Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
HTML |
---|
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric3/lastSuccessfulBuild/artifact/SRBridging_onos-2.0_20-builds_graph.jpg", alt="SRBridging", style="width:525px;height:350px;border:0"> |
commit f40d2d42352bd657fa4124fb7ba4171d0d61a2fe a828e07a3b08c3b20ee71d1210ca56be98a487bb (HEAD -] onos-2.0, origin/onos-2.0)
Author: Ray Milkey [ray@opennetworking.orghiroki [hiroki.okui@gmail.com]
AuthorDate: Fri Feb 15 1013:0017:57 26 2019 -0800
Commit: Ray Milkey Andrea Campanella [ray@opennetworkingandrea@opennetworking.org]
CommitDate: Fri Sat Feb 16 15 12:4248:22 2019 -0800
Change JDK container for Docker build04 2019 +0000
[odtn] Fix bug in order to delete lower-connections properly when connectivity deleted
--
(cherry picked from commit a5ae3bd1e587df285c7dd5fed3d90519d07a7616)
Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR and 3 ONOS instances - PASS
...
- 7.1 Apply cell to environment - PASS
- 7.2 Uninstalling Atomix - PASS
- 7.3 Uninstalling ONOS package - PASS
- 7.4 Installing Atomix - PASS
- 7.5 Installing ONOS package - PASS
- 7.6 Set up ONOS secure SSH - PASS
- 7.7 Checking ONOS service - PASS
- 7.8 Starting ONOS CLI sessions - PASS
- 7.9 Checking ONOS nodes - PASS
- 7.10 Checking ONOS applications - PASS
- 7.11 Starting Mininet Topology - PASS
- 7.12 Check whether the flow count is bigger than 74 - PASS
- 7.13 Check whether all flow status are ADDED - PASS
- 7.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 7.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 7.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE7 - PASS
- 7.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE7 - PASS
- 7.18 Stopping Mininet - PASS
- 7.19 Copying karaf logs - PASS
Case 8: Bridging test between two untagged hosts on vlan-untagged port, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances -
...
PASS
- 8.1 Apply cell to environment - PASS
- 8.2 Uninstalling Atomix - PASS
- 8.3 Uninstalling ONOS package - PASS
- 8.4 Installing Atomix - PASS
- 8.5 Installing ONOS package - PASS
- 8.6 Set up ONOS secure SSH - PASS
- 8.7 Checking ONOS service - PASS
- 8.8 Starting ONOS CLI sessions - PASS
- 8.9 Checking ONOS nodes - PASS
- 8.10 Checking ONOS applications - PASS
- 8.11 Starting Mininet Topology - PASS
- 8.12 Check whether the flow count is bigger than 212 - FAIL Flow count looks wrong: 18
- PASS
- 8.13 Check whether all flow status are ADDED - PASS
- 8.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - FAIL
- Flow count looks wrong: 3
- PASS
- 8.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - FAIL
- Flow count looks wrong: 3
- PASS
- 8.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - FAIL
- Flow count looks wrong: 3
- PASS
- 8.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - FAIL Flow count looks wrong: 3
- PASS
- 8.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE8 - FAIL IP connectivity failed
- PASS
- 8.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE8 - FAIL IP connectivity failed
- PASS
- 8.20 Stopping Mininet - PASS
- 8.21 Copying karaf logs - PASS
...
- 58.1 Apply cell to environment - PASS
- 58.2 Uninstalling Atomix - PASS
- 58.3 Uninstalling ONOS package - PASS
- 58.4 Installing Atomix - PASS
- 58.5 Installing ONOS package - PASS
- 58.6 Set up ONOS secure SSH - PASS
- 58.7 Checking ONOS service - PASS
- 58.8 Starting ONOS CLI sessions - PASS
- 58.9 Checking ONOS nodes - PASS
- 58.10 Checking ONOS applications - PASS
- 58.11 Starting Mininet Topology - PASS
- 58.12 Check whether the flow count is bigger than 212 - PASS
- 58.13 Check whether all flow status are ADDED - PASS
- 58.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 58.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 58.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS
- 58.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS
- 58.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE58 - PASS
- 58.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE58 - PASS
- 58.20 Stopping Mininet - PASS
- 58.21 Copying karaf logs - PASS
Case 65: Bridging test between two tagged hosts with different vlan id, with single ToR and 3 ONOS instances -
...
PASS
- 65.1 Apply cell to environment - PASS
- 65.2 Uninstalling Atomix - PASS
- 65.3 Uninstalling ONOS package - PASS
- 65.4 Installing Atomix - PASS
- 65.5 Installing ONOS package - PASS
- 65.6 Set up ONOS secure SSH - PASS
- 65.7 Checking ONOS service - PASS
- 65.8 Starting ONOS CLI sessions - PASS
- 65.9 Checking ONOS nodes - PASS
- 65.10 Checking ONOS applications - PASS
- 65.11 Starting Mininet Topology - PASS
- 65.12 Check whether the flow count is bigger than 28 - FAIL
- Flow count looks wrong: 3
- PASS
- 65.13 Check whether all flow status are ADDED - PASS
- 65.14 Check whether the flow count of device of:0000000000000001 is bigger than 28 - FAIL
- Flow count looks wrong: 3
- PASS
- 65.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE65 - PASS
- 65.16 Stopping Mininet - PASS
- 65.17 Copying karaf logs - PASS
...
- 67.1 Apply cell to environment - PASS
- 67.2 Uninstalling Atomix - PASS
- 67.3 Uninstalling ONOS package - PASS
- 67.4 Installing Atomix - PASS
- 67.5 Installing ONOS package - PASS
- 67.6 Set up ONOS secure SSH - PASS
- 67.7 Checking ONOS service - PASS
- 67.8 Starting ONOS CLI sessions - PASS
- 67.9 Checking ONOS nodes - PASS
- 67.10 Checking ONOS applications - PASS
- 67.11 Starting Mininet Topology - PASS
- 67.12 Check whether the flow count is bigger than 74 - PASS
- 67.13 Check whether all flow status are ADDED - PASS
- 67.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 67.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 67.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE67 - PASS
- 67.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE67 - PASS
- 67.18 Stopping Mininet - PASS
- 67.19 Copying karaf logs - PASS
Case 68: Bridging test between two tagged hosts with different vlan id, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances -
...
FAIL
- 68.1 Apply cell to environment - PASS
- 68.2 Uninstalling Atomix - PASS
- 68.3 Uninstalling ONOS package - PASS
- 68.4 Installing Atomix - PASS
- 68.5 Installing ONOS package - PASS
- 68.6 Set up ONOS secure SSH - PASS
- 68.7 Checking ONOS service - PASS
- 68.8 Starting ONOS CLI sessions - PASS
- 68.9 Checking ONOS nodes - PASS
- 68.10 Checking ONOS applications - PASS
- 68.11 Starting Mininet Topology - PASS
- 68.12 Check whether the flow count is bigger than 212 - PASS FAIL
- Flow count looks wrong: 18
- 68.13 Check whether all flow status are ADDED - PASS
- 68.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS FAIL
- Flow count looks wrong: 3
- 68.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS FAIL
- Flow count looks wrong: 3
- 68.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS FAIL
- Flow count looks wrong: 3
- 68.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS FAIL
- Flow count looks wrong: 3
- 68.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE68 - PASS
- 68.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE68 - PASS
- 68.20 Stopping Mininet - PASS
- 68.21 Copying karaf logs - PASS
...