Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
HTML |
---|
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric2/lastSuccessfulBuild/artifact/SRDynamicConf_onos-1.15_20-builds_graph.jpg", alt="SRDynamicConf", style="width:525px;height:350px;border:0"> |
commit a8f2602a2763fb32e6e9b015830531c60178ccb9 8b468c2d7478f95c45e70307c42ade900d89bb3d (HEAD -] onos-1.15, origin/onos-1.15)
Author: Charles Chan [rascov@gmail.com]
AuthorDate: Tue Nov 27 Fri Dec 21 13:3355:33 29 2018 +-0800
Commit: Charles Chan [rascov@gmail.com]
CommitDate: Wed Fri Dec 19 1521 18:1601:18 15 2018 -0800
Address StackOverflow by offloading cache listener to a separate thread
Unit test fix - timeout is not correctly set in parallel execution environment
Case 13: Changing port configuration from untagged 10 to tagged 10, with 2x2 leaf-spine topology and 3 ONOS instances - PASS
...
- 53.1 Apply cell to environment - PASS
- 53.2 Uninstalling Atomix - PASS
- 53.3 Uninstalling ONOS package - PASS
- 53.4 Installing Atomix - PASS
- 53.5 Installing ONOS package - PASS
- 53.6 Set up ONOS secure SSH - PASS
- 53.7 Checking ONOS service - PASS
- 53.8 Starting ONOS CLI sessions - PASS
- 53.9 Checking ONOS nodes - PASS
- 53.10 Checking ONOS applications - PASS
- 53.11 Starting Mininet Topology - PASS
- 53.12 Check whether the flow count is bigger than 104 - PASS
- 53.13 Check whether all flow status are ADDED - PASS
- 53.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE53_Before - PASS
- 53.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE53_Before - PASS
- 53.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 53.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 53.18 Check whether the flow count is bigger than 104 - PASS
- 53.19 Check whether all flow status are ADDED - PASS
- 53.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE53_After - PASS
- 53.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE53_After - PASS
- 53.22 Stopping Mininet - PASS
- 53.23 Copying karaf logs - PASS
Case 63: Changing port configuration from untagged 10 to tagged 120 with native 110, with 2x2 leaf-spine topology and 3 ONOS instances -
...
PASS
- 63.1 Apply cell to environment - PASS
- 63.2 Uninstalling Atomix - PASS
- 63.3 Uninstalling ONOS package - PASS
- 63.4 Installing Atomix - PASS
- 63.5 Installing ONOS package - PASS
- 63.6 Set up ONOS secure SSH - PASS
- 63.7 Checking ONOS service - PASS
- 63.8 Starting ONOS CLI sessions - PASS
- 63.9 Checking ONOS nodes - PASS
- 63.10 Checking ONOS applications - PASS
- 63.11 Starting Mininet Topology - PASS
- 63.12 Check whether the flow count is bigger than 104 - PASS
- 63.13 Check whether all flow status are ADDED - PASS
- 63.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE63_Before - PASS
- 63.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE63_Before - PASS
- 63.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 63.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 63.18 Check whether the flow count is bigger than 104 - PASS
- 63.19 Check whether all flow status are ADDED - FAIL Flow status is wrong!
- PASS
- 63.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE63_After - PASS
- 63.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE63_After - PASS
- 63.22 Stopping Mininet - PASS
- 63.23 Copying karaf logs - PASS
...