • 46.11 Starting Mininet Topology - PASS (tick)
  • 46.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 46.13 Check whether all flow status are ADDED - PASS (tick)
  • 46.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 46.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 46.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE46 - PASS (tick)
  • 46.17 Stopping Mininet - PASS (tick)
  • 46.18 Copying karaf logs - PASS (tick)

Case 47: Bridging test between untagged host and tagged host, with 2x2 leaf-spine topology and 3 ONOS instances -

...

PASS

  • 47.1 Apply cell to environment - PASS (tick)
  • 47.2 Uninstalling Atomix - PASS (tick)
  • 47.3 Uninstalling ONOS package - PASS (tick)
  • 47.4 Installing Atomix - PASS (tick)
  • 47.5 Installing ONOS package - PASS (tick)
  • 47.6 Set up ONOS secure SSH - PASS (tick)
  • 47.7 Checking ONOS service - PASS (tick)
  • 47.8 Starting ONOS CLI sessions - PASS (tick)
  • 47.9 Checking ONOS nodes - PASS (tick)
  • 47.10 Checking ONOS applications - PASS (tick)
  • 47.11 Starting Mininet Topology - PASS (tick)
  • 47.12 Check whether the flow count is bigger than 74 - FAIL (error)
  • Flow count looks wrong: 12
  • PASS (tick)
  • 47.13 Check whether all flow status are ADDED - PASS (tick)
  • 47.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - FAIL (error)
    • Flow count looks wrong: 3
  • PASS (tick)
  • 47.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - FAIL (error)
  • Flow count looks wrong: 3
  • PASS (tick)
  • 47.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE47 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 47.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE47 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 47.18 Stopping Mininet - PASS (tick)
  • 47.19 Copying karaf logs - PASS (tick)

...